My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
816
>
2300 - Underground Storage Tank Program
>
PR0231470
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 2:09:29 PM
Creation date
11/5/2018 10:33:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231470
PE
2361
FACILITY_ID
FA0003911
FACILITY_NAME
VAN DE POL ENTERPRISES INC
STREET_NUMBER
816
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102010
CURRENT_STATUS
01
SITE_LOCATION
816 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\816\PR0231470\COMPLIANCE INFO\2016 - PRESENT.PDF
QuestysFileName
2016 - PRESENT
QuestysRecordDate
9/22/2016 7:01:58 PM
QuestysRecordID
3006673
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> VAN DE POL ENTERPRISES INC (209) 466-5921 January 25, 2016 <br /> Facility Address: CERS ID: <br /> 816 E FRONTAGF RD, RIPON, CA 95366 10181513 <br /> Inspection Contact: Title: Phone: <br /> Ted Shackelford Operator (209) 649-8308 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> A Inspection 7, Photos Z Sam les Ted Shackelford. Operator <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Felix Ramirez 11/26/2016 David Winkler 03/10/2016- <br /> Service <br /> 3/10/2016Service Technician Manufacturer's Training <br /> Tank Tester,05/31/17; Veeder Root, 07/07/16. VMI Tester,11/06/17 <br /> CCR California ode of Regulations HSC=Health and Safety Code CFR=Code of FederalRegulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ❑V o R ❑COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system o V o R o COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted o V ❑R ❑COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current ■V ■R o COS <br /> 105 HSC 25286(c) Current BOE number not submitted ❑V o R o COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ■V o R ❑COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑V o R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing ❑V ❑R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment o V o R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ❑V o R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V o R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V o R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V o R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V o R ❑COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days ❑V o R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V ❑R ❑COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well o V c R ❑COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test o V ❑R ❑COS <br /> 119 CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V o R ii COS <br /> 120 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R ❑COS <br /> 121 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V ❑R o COS <br /> 122 HSC 25299 Documents were falsified or misrepresented o V o R ❑COS <br /> 123 CCR 2661 Permit to repair UST system not obtained ❑V ❑R ❑COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R ❑COS <br /> 125 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V o R o COS <br /> Received by Inspector: ro Phone: Date: <br /> (initial): STACY RIVERA, Senior REHS (209) 468-3440 01/25/2016 <br /> Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.