Laserfiche WebLink
ALGtIVED <br /> Facility Name: Costco # 038 Stockton (Page 2) MAR 16 2016 <br /> D. Results of Testing/Servicing <br /> Comtete the followin checklist: <br /> Software the <br /> Installed: 333.04 <br /> ®Yes Li No Is the audible alarm o erational? <br /> ®Yes ❑ No Is the visual alarm operational? <br /> ®Yes ElNo* Is the print function operational? <br /> ®Yes ElNo* Were all sensors visually inspected, functionally tested, and confirmed o erational? <br /> ®Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other <br /> e ui ment will not interfere with their proper operation? <br /> ®Yes El No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. <br /> ❑ N/A modem) operational? <br /> ®Y ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br /> ❑ N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If <br /> yes: which sensors initiate positive shutdown? (Check all that apply) ® Sump Sensors; <br /> Dispenser Containment Sensors. <br /> Did you confirm positive shutdown due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br /> H-s- <br /> ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device, is <br /> ❑ N/A the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? At <br /> what percent of tank capacity does the alarm tri er? 90% <br /> Yes* ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other <br /> equipment replaced and list the manufacturer name and model for all replacement parts in Section <br /> E, below. <br /> ®Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check a// <br /> that apply)❑ Product; ® Water. If yes, describe causes in Section E, below. <br /> Yes No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if <br /> a I'cable <br /> ®Yes ❑ No* Is all monitoring equipment oerational per manufacturer's specifications? <br /> 7. Comments: There was a small amount of liquid found in the 87b fill sump from condensation build up. <br /> There was also a small amount of brine at the bottom of the additive Fill/STP. Inspected inside of sump and <br /> found no visible leaks. Brine must have been spillage from a technician filling the resevoir. <br /> s> <br />