My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 11:13:49 AM
Creation date
11/5/2018 11:20:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HAMMER\1630\PR0518624\COMPLIANCE INFO 2016-PRESENT .PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Z <br /> WORK , " •� W <br /> 3 AREA <br /> E M�ORADA LN <br /> -._-. - - —...-- --------_-__....---- Z <br /> Eco 00 <br /> Ali\ <br /> ENVIR� MENT0W. e cZSITE . . . .- w Q 0 <br /> E HAMMER W � B ® - _ - ® ® � U CV J <br /> --- wC 0) Q <br /> LLJ <br /> LL <br /> 4 VEEDER ROOT 3 D N W dig- <br /> EXISTING V <br /> ALARM MONITOR I o � W <br /> SYSTEM, MONITORED 24 0 a 16 9 0 !J d o � Q Z Z <br /> HOURS/DAY \ m Q = J <br /> --- _ - NOT TO SCALE NOT TO SCALE O <br /> ~ W � NZ Q <br /> VICINITY MAP LOCATOR MAP w O O <br /> 0 <br /> LJ ~ a 0 <br /> I <br /> • E= <br /> ~ � Z <br /> PIPING LEGEND o c�To <br /> ~ --- - w to <br /> -- ~ <br /> ~ - -- - -- 2" FLEXIBLE DOUBLE WALL PRODUCT PIPING IN 4" GEODUCT ¢ O <br /> EXISTING CONTROLLER <br /> ENCLOSURE - EXISTING z` OR 3" F.G. DOUBLE WALL VAPOR RECOVERY PIPING W V <br /> EXISTING 2 DOUBLE WALL VENT PIPING <br /> I N � S'� <br /> EXISTING OVERFILL ALARM INSTALLATION NOTES a p <br /> EXISTING ESO z6 <br /> ,--EXISTING CANOPY REMOVE (6) SIX EXISTING "ENCORE 300" DISPENSERS AND REPLACE WITH (6) SIX NEW "GILBARCO ENCORE"-700S <br /> I OVERHEAD SERIES SINGLE HOSE PER SIDE, 2+0-PRODUCT DISPENSERS AS SHOWN. DISPENSERS TO BE FITTED WITH NEW HEALY <br /> STAGE II HOSES AND NOZZLES, BREAKAWAY VALVES PER CARB VR-202. GENERAL CONTRACTOR TO PURGE LINES <br /> EXISTING ISLAND THROUGH EACH METER/NOZZLE WITH 50 GALLON PURGE. ANY AIR POCKETS OR START UP PROBLEMS DUE TO <br /> IMPROPER INSTALLATION OR INCORRECT WIRING THAT DESTROYS ELECTRONICS WILL BE BILLED BACK TO THE <br /> CONTRACTOR. AFTER PURGING THE PRODUCT LINES OF AIR, CONTRACTOR IS TO REPLACE THE FACTORY INSTALLED N <br /> GASOLINE FILTERS WITH THE COSTCO SUPPLIED FILTERS. 0 <br /> EXISTING ESO I -� " - - _ - _ - - _ PERFORM REQUIRED REGULATORY TESTING ON NEW DISPENSERS EQUIPMENT/HARDWARE. REQUIRED REGULATORY J 0 <br /> - - --- -- - - - - TESTING TO BE COMPLETED BY COSTCO'S 3RD PARTY TESTER, COORDINATED BY CONTRACTOR." Q W Z <br /> / EXISTING ESOI D <br /> REMOVE DISPENSER SUMP SENSOR & REPLACE WITH MAG SUMP SENSOR. INSTALL ONE (1) VEEDER-ROOT WIRELESS O Z <br /> RF TRANSMITTER AT EACH DISPENSER FOR UDC SENSOR. INSTALL ONE (1) VEEDER-ROOT WIRELESS RF TRANSMITTER m w <br /> AT EACH DISPENSER FOR VAPOR FLOW METER, co <br /> I O J <br /> ❑ ° ® RFGSYSDTEM VEEDER-ROOT <br /> PDERFORMOVEEDERLROOT CORD STARTE AS Q&RED FOR MONI OR SYSTEM COF SMART ERTIFICATION SENSOR MODULES AND WIRELESS U <br /> ❑ [-1 ❑ I- _ <br /> REMOVE EXISTING VAPOR PRESSURE SENSOR AT DISPENSER. INSTALL NEW VAPOR PRESSURE SENSOR KIT AT VENT STACK. REFER O <br /> TO SHEET T-3 FOR DETAILS U O <br /> COMPLIANCE NOTES co <br /> 1. