My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2185
>
2300 - Underground Storage Tank Program
>
PR0231118
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 11:50:39 AM
Creation date
11/5/2018 10:00:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231118
PE
2371
FACILITY_ID
FA0003284
FACILITY_NAME
FOOD MART GASOLINE*
STREET_NUMBER
2185
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14113045
CURRENT_STATUS
01
SITE_LOCATION
2185 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FREMONT\2185\PR0231118\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/10/2017 7:56:09 PM
QuestysRecordID
3724126
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iUNIFIED PROGRAM CONSOLIDATED FORM <br /> i <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> NI.PIPING CONSTRUCTION(Check a0 that apply) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE '-i 1 PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2. SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ❑ 1. SINGLE WALL ❑ 3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER J*1 2 DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL ❑99. OTHER <br /> MANUFACTURER MANUFACTURER <br /> r �l� MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 8. FRP COMPATIBLE W/100%METHANOL ❑ 1. BARE STEEL ❑ 8. FRP COMPATIBLE W/1D0%METHANOL <br /> MATERIALS AND ❑ 2 STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS 1195 UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ B. FLEXIBLE(HDPE) ❑99. OTHER <br /> © 4. FIBERGLASS ❑ 8. FLEXIBLE(HDPE) ❑99. OTHER ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION <br /> ❑ 5. STEEL W/COATING ❑ 9. CATHODIC PROTECTION ❑ 5. STEEL W/COATING ❑95. UNKNOWN <br /> VII.PIPING LEAK DETECTION(Check aft that appy) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check all that appy): PRESSURIZED PIPING(Check all that appy): <br /> 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE.AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS ❑ 2 MONTHLY 0 2 GPH TEST <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPM) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that appy): <br /> ❑ 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 8. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING _ <br /> PRESSURIZED PIPING(Check all that apply) PRESSURIZED PIPING(Check all that appy) <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND <br /> (Check one) 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> © b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION ❑ D AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPM TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION <br /> El11 AUTOMATIC LEAK DETECTOR <br /> ❑ 12. ANNUAL INTEGRITY TEST(0 1 GPH) ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM. <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check ell that apply) EMERGENCY GENERATORS ONLY(Check as that applA - <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 18. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 18. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5. TRENCH LINER/MONITORING <br /> 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 8. NONE <br /> IX,OWNER/OPERATOR SIGNATURE <br /> I certify that the information provlded herein is true and accurate to the best of my knowledge. <br /> SIGNATURE OF OWNER/OPERATOR DATE <br /> NAME OF OWNER/OPERATOR font) TITLE OF OWMERrOPERATOR <br /> Permit Number(For local use only) Permit Approved(For local use only) Permit Expiration Date(For local use only) <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.