Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:11:03 PM
Creation date
11/5/2018 11:18:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\BILLING 2011-2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED FO� <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1(� <br /> (Two pages per tank) <br /> Page_3 of 6 <br /> TYPE OFACTION D 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION <br /> (Clock ore item only) ❑ 6.TEMPoRARY TANK CLOSURE 430. <br /> ❑ 3.RENEWAL PERMIT <br /> ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8,TANK REMOVED <br /> BUSINESS NAME(same as FACILITY NAME or DBA-Doing Business As) 3. FACILITY <br /> COSTCO GASOLING LOC.NO. 38 <br /> LOCATION WrMIN SITE(Ovtiona0 <br /> 431. <br /> I.TANK DESCRIPTION <br /> (A scaled plot tart with the location of the UST system includingbuildings and landmarks shall be submitted to the local a enc .) <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK Yes No 434. <br /> 2 CONTAINMENT SOLUTIONS If"Yes."compete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS <br /> (YEAR/MO) 437. <br /> 'ff2tt=q) 20,000 1 <br /> ADDITIONAL DESCRIPTION(For Ioca1 use only) <br /> 438. <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE <br /> ® 1. MOTOR VEHICLE FUEL ® la. REGULAR UNLEADED <br /> (IFchecked,complete Petore ❑2. LEADED ❑5. JET FUELum Type) 016 PREMIUM UNLEADED ❑3. DIESEL <br /> 06. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM <br /> ❑Ic. MNGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (form Hazardous Materials Inrontory,page) "I. CAS#(from Hazardous Materials Invents 442. <br /> ❑ 4. HAZARDOUSWASTE Inventory,Page) <br /> (Inemdes Used On) 87 OCTANE 8006-61-9 <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OFTANK ❑L SINGLE WAIL ❑3. SINGLE WALL WITH EXTERIOR <br /> (Check one item only) ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> MEMBRANE LINER 095. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑L HARE STEEL ®3. PIBERGLASS/PLASTIC ❑5. CONCRETE <br /> ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE <br /> REINFORCED PLASTIC(FRP) W/100%METHANOL <br /> ❑99.OTHER: <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC 08. FRP COMPTIBLE W/100%METHANOL <br /> ❑95.UNKNOWN d45. <br /> (Check one item only) ❑2. STAINLESS STEEL[14. STEEL CLAD W/FIBERGLASS 119. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑l0. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR UNING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ,p�KN OWN 446. DATE INSTALLED 447. <br /> (Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ®3.FIBERGLASS REINFORCED PLASTIC [195.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION [14.IMPRESSED CURRENT ❑99.OTHER <br /> (If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEARINSTALLED 450. TYPE 451. OVERFILL PROTECTIO <br /> (Check all that apply) ®1.SPILL CONTAINMENT N®1 ALARM EQUIPMENT: YEAR INSTALLED 452. <br /> ®2.DROP TUBE _ [13.FILL TUBE SHUT OFF VALVE <br /> ®3.STRIKER PLATE ®2.BALL FLOAT_ [14.EXEMPT <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453 <br /> (Check all that apply) IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check one item only) <br /> ❑LVISUAL(EXPoSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> [12.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION 1:18.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING 1199. OTHER <br /> V.TANK CLOSURE INFORMATION It PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPI hwfwrc-b(I/99)-114 http://www.unidocs.org <br /> Rev.02/16ft <br /> t <br />