Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This forth must be used to document testing and servicing of monitoring equipment. A separate certification or report must be Prepared for each <br /> monitoring system control Panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Shell 1-5 Bldg.No.: <br /> Site Address: 717 W. Eighth St. City: Stockton Zip: 95206 <br /> Facility Contact Person: Owner Contact Phone No.: (209) 939-0961 <br /> Make/Model of Monitoring System: Veederoot TLS350 Date of Testing/Servicing: 3/5/2014 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID:_#1-Regular Tank ID: #2-Premium <br /> ®In-Tank Gauging Probe. Model: 847390.109 M In-Tank Gauging Probe. Model: 847390-109 <br /> M Annular Space or Vault Sensor. Model: 794390-302 M Annular Space or Vault Sensor. Model: 794390-302 w Split tank <br /> M Piping Sump/Trench Sensor(s). Model: 794380-208 M Piping Sump/Trench Sensor(s). Model: 794380.208 <br /> M Fill Sump Sensor(s). Model: 794380-208 M Fill Sump Sensor(s). Model: 794380-208 <br /> ®Mechanical Line Leak Detector. Model: Veederoot FX1 V M Mechanical Line Leak Detector. Model: VMI LD2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> M Tank Overfill/High-Level Sensor. Madel: ATG 1 M Tank Overfill/High-Level Sensor. Model: ATG <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: #3-Diesel Tank ID: <br /> M In-Tank Gauging Probe. Model: 847390.109 ❑In-Tank Gauging Probe. Model: <br /> M Annular Space or Vault Sensor. Model: Split tank w/Prem ❑Annular Space or Vault Sensor. Model: <br /> M Piping Sump/Trench Seasons). Model: 794380-208 ❑Piping Sump/Trench Seasons). Model: <br /> ®Fill Sump Sensor(s). Model: 794384208 ❑Fill Sump Sensor(s). Model: <br /> M Mechanical Line Leak Detector. Model: Veederoot FX1 DV ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> M Tank Overfill/High-Level Sensor. Model: ATG ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> M Dispenser Containment Sensor(s). Model: 794380-208 M Dispenser Containment Seasonal. Model: 794384208 <br /> M Shear Valve(s). M Shear Valve(s). <br /> ❑Dispenser Containment Hoat(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> M Dispenser Containment Sensor(s). Model: 794380-208 M Dispenser Containment Sensor(s). Model: 794380-208 <br /> M Shear Valve(s). M Shear Valve(s). <br /> ❑Dispenser Containment Hcaus)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11-12 <br /> M Dispenser Containment Sensor(s). Model: 794380.208 M Dispenser Containment Sensor(s). Model: 794380-208 <br /> M Shear Valve(s). M Shear Valve(s). <br /> ❑Dispenser Containment Floats)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ❑ System set-up ®Alarm history report <br /> Technician Name(print): Jeff Conger Signature: ---�- l a---- <br /> Certification No.: A22219 License.No.: ICC#1801782 UT CSLB#894932 <br /> Testing Company Name: Pinnacle Fuel Compliance Services Inc. Phone No.: (408) 206-9840 <br /> Testing Company Address: P.O. Box 32849 San Jose, CA 95152-2849 Date of Testing/Servicing: 3/5/2014 <br /> Page 1 of 3 <br />