Laserfiche WebLink
37' 8-3/4" <br /> —172�" [ 6 181 1/2" <br /> Z 130130 3 4• I 48'• ,n.,' '1a 140 1/4" 140 1/4" <br /> 0 <br /> 1= I 49 1/2 491/2-, <br /> F- <br /> ,- :2 -:4]-,r ¢ ,A ( TYP.) ,JI, <br /> Z � <br /> Q 1'L <br /> Zp I 401 i I <br /> 0 <br /> nw0 <br /> o <br /> Z _ Z O y C <br /> to <br /> CONTAINMENT C <br /> 1' CONTAINMENT Zz � XERXES d•4=� R e " XE COLLAR " r� <br /> = tea FIBERGLASS s q LASS FIBERG d <br /> 3 _ V) i ill 0 r� Q C C r <br /> ~w ACTUAL CAPACITY - 19,730 GALLONS ,Te ��, TANK WEIGHT ACTUAL CAPACITY '�""� Q <br /> it AL CAPACITY <br /> ca <br /> L-j3 U1 TANK WEIGHT - 8,210 LBS. ( ' <br /> U) � w m^ � ,369 GALLONS 8,350 LBS. 10,180 GALLONS U � C v <br /> W 10,00 ,000 Gallon S .5 °' �r <br /> z ?o ,000 Gallon Tank Fitting Orientation f; Split Tank Fitting Orienta tails - o to 0 <br /> MNOT TO SCALENOT TO SCALE <br /> OOU <br /> z :5 low <br /> r <br /> � oOf Material List at Tank SEE NOTE BELOW Material Llst at Dib enser Island SEE NOTE BELOW CL <br /> N a p General Notes04 <br /> ITEM DESCRIPTION )ITEM DESCRIPTION O C O <br /> "XERXES" FIBERGLASS UNDERGROUND GASOLINE STORAGE TANK MULTI-PRODUCT DISPENSERS "GIWARCO" ADVANTAGE SERIES 879 (THREE PRODUCT MPD W/ SINGLE HOSE PER SIDE) 1. THE UNDERGROUND TANK SHALL BE A UNDERWRITER LABORATORIES INCORPORATED W �- <br /> 12,000 GAL. 7 W BALANCE VAPOR RECOVEI"ZY <br /> Oj (EXISTING TO REMAIN) 26 / CHLUMBERGER" 4331-2A (THREE PRODUCT MPD W/ SINGLE HOSE PER SIDE) TANK LISTED FOR THE UNDERGROUND STORAGE OF ALL FLAMMABLE AND COMBUSTIBLE <br /> xr' „11 <br /> OKHEIM H422-8R3 (THREE PRODUCT MPD W/ SINGLE HOSE PER SIDE) MOTOR FUELS. LISTING MUST INCLUDE THE ABILITY TO WITHSTAND A VACUUM TEST L+ <br /> 48" TURBINE & 42" FILL Y a :e'd ` - OF 13.8 INCHES OF HG. (v . Q <br /> 2 SIDE CONTAINMENT SUMPS "XERXES" (TURBINE SIDE SUMP TO BE CLAMP DOWN WATERTIGHT VERSION) y: 27 COAXIAL DISPENSER <br /> ER N8ZZLE EMCO WHEATON 4005 #EW-N4005UF <br /> O ( ENTURI SME 2. UNDERGROUND TANK INSTALLATION ANO TESTING SHALL BE PER U. L. LISTED v <br /> (SEE DLTS. #t & #2 DWG. TK3-1) MANUFACTURER'S INSTALLATION INSTRUCTIONS". INSTALLATION SHALL CONFORM TO <br /> NFPA-30 AND ALL APPLICABLE LOCAL AND STATE REGULATIONS. <br /> "XERXES" O COAXIAL FUEL HOSE (VENTURI STYLE) Ca <br /> O <br /> 3 COLLAR AT SUMP 28 6'- 0" LONG 6' 0 GOODYEAR, STANDARD MODEL # GY-MX48 3. MONITOR SYSTEMS FOR THE INTERSTICE SHALL BE: BY A