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BEFORE STARTING ANY WORK. ANY W <br /> DISCREPANCY SHALL BE CALLED TO THE ATTENTION OF THE OWNERS CONSULTANT FOR HIS DECISION BEFORE PROCEEDING WITH <br /> A B THE WORK. <br /> EXISTING 2" FLEXIBLE 1 2 2 2 2• GENERAL CONTRACTOR SHALL OBTAIN NECESSARY PERMIT FROM APPLICABLE AGENCIES FOR EXCAVATIONS OF TRENCHES 5'-0" <br /> DOUBLE WALL PRODUCT 3 OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND. LL_ <br /> PIPING REMOVE EXISTING <br /> EXISTING 4" OVER 3" DISPENSER AND 3. ALL MATERIALS SHALL BE COMPATIBLE WITH USE FOR THE INTENDED PURPOSE AS PER NATIONALLY RECOGNIZED CODES, LOCAL <br /> REPLACE WITH NEW CODES AND GOVERNING AUTHORITIES. <br /> DOUBLE WALL FIBERGLASS GILBARCO ENCORE 700SXISTING 4• ALL MONITORING DEVICES SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. <br /> VAPOR RECOVERY SERIES (TYP. OF 6) VENT <br /> RISERS 5. PRIOR TO FUEL BEING PUWPED, STATION MUST HAVE VEEDER ROOT FUNCTIONAL AND MONITORING ANNULAR SPACES OF TANK <br /> AND DISPENSER SUMPS. <br /> I <br /> 6. EVIDENCE OF FINANCIAL RESPONSIBILITY SHALL BE SUBMITTED TO GOVERNING AGENCY (BY COSTCO), IF REQUIRED. <br /> � - - - - - 7• 2305.6 WARNING SIGNS WARNING SI GNS SHALL BE CONSPICUOUSLY POSTED WITHIN SIGHT OF EACH DISPENSER IN THE <br /> FUEL-DISPENSING AREA A,ND SHALLSTATE THE FOLLOWING: <br /> EXISTING TANK ANNULAR _ 1. NO SMOKING. <br /> (TYP. OF 4) EXISTING 2. SHUT OFF MOTOR. <br /> TANK #1 3. DISCHARGE YOUR STATIC ELECTRICITY BEFORE FUELING BY TOUCHING A METAL SURFACE AWAY FROM THE NOZZLE. <br /> EXISTING FILL SUMP (87 OCTANE) EXISTING 4. TO PREVENT STATIC; CHARGE, DO NOT REENTER YOUR VEHICLE WHILE GASOLINE IS PUMPING. -o o _ o <br /> (TYP. OF 3) '-- i- v 4 20,000 5. IF A FIRE STARTS, IDO NOT REMOVE NOZZLE-BACK AWAY IMMEDIATELY. o H z -6 z o <br /> - _ GALLON TANK #4 6. IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE INTO UNAPPROVED CONTAINERS. m <br /> - --- C} ADDITIVE7. NO FILLING OF PORTABLE CONTAINERS IN OR ON A MOTOR VEHICLE. PLACE CONTAINER ON GROUND BEFORE FILLING. _ '� N <br /> jEXISTING 1 ,500 GAL. < <br /> TANK #2 8. 2305.5 FIRE EXTINGUISHERS. APPROVED PORTABLE FIRE EXTINGUISHERS COMPLYING WITH SECTION 906 WITH A MINIMUM RATING <br /> p (87 OCTANE) -- OF 2-A:20-B: C SHALL BE PROVIDED AND LOCATED SUCH THAT AN EXTINGUISHER IS NOT MORE THAN 75 FEET (23 860 MM) m N N M <br /> 20,000 FROM PUMPS, DISPENSERS OR STORAGE TANK FILL-PIPE: OPENINGS. o a <br /> M o <br /> GALLON - - <br /> 9• INSTALLATION SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF CHAPTER 23, 2013 CALIFORNIA FIRE CODE. c Y o o <br /> - EXISTING d ° t a 6 <br /> j TANK #3 0 0 " a o <br /> (92 OCTANE) -- UTILITY CONFLICT NOTE <br /> I 20,000 = 0 0 <br /> " p GALLON CAUTION Z > '2 <br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE CAUTION! POTENTIAL UTILITY CONFLICT. CONTRACTOR SHALL p z N <br /> - - - LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING