My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
4 (STATE ROUTE 4)
>
25343
>
2300 - Underground Storage Tank Program
>
PR0234397
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:08:14 AM
Creation date
11/5/2018 10:35:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0234397
PE
2381
FACILITY_ID
FA0003708
FACILITY_NAME
FARMINGTON FIRE DISTRICT
STREET_NUMBER
25343
Direction
E
STREET_NAME
STATE ROUTE 4
City
FARMINGTON
Zip
95230
APN
18713008
CURRENT_STATUS
02
SITE_LOCATION
25343 E HWY 4
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\F\HWY 4\25343\PR0234397\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
4/15/2013 8:00:00 AM
QuestysRecordID
150259
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM m <br /> EDBAOR <br /> ;FACILITY <br /> ❑ 1 NEW PERMIT 3 RENEWAL PERMIT �-.�/ <br /> ❑ 2 INTERIM PERMIT ❑ 6 AMENDED PERMIT LJ 5 CHANGE OF INFORMATION a 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 8 TEMPORARY TANK CLOSURE ❑ B TANK REMOVED Q <br /> NAME WHERE TANK IS INSTALLED: Z�J z'" <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN If <br /> A OWNER'S TANK I.O.i <br /> gZQ; <br /> C. DATE INSTALLED(MOVDAYiY'EAfl) EEEH <br /> II.TANK ONTENTS IFA-11SMARKED,COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE FUEL ❑ d OIL S. C. ❑ ipURE <br /> NLEADED REGULAR 3 DIESEL ❑ 9 AVMTIONGAS <br /> ❑ 2 PETROLEUM ❑ SO EMPTY ay PRODUCT ❑ 1E PREMIUM d GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ DS UNKNOWN ❑ 2 WASTE UNLEADED 5 JET FUEL <br /> ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.is <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALLTHAT APPLIES IN BOX <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ d SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 6 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ S POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ S 100% METHANOL COMPATIBLE W/FRP <br /> (PdmwyTmk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 05 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR <br /> ❑ 5 GLASS LINING ❑ 9 UNLINED ❑ 95 UNKNOWN Q 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ s FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U d FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 9 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODICPROTECTKNN A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 MONRORI ALL ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> �JFff�sl <br /> L CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 7 VAPOR MONITORING❑ d AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> -( TANK TESTING ❑ 7 INTERSTITIALMONITORWG ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS INERTMATERIAL? YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANTS NAME pp7E <br /> IvaxrED s slc.AT. <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILTTY# TANK# <br /> STATE I.D.# ® I I I I I 110[j] fARAYYzs' <br /> PERMIT NUMBER PEflMR APP BQ DBV/DATE 26 PERMIT EXPIRATION DATE <br /> FORMS (9-9q THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPUCATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORCV1 M 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.