My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 9:30:46 AM
Creation date
11/5/2018 11:18:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical / Electronic Leak Detector Test <br /> Site: Test Company <br /> Shell 1-5 Pinnacle Fuel Compliance <br /> 717 W. Eighth St. P.O. Box 32849 <br /> San Jose, CA 95152 <br /> Stockton, Ca. 95206 (408)206-9840 <br /> Test Information <br /> 1 2 3 4 <br /> Product #1-Reg #2-Prem #3-Diesel <br /> Manufacturer Veederoot VMI Veederoot <br /> Model FX1V LD2000 FX1DV <br /> Full Operating Pressure (psi) 38 38 38 <br /> Line Bleed Back (ml) 125 140 100 <br /> Trip Time (sec) 3 5 2 <br /> Metering Pressure 12 26 12 <br /> F/E Holding Pressure (psi) 27 37 25 <br /> Test Leak Rate (ml/min)(gph) 189 189 189 <br /> PASS or FAIL I PASS PASS PASS <br /> This form certifies that the annual line leak detector tests were performed at the above referenced <br /> facility according to the equipment manufacturers procedures and limitations and the results as listed <br /> are to my knowledge true and correct.The mechanical/electronic line leak detector test pass/fail is <br /> determined using a low flow rate threshold trip rate of 3 gph at 10psi. <br /> Tester: Jeff Conger Date: 3/5/2014 <br /> Signature: Lic# 1081782 UT rz NACLE <br /> Mechanical/Electronic Leak Detector Test <br />