My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 11:13:49 AM
Creation date
11/5/2018 11:20:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stale Water Resources Contrcoard Page 1 of 2 <br /> Home-M Water Issues,-* Programs-s Ust-S Leak Prevention•-s Lgl13 -s Vendors <br /> UST Programs - LG 113 <br /> ....... ................................................................................................................... <br /> Issue Date: December 22, 2003 <br /> Revision Date: March 6, 2015 <br /> Veeder-Root <br /> TLS-350 Series, TLS-450 Series, EMC, EMC-PC, EMC Enhanced, EMC-PC Enhanced, and Red Jacket <br /> ProMax <br /> with Magnetostrictive Sump Sensor Series 857060-xxx* and 857080-xxx* <br /> INTERSTITIAL DETECTOR (LIQUID-PHASE) <br /> Detector: <br /> Output type: qualitative, discriminating* <br /> Sampling frequency: continuous <br /> Operating principle: magnetostrictive probe with dual floats <br /> Test Results: <br /> *California requires annual certification of all leak detection equipment. The certification of <br /> discriminating sensors should include functional testing of both water and product detection <br /> capabilities. <br /> 24" Sump Sensor <br /> Series 857060- gas on 7" of water diesel on 7" of water <br /> xxx** and 857080- unleaded (fuel alarm in Dresence (fuel alarm in <br /> )Cxx* oasoline diesel*** water of waterl presence of water) <br /> Detection time (sec) —10 —10 —10 —10 —10 <br /> Fall time (sec) —10 —10 —10 —10 —10 <br /> Minimum product 1.368 1.329 1.614 1.116 1.101 <br /> I (in) <br /> xxx** - designates sensors in the 857060 and 857080 series containing: 857060 and 857080-101, <br /> -102, -111, -112, -121, -122, -211, -212, -221, and -222 <br /> ***Evaluations determined these sensors' responses to the liquids shown above. Biodiesel blends 136- <br /> B20 meeting ASTM D7467 and biodiesel B100 meeting ASTM D6751 would also produce an alarm if the <br /> sensor threshold is exceeded. Responses to these fuels were not determined, but would be expected to <br /> be very similar to the diesel responses. <br /> Evaluations determined that the Magnetostrictive Sump Sensor Series 857080-xxx responds <br /> to 100% Lubrizol Ultrazol 9888, 100% Afton OTR 8332G, and 100% Afton OTR 8843G. Alarm <br /> and response can be expected to be very similar to the response values listed above. <br /> Comments: <br /> One sensor length (24") was evaluated. Results are typical for the other sensors in the 857060-xxx and <br /> 857080-xxx series, regardless of length and programmability options. <br /> All sensors are based on the use of a magnetostrictive sensor that is equipped with two floats. The <br /> http://www.waterboards.ca.gov/water issues/programs/ust/leak_lrevention/lgll3/vendors/... 1/10/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.