VEEDER ROOT LIQUID SENSOR, rt+ C <br /> AND IN ACCORDANCE WITH APPLICABLE LOCAL AND STATE REGULATIONS. G <br /> O42" DIA. MANHOLE "FIBERLITE" #FL-42 (WITH BLACK COVER - NO SUBSTITUTES) 294. BEDDING AND BACK FILL MAY BE SAND, PEA GRAVEL, ROUNDED AGGREGATE CRUSHED LLQ ,.. cd <br /> RAIN TIGHT FUEL HOSE BREAKAWAY VALVE "HUSKY #HS-3360VR STONE OR NATIVE SOIL IN ACCORDANCE WITH MANUFACTURER'S CURRENT INSTALLATION ^^ <br /> INSTRUCTIONS AND ARCO SPECIFICATION 13800. hF. <br /> O <br /> EXTRACTOR, FITTING "DPW" OPW-233VM-4422 " 5. THE DESIGN, ASSEMBLY, AND TESTING OF THE PIPING SYSTEM SHALL BE IN CONFORMANCE cd <br /> 4"X4"%2"X2" <br /> 5 9 :.>�► <br /> OSE RETRACTOR-90'X RED JACKET MODEL # RJ-884-034-5 WITH THE APPLICABLE SECTION OF ANSI-837, AMERICANNATIONAL STANDARD CODE <br /> FOR PRESSURE PIPING, AND NFPA 30, FLAMMABLE AND COMBUSTIBLE UQUIDS CODE. <br /> �r <br /> OC RAIN COLLAR CAP W/BAND "XERXES" COAXIAL HOSE CLAMP GOODYERA MODEL #GY-CHC 6. ALL ASSOCIATED PIPING SHALL BE PROTECTED FROM CORROSION. <br /> SEALING CLAMP 7. SEE DRAWINGS FOR NUMBER OF FITTINGS, CONFIGURATION, ACCESSORIES AND SUMP <br /> RISER DETAILS, <br /> (D BALL FLOAT VALVE "DPW" OPW-53VML-0120 9C STANDARD FUEL HOSE WHIP GOODYEAR MODEL # GY-MX48 4^)` <br /> List <br /> p p W <br /> 8� TURBINE PUMP 1.5 -H P. STANDARD "F.E. PETRO" MODEL # STP-V-150, 'RED JACKET" MODEL # P150S1 OR # AGP15051 Abbreviations List Material List at Dispenser Containment Basin SEE NOTE BELOW . (c <br /> SA TURBINE PUMP 2 H.P. VARIABLE W/ "FE. PETRO" MODEL # IST-3 (INSTALLED ONLY ON UNLEADED 87 OCTANE TANK) ITEM DESCRIPTION <br /> O 3 PHASE POWER (SIPHON CHECK VALVE NOT ORDERED IN THIS CONFIGURATION) <br /> ABBR. DESCRIPTION ABBR. DESCRIPTION <br /> PRODUCT IMPACT VALVE 0 ,C. <br /> 30 AASPHALT CONCRETE MNPT MALE NATIONAL PIPE THREADS DOUBLE POPPET "DPW" #10-BHCP-5830 (PRE-INSTALLED IN CONTAINMENT BOX) <br /> OLEAK (MECHANICAL) V/ <br /> 'VAPORLESS" MODEL #LDS-2000 API AMERICAN PETROLEUM INSTITUTE N.C. NORMALLY CLOSED + ' <br /> DETECTOR VAPOR RECOVERYAPPROX. APPROXIMATE NIP NIPPLE O <br /> 31 "DPW" #60VSPC-1001 (PRE-INSTALLED IN CONTAINMENT BOX) QJ �„ Z <br /> IMPACT VALVE (TOP ENTRY) AUX. AUXILIARY NPT NATIONAL PIPE THREAD <br /> 10 x 24" L FLEX CONNECTOR 'TfTEFLEX" U.L. LISTED #110765-32-0240 (n Q c <br /> W <br /> 0/SWIVEL END BLU. BLUE NO. NUMBER <br /> 1-12' FLEX CONNECTOR 24" G• <br /> 32 MALExMALE W/ SWIVEL END TITEFLEX U.L LISTED #110165-24-0240 (PRE-INSTALLED IN CONTAINMENT BOX) BLK. BLACK N.O. NORMALLY OPEN •QS <br /> STAINLESS STEEL THROUGHT OUT C. CONDUIT N/A NOT APPLICABLE c7� Ate` C <br /> 11 3"K2" TEST REDUCER "ENVIRON" EP-RTR-3020 W/ TEST VALVE COMB. COMBINATION N <br /> "T.S. NOT TO SCALE <br /> 34 UNDER DISPENSER SPILL "AMERICAN CONTAINMENT" MODEL AC-ARCO-GILBARCO, AC-ARCO-TOKHEIM OR AC-ARCO-SCHLUMBERGER (f, <br /> 18" DIA INSPECTION CONTAINMENT SUMP CONN. CONNECTOR/CONNECTION O.D. OUTSIDE DIAMETER „D V <br /> 12 <br /> WELL MANHOLE (WATERTIGHT) "POMECO" P-110-18WT CORP. CORPORATION P PRODUCT UNE <br /> UNDER DISPENSER SUMPCENTER LINE PVC POLYVINYL CHLORIDE ~ J c:INSPECTION WELL PIPE - 4" c - <br /> 35 'VEEDERROOT MODEL #794380-208 (CONTRACTOR TO INSTALL THIS EQUIPMENT) Z a <br /> MONITORING PROBE Q o. <br /> 13 SCHEDULE 40 14' LONG "UNIVERSAL" #650-4013 (EXISTING TO REMAIN) _ DBL. DOUBLE QTY. QUANTITY O / o . <br /> .020" SLITS FACTORY CUT UNDER DISPENSER SUMP D DEEP REF. REFERENCE � c :F v <br /> FILL AND VAPOR RECOVERY, 36 PRODUCT PIPING PENETRATION 'ENVIROW MODEL #FEB-6300 <br /> 14 5 GALLON SPILL CONTAINMENT OPW 1-2100. SERIES, 5-GALLON SPILL CONTAINMENT FITTING 3" DIM. DIMENSION REO'D. REQUIRED (� W Z C <br /> 03 <br /> D.C. DIRECT CURRENT RSG RIGID STEEL GALVANIZED }}��� O � o <br /> k BUCKETS UNDER DISPENSER SUMP DWG. DRAWING SPECS. SPECIFICATIONS VJLL' ,cd c <br /> 37 VAPOR PIPING PENETRATION ENVIRON MODEL #FEB-6200 (CONTRACTOR TO MAKE REQUIRED PENETRATION) <br /> > 15 FILL ADAPTER & CAP "OPW" #634TT-7085 W/ #633-T-8075 (EXISTING) FITTING 2" EMT ELECTRICAL METALLIC TUBING SCH. SCHEDULE ,� U C <br /> r UNDER DISPENSER SUMP ELL ELBOW SCR'D. SCREWED O .� o <br /> 1 16 "DPW" 1611-AV-1620 W 1711T-7085 (EXISTING)1. 38 CONDUIT PENETRATION ENVIRON",MODEL #FEB-3075 , (CONTRACTOR TO MAKE REQUIRED PENETRATIONS) FT. FOOT SEC SECTION ^ � ®O <br /> VAPOR CHECK VALVE # / ) FITTING 3 4" FLEXIBLE TYP. TYPICAL LL• <br /> FLEX. <br /> y & CAP O FULL RADIUS ISLAND FORMSAMERICAN CONTAINMENT" FRP FIBERGLASS REINFORCED PLASTIC U.L. UNDERWRITERS LABORATORY <br /> 39 7•-0" LONG & 4'-0" WIDE <br /> 77 OVERFILL PREVENTION "EMCO WHEATON" #A1100-057 (EXISTING TO REMAIN) I FNPT FEMALE NATIONAL PIPE THREAD U/G UNDERGROUND <br /> < < DROP TUBE i' F.G. FIBERGLASS V VAPOR LINE <br /> m 78 LIQUID LEAK SENSOR 'VEEDER-ROOT" #794380-208 a < ° <br /> _ Ma#e'rial List at Building SEE NOTE BELOW GAL. GALLON VAC VOLT AMP CURRENT � a <br /> AT SUMP <br /> mo ITEM DESCRIPTION GALV. GALVANIZED V.R. VAPOR RECOVERY <br /> r HEX HEXAGON VIO. VIOLET z <br /> a' 1 19 LIQUID LEAK SENSOR 'VEEDER-ROOT" #794390-409 H.P. HORSEPOWER WHT. .