My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:21:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> GEMCO RIPON TRUCK PLAZA INC (209) 599-5900 March 06, 2017 <br /> Facility Address; CERS ID: <br /> 1022 E FRONTAGE RD, RIPON, CA 95366 10180637 <br /> Inspection Contact: Title: Phone: <br /> Kulwinber Johal CEO (209) 541-8190 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION -Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent Given% <br /> Inspection O Photos 0Sam les Kulwinber Johal, CEO <br /> Service Technician Onsite Exp.Date: Designated Operator: Exp.Date: <br /> Zane Nimmo 06/19/2017 Greg Kaiser 10/17/2017 <br /> Service Technician Manufacturer's Training <br /> VMI, 01/08/19; VR, 07/2518; Tank Tester,03/31/19 <br /> = a ornia Codeo egu ations HSC=heallin and 6atety Gode CFR=Codeo a eral Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate o V o R r COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V o R ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ■V u R ❑COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ■V ❑R ❑COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan ■V ❑R ❑COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan n V ❑R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ■R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment n V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ■V m R ❑COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V o R n COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ■V ❑R n COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V u R u COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days ❑V ❑R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R u COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V to R ❑COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V u R in COS <br /> 119 HSC 25299 Documents were falsified or misrepresented o V ❑R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V in R ❑COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ■V ■R ❑COS <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored n V in R ❑COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions e V m R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑V ❑R ❑COS <br /> FA0000650 PR02316D4 SC001 03/06/2017 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 7 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.