My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 3:22:51 PM
Creation date
11/5/2018 10:21:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\COMPLIANCE INFO.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> The following is an itemized list of underground storage tank violations that have not <br /> been addressed for GEMCO RIPON TRUCK PLAZA INC as of March 02, 2017. <br /> Open violations from March 17, 2016 inspection <br /> Violation#107 -Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> An accurate UST Monitoring Site Plan was not submitted, the submitted plan doesn't identify the sensor/monitoring <br /> locations. A site plan must be submitted identifying the locations where monitoring will be performed. Immediately <br /> log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.govi and upload a copy of <br /> the UST Monitoring Site Plan. <br /> Xonnta <br /> Failed to submit secondary containment test report within 30 days. <br /> nmenttesting was scheduled to be performed on 5-27-2015 and a test report has not been <br /> HD. A copy of the test report must be submitted within 30 days of the test. Immediately submit a <br /> port to the EHD or schedule this test and provide 48 hours notification to the EHD. <br /> Violation#201 -Failed to maintain alarm logs and/or records of follow up actions. <br /> Monitoring records (monitoring system certification and the secondary containment test reports)for the 2015 were <br /> not found on site. These records shall be maintained on site for at least three years. Monitoring records include: (1) <br /> date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) <br /> results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br /> readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br /> inventory readings and reconciliations. Immediately locate and maintain all maintenance and monitoring records for <br /> the last three years on site and submit copies to the EHD. Submit proof of correction to the EHD. <br /> Violation#321 -Overfill prevention was overridden. <br /> The mechanical overfill prevention device on the 87 UST was overridden by the presence of a plastic(flexible) hose <br /> placed in the drop tube. The hose, which measured approximately 135 inches, was removed by the service <br /> technician on site. Mr. Harprit Johal indicated that he didn't know about the hose being present inside the drop tube, <br /> and stated that the previous operator was probably stealing gas via this hose. Mr. Johal also stated that about a <br /> month ago they were checking the fuel level for the air quality testing (with a measuring stick)and he did notice that <br /> the stick"would not go all the way through", he also stated that at that time he was not sure why it was happening <br /> nor did he realize that there is anything unusual about it. His stated that he was planing on asking the service <br /> technician about it today. Take all necessary precautions to prevent this in the future <br /> LDCD <br /> OVA <br /> -�,-P . w <br /> � 32 � � Do� o✓� �l.e � \ag�z InDu �� � r�.`.0 . <br /> Page 1 of 1 <br />