� rI5T�7]1�,' fjOl N Z N < 4 <br /> FOR TANK ANNULAR SPACE 40 VENT CAP "DPW' MODEL #DPW-523LP-2203 / �LVJITH POV�7I�IIJI Q <br /> I.D. INSIDE DIAMETER W 41 <br /> o J-BOX JUNCTION BOX NOV 0 9 1999 N <br /> SECONDARY I I <br /> 20 CONTAINMENT PIPING A.O. SMITH REDTHREAD (BY G.C.) L LONG v 'n ' <br /> c O "VEEDER-ROOT" TLS-350 W/O PRINTERPRINTER ONLY INSTALLED WITH TANK GAUGING WHICH .� "t <br /> 41 LEAK DETECTION MONITOR CONSOLE IS TO BE A SITE SPECIFIC OPTION) (SEE DWG. TK4-1) MAX. MAXIMUM ENVIRONMENTAL HEALTH in 0 <br /> - - ' PERMITISERVICES <br /> t PRIMARY MANE. MANUFACTURER NOTE: THIS MATERIALS EQUIPMENT SCHEDULE IS NOT A <br /> a 21 A.O. SMITH REDTHREAD (BY G.C.) GILBARCO UNIVERSAL DISPENSER DISTRIBUTION BOX AND PAM UNIT <br /> o CONTAINMENT PIPING 42 INTERFACE BOX SCHLUMBERGER X-PIC AND JUNCTION BOX MIN. MINIMUM COMPLETE LIST OF MATERIALS. CONTRACTOR IS <br /> TOKHEIMMODEL 67 67A RESPONSIBLE FOR ALL MISCELLANEOUS EQUIPMENT, <br /> X / (SEE DWG. TK4-1) MATERIALS AND DEVICES TO PROVIDE A COMPLETE master release date <br /> m 1 <br /> Q BULKHEAD FTTTING "ENVIRON" 3" FEB-6300 2" FEB-6200 <br /> ' x EMERGENCY CUTOFF SWITCH SQUARE D CLASS 39001 K25 FLUSH PLATE PUSH-BUTTON W/ K60 COVER.- INDOOR AND OPERABLE SYSTEM. <br /> o 22 �� <br /> 43 (INDOOR) (SEE DWG. TK4-1) g, N0. ARCO PRODUCTS COMPANY MASTER REVISIONS <br /> OCOMPRESSION FITTING, "ENVIRON" 3/4" #FEB-3075, 1' #FEB-3100 DATE REVISIONS PROJECT RELEASE prof axe. drawn by <br /> AIRTIGHT (AT SUMPS) 44 EMERGENCY CUTOFF SWITCH SQUARE D CLASS 9001 KR3RH6 PUSH-BUTTON N.C. WITH K60 COVER IN WEATHERPROOF 1 11/9/99 PER SAN JOAQUIN COUNTY EHS O.C. <br /> O (OUTDOOR) ENCLOSURE (SEE DWG. TK4-1) PERMIT ro'ect facilit <br /> _D 24 -2" BALL VALVE 150 WSP/600 "JOMAR" SYSTEM-4 #T-100-708 - p�- F y <br /> r FORGED BRASS FULL PORI - BID 5450 <br /> "XERXES" #0224-8 (INSTALLED ON THE FILL SIDI OF THE 20,000 GALLON TANK AND ON THE - ------ -- - <br /> O TANK TURBINE MANWAY ' CONST. sheet / file/ <br /> H 28 ,Ig@Ip{Eny) q"T1�i�QI�'�p` .LpN,•TANK WHf3 SITE CONFIGURATION HAS GREATER THgN TKT�� <br /> ''FC'�FL7Cl M�..R06 QfJTi�CLJ'�`9F"+F AS-BUILT <br /> of <br />