Laserfiche WebLink
s, <br /> z, <br /> BUILDING OUTLINE - <br /> SEE SITE PLAN FOR -- <br /> EXACT CONFIGURATION <br /> B�CTR , <br /> ICA` Roo <br /> _.. -.. DATA __. <br /> CASHIER - - <br /> _ M <br /> INTERCOM _ MONITORING <br /> ELECT <br /> WREvrgIV AL <br /> -,-�='fir r✓✓✓,r•/ij'-'/_ ��a'�, - - <br /> C ; <br /> FOR REFERENCE ONLY <br /> THIS DIAGRAM IS SCHEMATIC <br /> SEE ELECTRICAL SITE PLAN FOR ACTUAL CONDITIONS. <br /> - " ACTUAL CONDUIT RUNS SHALL CONFORM TO THE NATIONAL <br /> ELECTRIC CODE AND FIELD CONDITIONS <br /> SEE SITE PLAN FOR EXACT LOCATION <br /> OF DISPENSER CONTAINMENT SUMPS <br /> NOTES <br /> 1. DON'T CROSS PRODUCT PIPING EXCEPT AT 90', KEEP ALL ELECTRICAL CONDUITS OUT OF <br /> PRODUCT PIPING TRENCHES. <br /> Z CONDUIT LOCATED WITHIN THE TANK HOLE MUST BE WRAPPED OR COATED RIGID STEEL, <br /> 3, BELDEN CABLE MUST BE USED FOR ALL MONITORING EQUIPMENT. (NO ALTERNATE) <br /> P 4. USE CONDUIT SPACER SUPPORTS EVERY 8'-0" O.C. - <br /> 0 <br /> \ <br /> di '^ ` LEGEND <br /> U I � • <br /> I I V 1 <br /> ti <br /> 1" DATA CONDUIT (DISPENSER) <br /> 3/4- ELECTRICAL CONDUIT (TANK) <br /> 4� � <br /> u g. f <br /> 1" ELECTRICAL CONDUIT (DISPENSER) d <br /> 'I " <br /> 1" MONITORING CONDUIT (HOMERUN <br /> ) — - — - — - <br /> CONDUIT FRODISPENSERSp AND BETWEEN SUMPS) <br /> h — - — - — <br /> m r r <br /> f ; II 3/4' INTERCOM CONDUIT _______________________________ <br /> - Chevron U.S.A. Inc. ("Chevron') owns the copyright rights to the design of the herein described fueling <br /> M <br /> system as embodied In any tonyible or electronic medium of expression including all building <br /> V1 N),e Aped �, r r - ' designs, orchlleclural plans and drowings. The copyrighted material includes the overall form as well os <br /> _ I the arrangement end composition of spaces and elements In the design, but does not include Individual <br /> - " E standard features. Anyone who wishes to copy, distribute or sell this drawing a any derivative works <br /> PLAN ft <br /> SEES 0 <br /> �LIvJ r EXACT INSTALLATION LOCATION based hereon must have the prior written consent of Chevron, except for copies made for the sole <br /> US purpose of preparing construction drawings for Chevron branded facilities and all such copies shall be 4 <br /> NIF Ap OF STORAGE TANKS, returned to Chevron upon request. <br /> ©1995 Chevron U.S.A. Inc. All rights reserved. ' <br /> RFCU The drawings, calculations, and any specific reference to equipment, materials or components, <br /> if Included herein, are generic and not designed for site specific applications. Chevron does not warrant <br /> N Ie A(]N or guaranty the accuracy, completeness, rnerchontabilty, intended use or applicability of such drawings, <br /> e� calculations, and any referenced equipment, materials or components, to the requirements or Q <br /> needs of your site or local area. Consult a registered architect or professional engineer to determine <br /> any site specific design, applicability, accessibility, building code, municipal requirements and any and (' <br /> oil applicable federal, slate and local statutes, rules and regulations which may effect your site, Le <br /> Chevron does not provide these services, <br /> UNDERGROUND ELECTRICAL CONDUIT ISOMETRIC_ IoM, UNDERGIRWO ELECTRICAL <br /> Y SCALE: NONECONUNTSCHROTIC <br /> Z <br /> chuyion 9-4275 <br /> C4 <br /> Marketing 2905 W. BENJAMIN HOLT DR. <br /> STOCK7ON, CA. <br /> a <br /> Rovlekfie <br /> SCALEf' AS SHOWN �..DAT& IOSEP96 <br /> "- DR - CFL -<-W APP - C <br /> SHEET 4, <br /> F-80 <br /> 8235.21: <br /> FOR REFERENCE ONLY, EXISTING TANKS TO REMAIN <br /> OCT 0 9 1996 <br />