Laserfiche WebLink
1 <br /> CrISIDONC. SACRAMENTO <br /> r <br /> available, the potential of incurring liability from environmental <br /> impairment and the threat to ground water would be least if the <br /> following recommendations are implemented. <br /> • 89-2-1: All contaminated soil containing more than 100 ppm TPH <br /> should be excavated, treated, and disposed of. Adequate <br /> shoring of the excavation should be maintained to ensure <br /> the integrity of the surrounding structure and the <br /> sidewalls of the hole. A higher cleanup level will be <br /> employed should a threat to the facility or transmission <br /> y cable exist. I <br /> * 89-2-2: The remediation activities should be conducted as soon <br /> after regulatory agency approval has been granted as is <br /> feasible. <br /> 7.0 APPENDIX <br /> Appendix A comprises the Appendix to this report. The contents of <br /> the Appendix are listed below. <br /> Appendix A. Site Assessment of the Pacific Bell Ashley Road <br /> Stockton Facility (UE-132) , 7644 Ashley Road, Stockton, <br /> California <br /> k <br /> 19 <br />