My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2300 - Underground Storage Tank Program
>
PR0231604
>
COMPLIANCE INFO_1998 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 3:20:17 PM
Creation date
11/5/2018 10:22:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998 - 2004
RECORD_ID
PR0231604
PE
2361
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0231604\COMPLIANCE INFO 1998 - 2004.PDF
QuestysFileName
COMPLIANCE INFO 1998 - 2004
QuestysRecordDate
11/29/2017 11:11:14 PM
QuestysRecordID
3738035
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i4 y <br /> n t;L <br /> CCP,TITLE 23.DIVISION 3 CHAPTER 16 DERGROUND STORAGE TANK REGULATIONS <br /> (3) Other monitoring methods may be used in lieu of the requirement in <br /> subdivision(2) if it is demonstrated to the satisfaction of the Focal agency <br /> that the alternate method is as effective as the methods otherwise required <br /> by this section. A continuous monitoring system as described in <br /> subdivision(1), which shuts down the pump in addition to activating,the <br /> alarm system, satisfies the automatic line leak detector requirement of <br /> subdivision <br /> (4) Monitoring shall be conducted on all underground pressurized piping with <br /> secondary containment at least annually at a pressure designated by the <br /> } equipment manufacturer, provided that the method is capable of detecting a <br /> minimum release equivalent to 0.1 gallon per hour defined at 150 percent <br /> ✓✓✓ of the normal operating pressure of the product piping system at the test <br /> pressure with at least a 95 percent probability of detection and not more <br /> than a 5 percent probability of false alarm. This re uirement is waived if <br /> the criteria in subsection (g) of this section are met. <br /> (g) Underground pressurized piping which meets all of the following requirements <br /> satisfies the annual tightness test requirement specified in subsection (f)(4): <br /> (1) The secondary containment system is equipped with a continuous <br /> monitoring system. The leak detection device may be located at the pump <br /> sump if the piping slopes back to this paint. <br /> (2) A continuous monitoring system is connected to an audible and visual <br /> alarm system and the pumping system. <br /> (3) A continuous monitor shuts down the pump and activates the alarm system <br /> when a release is detected. <br /> (4) The pumping system shuts down automatically if the continuous <br /> monitoring system fails or is disconnected. <br /> (5) The requirements of subdivisions (3) and-(4) do not apply to an emergency <br /> generator, provided the monitoring system is checked at least daily. <br /> Authority: Health and Safety Code 25299.3 and 25299.7 <br /> Reference: Health and Safety Code 25281, 25291, 25299; <br /> 40 CFR 280.20, 80.40-280,45 <br /> 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.