Laserfiche WebLink
SPECIFICATIONS <br /> 48 48' <br /> HIGH HOSE RETRACTOR HIGH HOSE RETRACTOR <br /> HOSE BREAKAWAY HOSE BREAKAWAY <br /> 65 F 67 DISPENSER • EXPLOSION PROOF JUNCTION BOX <br /> FILTER SEAL OFF <br /> ❑❑ <br /> 1 1/2"0 SCH, 40 BLACK IRON 'PIPE CAP WITH HOLE FOR O1 m <br /> PIPE RISER CONTAINMENT PROBE WIRE <br /> 1 1/2" N.P.T. INLET UNION <br /> (BY DISPENSER MFG.) SEAL ALL OPENINGS WA TER TIGHT <br /> - _ <br /> FILTER CHANGE TRIP TRAY - _ SLOPE CONCRETE DISPENSER NOZZLE 68. DISPENSER NOZZLE 68 <br /> (BY DISPENSER MFG.) - 1 1/2" PER FOOT ❑ ❑ ❑- DISPENSER NOZZLE SWIVEL zz <br /> AWAY FROM DISPENSER NOZZLE SWIVEL <br /> 71 OPW DUAL POPPET IMPACT VALVE — DISPENSER (TYP.) <br /> (SHEAR SECTION TO BE FLUSH <br /> WITH TOP OF DISPENSER ISLAND) . 44a <br /> a Q p O 4 4 4.• r. <br /> A <br /> I a ' <br /> NOTE� <br /> 3/41' P.V.C. PUMP OUT PIPE I < STABILIZER BAR 7; NOTE'1. DISPENSERS SHOWN HAVE A SIDE HOSE MOUNT. 1. DISPENSERS SHOWN HAVE A SIDE HOSE MOUNT, <br /> WITH THREADED P OUT <br /> BRACKET EXTENSION TOP HOSE MOUNT IS ALSO AVAILABLE. TOP HOSE MOUNT IS ALSO AVAILABLE. <br /> SUMP PENETRATION BOOT 0® - 2. SUPREME SIDE OF DISPENSER MUST ALWAYS BE ON THE LEFT, 2•SUPREME SIDE OF DISPENSER MUST ALWAYS BE ON THE LEFT, <br /> 89 F.R.P. DISPENSER CONTAINMENT SYSTEM FOR CONDUIT — __ - --- - <br /> 45' BLACK IRON ELBOW 1' CONDUIT TO CONTROL <br /> I PANEL (POWER) 2 DISPENSER ELEVATION — DRESSER WAYNE V490 67 66 <br /> 1 DISPENSER ELEVATION — DRESSER WAYNE XV390 <br /> 0 0 — I' ONDUI TAO CONTROL L 1/2'=1'-0" <br /> ° ° 1 Z. <br /> 3/4" CONDUIT TO CONTROL <br /> — — PANEL (SPEAKER) SIDE "B° <br /> —3/4" CONDUIT FOR CONTAINMENT _ 48 ' <br /> I BOX PROBE TO MONITOR PANEL - - <br /> 0 2 1/2" MINIMUM CLEARANCE I —BRACKET 24" 24" <br /> BETWEEN FITTING & PIPE (DO NOT PENETRATE SUMP) 21" 21" <br /> 18 ^ /lY@-/ill r ( �• 2" P.V.C. PIPE OPEN AT BOTTOM. 10 1 2' 10 1 2" 9" <br /> (� 2"0 F.R,P. PIPE ATTACH TO CONTAINMENT BOX <br /> 9 / 1/2" N.P.T <br /> `\]/ AS NEEDED FOR SUPPORT 3/4" x 1 1/2" <br /> �. 16" 16" 2 1/Y' CONDUIT <br /> 19 3"e F,R.P. PIPE O SLOTS (8) (SPEAKER OPT.) <br /> DISCRIMINATING SENSOR 88 pROVIOED <br /> 1 1/2'"M SWIVEL x 2"F i 24" FOR ANCHOR - <br /> SUMP PENETRATION BOOT FLEXIBLE CONNECTOR, ALTERNATE 75 BOLTS I 1 <br /> MINIMUM MINIMUM FLEXIBLE CONNECTOR WITH ELBOW - 1 <br /> CLEARANCE CLEARANCEQ3" TO Y REDUCER BOOT - 1" N,P.T. VAPOR <br /> BETWEEN WITH TEST PORT RECOVERY OUTLET – �— – <br /> PIPE PIPE ACK BOOT AFTER TESTING} USE APPROVED NON–HAROENING <br /> (ROLL BNOTE; t (PREFERRED LOCATION) s <br /> JOINT COMPOUND <br /> FOR THREADED CONNECTIONS. I – 2 4' n n <br /> — ' _ —' r <br /> PRODUCT -- 2" BELL & MALE F R.P. r9 .. _ - a w . <br /> THREADED ADAPTOR - 4 1 4 1Z00 <br /> _ <br /> w <br /> - - I <br /> I <br /> 3" 3" 1" 1 VAPOR <br /> RECOVERY OUTLET <br /> HI OCTANE lO" (ALTERNATE LOCATION) <br /> MID OCT SIDE 'Ar 1 1ET N.P.T. <br /> V 471 LOW CT <br /> NOTE: LOW OCTANE <br /> DISPENSER 9. CONTRACTOR TO FIELD VERIFY DISPENSER BASE DIMENSIONS, <br /> 2.PRODUCT ORDER SHOWN IS TYPICAL, NO OTHER VARIATIONS ARE ACCEPTABLE, I" N.P.T. CONDUIT <br /> GENERAL CONTRACTOR TO PRONDE - <br /> Ii PIPING TO EACH VAPOR RECOVERY �— <br /> MANIFOLD - <br /> DISPENSER BASE — DRESSER WAYNE XV390 <br /> 71 1 1/2" x 1' OPW DUAL POPPET 1 1/2'=1'-O" <br /> VAPOR SHUTOFF VALVE <br /> (SHEAR SECTION TO BE FLUSH \� SIDE xBx <br /> WITH TOP OF DISPENSER ISLAND) <br /> 48" <br /> . 