U11U11ES FIELD VERIFY ALL EXISTING AND NEW UTILITIES PRIOR TO N a J <br /> XISTING DOUBLE WALL WHETHER SHOWN ON THESE PLANS OR NOT BY POTHOLING THE CONSTRUCTION. SEE UTILITY CONFLICT NOTE w <br /> x <br /> FIBERGLASS TANKS U11UTIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATIONQ z z <br /> // / ` • -- - - (TYP.) PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING U11UTY THE EXISTING WATER, STORM, AND SANITARY SEWER SERVICE SHOWN IS w g <br /> APPROXIMATE, BASED ON FIELD SURVEYS AND AS-BUILT" RECORDS. N z E <br /> j • - - - -� LOCATE © (800) DIG-RITE AND THEN POTHOUNG ALL OF THE THE GENERAL CONTRACTOR SHALL "POTHOLE" THE EXISTING UTILITIES ¢ r'`) N N c50 17, <br /> XISTING TURBINE SUMP EXISTING UTIUTIES AT LOCA11ONS OF NEW UTIUTY CROSSINGS TO o N o0 z � <br /> TYP. OF 3 TO VERIFY THE DIAMETER AND LOCATION (INCL. ELEVATIONS) PRIOR TO o ao (0 00 cr z o <br /> J1 ( ) PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS CONSTRUCTION. ANY DISCREPANCIES IN THE LOCATION OF THE z � w w <br /> i OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON N I I w <br /> i <br /> EXISTING PIPE OR INCOMPATIBILITY OF THE DESIGN SHALL BE Q ? <br /> � - <br /> UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIAl10N. � `s in in co z <br /> BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNERS REPRESENTATIVE, N N z _ <br /> IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT rn <br /> EXISTING VENT RISERS AND BARGHAUSEN CONSULTING ENGINEERS (425-251-6222). z ^^ _j > <br /> BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL N z � � w > m <br /> -- PROBLEMS PRIOR TO PROCEEDING WTH CONSTRUCTION. co w dN > j o <br /> N <br /> SHEET INDEX: w <br /> _ J <br /> 1 OF 5 DISPENSER AND SENSOR REPLACEMENT SITE PLAN (v',N ''s� 463 <br /> 2 OF 5 DISPENSER DETAILS <br /> y z <br /> --- <br /> 3 OF 5 VAPOR PRESSURE SENSOR KIT DETAILS Q z <br /> 4 OF 5 ELECTRICAL SITE PLANuj <br /> ' --------- - - ---------- -- ----- - - ------ - --------------- -------- 5 OF 5 VEEDER-ROOT WIRELESS DETAILS <br /> I � yJv S <br /> DRAWING DISCLAIMER NOTE b8 �O`' s <br /> THIS SITE PLAN HAS BEEN PREPARED WITHOUT BENEFIT OF TITLE REPORT, E <br /> SURVEY, OR LEGAL DESCRIPTION. BARGHAUSEN CONSULTING ENGINEERS DOES <br /> NOT WARRANT THE ACTUAL LOCATION OF PROPERTY LINES AND SETBACKS NOR o <br /> THE LOCATION OF EXISTING UNDERGROUND PIPING AND EQUIPMENT. IT IS THE a i <br /> m <br /> Cal <br /> RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO VERIFY PROPERTY LINES mLL <br /> DISPENSER AND SENSOR REPLACEMENT SITE PLAN <br /> SCALE: �- �' 811 AND SETBACK DISTANCES WHERE THEY MAY AFFECT THE PLACEMENT OF NEW .0 n O o <br /> 0 5 10 20 TWO EQUIPMENT AS A PART OF THIS PROJECT. THE DRAWING REFLECTS EXISTING 0 r <br /> eff� YOU SITE CONDITIONS AS PROVIDED BY COSTCO FROM ARCHIVE RECORDS. <br /> DIG <br />
The URL can be used to link to this page
Your browser does not support the video tag.