Laserfiche WebLink
do `11.. A a BCE#10199 Tank <br />UNIFIED PROGRAM CONSOLIDATED FORM�� I <br />UNDERGROUNDSTORAGETANK It t7 ' <br />OPERATING PERMIT APPLICATION - TANK INFORMATION (One fo m e uST) <br />TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections I, II, III, IV, and IX below) 430 <br />❑ 1. NEW PERMIT ❑ 3. RENEWAL PERMIT ® 5. CHANGE OF INFORMATION <br />❑ 6. TEMPORARY UST CLOSURE ❑ 7. UST PERMANENT CLOSURE ON SITE ❑ 8. UST REMOVAL <br />DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 4301 <br />I. FACILITY INFORMATION <br />FACILITY ID # (Agency Use Only) <br />1 <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) 3 <br />Costco Gasoline (Loc. No. 38) <br />BUSINESS SITE ADDRESS 103 <br />CITY 106 <br />1616 E. Hammer Lane <br />Stockton <br />I1. TANK DESCRIPTION <br />TANK ID#432 <br />1 <br />TANK MANUFACTURER 633 <br />TANK CONFIGURATION: THIS TANK IS 034 <br />2 <br />Containment Solutions <br />0 1. A STAND-ALONE TANK <br />02. ONE NACOMPARTMENTED UNIT. <br />Complete one pipe, for each com mne.t in the unit. <br />DATE UST SYSTEM INSTALLED 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS IN THE UNIT 437 <br />March 2004 <br />20,000 <br />1 <br />III. TANK USE AND CONTENTS <br />TANKUSE N Ia. MOTOR VEHICLE FUELING ❑ IT. MARINA FUELING ❑ k. AVIATION FUELING 439 <br />❑ 3. CHEMICAL PRODUCT STORAGE ❑ 4. HAZARDOUS WASTE (Includes Used Oil ❑ 5. EMERGENCY GENERATOR FUEL IHSC §25281.5(.)) <br />❑ 6.OTHERGENERATOR FUEL ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): 439. <br />CONTENTS PETROLEUM: 0 Ia. REGULAR UNLEADED ❑ k. MIDGRADE UNLEADED ❑ IN. PREMIUM UNLEADED 440 <br />❑ 3. DIESEL ❑ 5. SET FUEL ❑ 6. AVIATION GAS <br />❑ 8. PETROLEUM BLEND FUEL ❑ 9. OTHER PETROLEUM (Specify): 44W <br />NON -PETROLEUM: ❑ 7. USED OIL ❑ 10. ETHANOL <br />❑ II.OTHER NON -PETROLEUMS .ci(): 440b <br />IV. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL 0 2. DOUBLE WALL ❑ 95. UNKNOWN 443 <br />PRIMARY CONTAINMENT ❑ 1. STEEL N 3. FIBERGLASS ❑ 6. INTERNAL BLADDER 404 <br />❑ 7. STEEL + INTERNAL LINING ❑ 95. UNKNOWN ❑ 99. OTHER (Specify): edea <br />SECONDARY CONTAINMENT ❑ 1. STEEL 0 3. FIBERGLASS ❑ 6. EXTERIOR MEMBRANE LINER ❑ 7. JACKETED 005 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑99.OTHER (S eci ): 445a <br />OVERFILL PREVENTION 1. AUDIBLE&VISUAL ALARMS E 2. BALL FLOAT 113. FILL TUBE SHUT-OFF VALVE 452. <br />❑ 4. TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br />V. PRODUCT / WASTE PIPING CONSTRUCTION <br />PIPING CONSTRUCTION ❑ I. SINGLE -WALLED E11) E -WALLED ❑99. OTHER 460 <br />SYSTEM TYPE E 1. PRESSURE [12. GRAVITY 1_13. CONVENTIONAL SUCTION ❑ 4. SAFE SUCTION I23 CCR §363da)(3)] 458 <br />PRIMARY CONTAINMENT ❑ 1. STEEL ❑ 4. FIBERGLASS E & FLEXIBLE ❑ 10. RIGID PLASTIC 464 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99.OTHER(Specify): 464a <br />SECONDARY CONTAINMENT ❑ L STEEL ❑ 4. FIBERGLASS M 8. FLEXIBLE ❑ 10. RIGID PLASTIC 4646 <br />❑ 90. NONE ❑ 95. UNKNOWN ❑ 99.OTHER(Specify): 0fi4c <br />PIPING/TUFIBNE CONTAINMENT SUMP TYPE ❑ 1. SINGLE WALL ® 2. DOUBLE WALL ❑ 90. NONE died <br />VI. VENT, VAPOR RECOVERY (VR) AND RISER / FILL PIPE PIPING CONSTRUCTION <br />VENT' PRIV ARYCONTANMENT ❑ LSTEEL N 4. FIBERGLASS [110. RIGID PLASTIC [190. NONE [199. OI HER(Spceify) 464e <br />464e1 <br />VENT SECONDARY CONTAINMENT ❑ LSTEEL E 4. FIBERGLASS ❑ lo.RIGIDPLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4Mf <br />46,M <br />VR PRIMARY CONTAINMENT ❑ L STEEL 0 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4648 <br />464 1 <br />VR SECONDARY CONTAINMENT ❑ L STEEL 0 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4641 <br />46411 <br />VENT PIPING TRANSITION SUMP TYPEI. SINGLE WALL ❑ 2. DOUBLE WALL [190. NONE 464'. <br />RISER PRIMARY CONTAINMENT ® L STEEL ❑ 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4641 <br />4641 <br />RISER SECONDARY CONTAINMENT ❑ L STEEL 0 4. FIBERGLASS ❑ 10. RIGID PLASTIC ❑ 90. NONE ❑ 99. OTHER (Specify) 4641, <br />464k1 <br />FILL COMFONENTS INSTALLED 1. SPILL BUCKET 0 3. STRIKER PLATEIROTTOM PROTECTOR 0 4. CONTAINMENT SUMP 45la-c <br />VII. UNDER DISPENSER CONTAINMENT (UDC) <br />CONSTRUCTION TYPE E I. SINGLE WALL ❑ 2. DOUBLE WALL ❑ 3. NO DISPENSERS ❑ 90. NONE. 469a <br />CONSTRUCTION MATERIAL ❑ 1. STEEL ❑ 4. FIBERGLASS 0 10. RIGID PLASTIC ❑ 99. OTHER (Specify) 4696, <br />VIII. CORROSION PROTECTION <br />STEEL COMPONENT PROTECTION ❑ 2. SACRIFICIAL ANODE(S) ❑ 4. IMPRESSED CURRENT e 6. ISOLATION 40%' <br />IX. APPLICANT SIGNATURE <br />CERTIFICATION: I certify that this US mpfitible with the hazardous substance stored and that the information provided herein is true, accurate, <br />and in full com ce 'th le reg4iirements. <br />APPLICANT SIGNATURE <br />alo. . <br />DATE <br />November 20, 2012 <br />4]I. <br />APPLICANT NAME (print) <br />APPLICANT TITLE 472. <br />Jeff a <br />Gasoline V.P. <br />UPCF US'f-B -1/2 <br />Rev. (1212007) <br />w <br />