24" — 2421 21" „ <br /> m e <br /> :4' dd d 10 1/2” 10 1/2•, 9„ 1 2" N P <br /> 9" / T. <br /> o n . • » ".� d 3/4" x 1 1/2" y,. /,. I 7„ 2 1�2:TT " CONDUIT <br /> N SLOTS (B) —Z, 2 I (SPEAKER OPT.) . <br /> j FOR ANCHOR <br /> 45' BLACK IRON ELBOW PROVIDED I_ <br /> BOLTS I <br /> I I 1 t I I <br /> 6" MINIMUM PEA GRAVEL - - <br /> COVER OVER F.R,P. PIPE --7 1/2"M SWIVEL x 2"F x 24" <br /> 00 y. FLEXIBLE CONNECTOR <br /> y NOTE,. •` r . <br /> USE APPROVED NON–HARDENING I. <br /> U JOINT COMPOUND FOR THREADED <br /> Us CONNECTIONS. - M – <br /> — _ <br /> 20 2"0 F.R,P. VAPOR RECOVERY PIPE 2" BELL & MALE F.R.V, co O – 1 – _ T00 <br /> W THREADED ADAPTOR — <br /> o SUMP PENETRATION BOOT - <br /> 777 O,jt Nb ( �j"7vr�-/vl l7}� I Chevron U.SA, Ina. ("Chevron") owns the copyright rights to the design of the herein described fueling > <br /> 0 1 3" 1 1/2" N.P.T. system as embodied in any tangible or electronic medium of expression including all building O <br /> / <br /> IN <br /> (3) designs, architectural plans and drawings. The copyrighted material includes the overall form as well as <br /> 11 - 13 1/2" the arrangement and composition of spaces and elements in the design, but does not include Individual <br /> NOTE. 3 1 4' .. <br /> 1. MOUNT VAPOR SHUTOFF VALVE USING PHIL-'RTE VAPOR RECOVERY - 1" N.P.T. VAPOR DIESEL standard features. Anyone who wishes to copy,consent <br /> of Ce or sell This drawing ie any derefor the warps <br /> RECOVERY OUTLET based hereon must have the tion written dfor Ch r Chevron, except for copies made for she sole Q. <br /> VAPOR IMPACT VALVE SUPPORT rot SIDE •A" I" N.P,T. CONDUIT purpose of preparing construction drawings for Chevron brooded facilities and all such copies shall be Q <br /> LOW OCTANE returned to Chevron upon request. <br /> NOTE! MID OCTANE ©1995 Chevron U.S.A. Inc. All rights reserved- <br /> T <br /> 1, CONTRACTOR TO FIELD VERIFY DISPENSER BASE DIMENSIONS. HI OCTANE The drawings,herein, <br /> are ge, and any specific reference to equipment, moteriols or components, <br /> if included herein, era generic and not designed For site specific oppllcation s. Chevron does not warrant <br /> cc <br /> 2.PRODUCT ORDER SHOWN IS TYPICAL, NO OTHER VARIATIONS ARE ACCEPTABLE. - or guaranty the accuracy, completeness, merchantability, intended use or applicability of such drawings, Q . <br /> y referenced equipment, materials or components, to the requirements.or <br /> needs of <br /> and on <br /> 4 needs of your Site or local area. Consult a registered architect <br /> code or professional engineer to determine <br /> 5 any site specific design, le and lova statutes, <br /> accessibility, building code, municipal may affects and any and <br /> DISPENSER CONNECTION AND PIPING (HARD) DISPENSER BASE — DRESSER WAYNE V490 <br /> all applicable federal, state and local stoluses, rules and regulations which may affect your site. <br /> Chevron does not provide these Services. ..! <br /> [NO SCALE —' WPENSER BUND AND MF1NQ DEI'AILP <br /> Z cheMori®e i 9-4275 <br /> a - - <br /> Marketing 2905 W. BENJAMIN HOLT DR. <br /> STOCKTON, CA. <br /> o -- <br /> i Revfalwle _ --- <br /> SCALE= t/4'-1-0' . bArEr 1 oSEP96 <br /> - DR C! ciG APP <br /> %FEF -6C <br /> i. - 8233.21 lam- <br /> FOR REFERENCE ONLY. EXISTING DISPENSERS ARE WAYNE DL3-390'5' <br /> { OCT 0 9 1996 <br /> , <br />