My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1999 PLAN
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
REMOVAL_1999 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:52 AM
Creation date
11/5/2018 11:52:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1999 PLAN
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BENJAMIN HOLT\2908\PR0231021\REMOVAL PLAN 1999.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AAL <br />Ir <br />NOTE: MATERIALS LIST SHOWN CONSTITUTES ALL THE FORSEEN MATERIALS REQUIRED FOR VARIOUS PORTIONS OF THE COMPLIANCE SCOPE OF WORK. <br />SiTE SPECIFIC REQUIREMENTS WILL VARY FOR EACH LOCATION AND GOVERNING JURISDICTION REQUIREMENTS WILL VARY, CONTRACTOR IS <br />RESPONSIBLE FOR PROVIDING ALL MISCELLANEOUS EQUIPMENT, FITTINGS, MATERIALS AND DEVICES NECESSARY TO PROVIDE A COMPLETE <br />AND OPERABLE SYSTEM IN COMPLIANCE WITH ALL JURISDICTIONAL REQUIREMENTS. <br />O <br />.�( O <br />lV 0 0 9 ICOh <br />PIS <br />0 w CL <br />' <br />0" <br />V <br />ppyyo� Q <br />V✓I <br />4, Pl` <br />!V\ G �J <br />Do S .0) d <br />V o <br />/^,� <br />! 1 <br />Material List at Tank SEE NOTE BELOW <br />Material <br />List at Dispenser Island <br />p <br />SEE NOTE BELOW <br />General Notes <br />— — --- <br />i. THE UNDERGROUND TANK SHALL BE A UNDERWRITER LABORATORIES INCORPORATED <br />TANK LISTED FOR THE UNDERGROUND STORAGE OF ALL FLAMMABLE AND COMBUSTIBLE <br />MOTOR FUELS. LISTING MUST INCLUDE THE ABILITY TO WITHSTAND A VACUUM TEST <br />OF 13.8 INCHES OF HG. <br />2. UNDERGROUND TANK INSTALLATION AND TESTING SHALL BE PER U, L LISTED <br />"MANUFACTURER'S INSTALLATION INSTRUCTIONS". INSTALLATION SHALL CONFORM TO <br />NEPA-30 AND ALL APPLICABLE LOCAL AND STATE REGULATIONS. <br />©-- m � <br />C (0 <br />�J <br />! \ Q) <br />�/ <br />/"y"" c ' <br />1�,•,°1`ry1�1+ U <br />ITEM <br />DESCRIPTION <br />MANUFACTURER <br />TEM <br />DESCRIPTION <br />,MANUFACTURER <br />BLENBAL MULTI PRODUCT DISPENSERS <br />W/ BALANCE VAPOR RECOVERY <br />36" WIDE FRAME <br />"GILBARCO" ADVANTAGE SERIES MODEL '# 878 (THREE PRODUCT BLENDING MPD W/ SINGLE HOSE PER SIDE) <br />(SUPPLIED DIRECTLY TO SITE BY GILBARCO) <br />1 <br />O <br />12,000 GAL DOUBLE WALL GIASSTEEL TANK <br />10,000 CAL DOUBLE WALL GIASSTEEL TANK <br />"MODERN WELDING" - EXISTING TO REMAIN - <br />"MODERN WELDING" - 8- 10000 ARCO CONFIGURATION (NEW) <br />27 <br />O <br />COAXIAL DISPENSER NOZZLE <br />(VENTURI STYLE) <br />EMCO WHEATON MODEL ({ EW-N4005UF <br />O--' <br />- � <br />42" TURBINE <br />SIDE CONTAINMENT SUMPS <br />(SEE DET. #2 DWG. TK3 1) <br />- - - - <br />TO <br />MODERN WELLING' SUMPS <br />FIELD INSTALL NEW SUMPS <br />COAXIAL FUEL HOSE (VENTURI STfLE) <br />8'-0" GOODYEAR VENTURI STELE MODEL # GY-MXP96-31 <br />- - <br />O <br />MECHANICAL LEAK DETECTOR <br />3 G P.H. <br />"VAPORLESS' MODEL #LD -2000 (NEW) <br />- , ' <br />28 <br />8'-0" LONG W/ 12" WHIP <br />12" WHIP - GOODYEAR MODEL # GY MX12 <br />3. MONITOR SYSTEMS FOR THE INTERSTICE SHALL BE: BY A VEEDER ROO"T LIQUID SENSOR,ZX� <br />AND IN ACCORDANCE WITH APPLICABLE LOCAL AND STATE REGULATIONS, <br />4. BEDDING AND BACKFILL MAY BE SAND, PEA GRAVEL, ROUNDED AGGREGATE CRUSHED <br />STONE OR NATIVE SOIL IN ACCORDANCE WITH MANUFACTURER'S CURRENT INSTALLATION <br />INSTRUCTIONS AND ARCO SPECIFICATION 13800. <br />5, THE DESIGN, ASSEMBLY, AND TESTING OF THE PIPING SYSTEM SHALL BE IN CONFORMANCE <br />WITH THE APPLICABLE SECTION OF ANSI -B31, AMERICAN NATIONAL STANDARD CODE <br />PRESSURE PIPING, AND NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE. <br />6. ALL ASSOCIATED PIPING SHALL BE PROTECTED FROM CORROSION. <br />�V�. <br />Ey <br />cd <br />J <br />29 <br />FUEL HOSE BREAKAWAY VALVE <br />' a <br />HUSKY" MODEL j� HS-3..60VR <br />OW/ <br />42 DIA. MANHOLE (RAINTIGHT) <br />MANHOLE SKIRT AND <br />LIFTING HANDLE <br />'FIBERLITE" MODEL # FL 42 (WITH BLACK COVER - NO SUBSTITUTES) <br />'FIBERLITE' MODEL # FL 42SK-9G (SKIRT) <br />"FIBERLITE" MODEL # FL -HANDLE (SHIP ONE PER SITE) <br />30 <br />PRODUCT IMPACT VALVE <br />DOUBLE POPPET <br />W/ FUSIBLE LINK <br />"OPW" MODEL # 10-BHMP-5830 <br />OEXTRACTOR <br />VENT VALVE 4"x4"x2"x2" <br />W/ 12" BALL FLOAT VALVE <br />"DPW" MODEL # OPW-23.3VM-4422 EXISTING TO REMAIN (TANKS #1& #2) (NEW ON TANK #3) <br />"DPW" MODEL # OPW-53VML-0120 <br />31 <br />VAPOR RECOVERYFOR <br />IMPACT VALVE (TOP ENTRY) <br />DPW" MODEL # 60VSPC-1001 <br />i <br />O <br />RISER ISOLATION JACKETS <br />"WEAVER" MODEL #R!K-J6x48x4'IPS-1 <br />7. SEE DRAWINGS FOR NUMBER OF FITTINGS, CONFIGURATION, ACCESSORIES AND SUMP <br />RISER DETAILS. <br />4% <br />.� <br />Q <br />32 <br />1-1/2" x 24" FLEX CONNECTOR <br />SWIVEL MALE x FEMALE 2" <br />w/ ISOLATION JACKET <br />TITEFLEX MODEL # 111430-24-0240 (U.L LISTED) w/ "GUARDFLEX" ISOLATION JACKET <br />07 <br />VENT CAP <br />"DPW" MODEL # OPVJ 523LP-2203 EXISTING TO REMAIN <br />34 <br />UNDER DISPENSER SPILL <br />CONTAINMENT SUMP 36' BASE <br />"TOTAL CONTAINMENT" MODEL #DX 3016 (SHALLOW PAN) <br />WITH STABILIZER ASSEMBLY <br />(CONTRACTOR TO PLUMB ALL FITTINGS) <br />n <br />Abbre__v_ iations List <br />Abbreviations <br />_ _ <br />ABBR. DESCRIPTION ABBR. DESCRIPTION <br />- <br />O <br />TURBINE PUMP 1-1/2 H P. STD. <br />W STANDARD PUMP CONTROLLER <br />/ I, <br />- <br />RED JACKET AGE 15051 (NEW FOR ALL TANKS) <br />ORDER 7 <br />(-) SIPHON CHECK VALVES MODEL #RJ -188-233-5f: <br />-' - _ ;� _/�-' <br />UNDER DISPENSER SUMP <br />"VEEDER ROOT MODEL # VR -794380-208 <br />OTURBINE <br />TRAPPER SCREEN <br />"RED JACKET" MODEL # RJ -080-723-1 <br />36 <br />MONITORING PROBE <br />A.C. ASPHALT CONCRETE MNPT MALE NATIONAL PIPE THREADS <br />/� <br />/�Y <br />[ <br />® <br />♦ <br />I� <br />® <br />36 <br />UNDER DISPENSER SUMP <br />PRODUCT PIPING PENETRATION <br />FITTING <br />"ENVIRON' MODEL 11 PES-3520RT <br />API AMERICAN PETROLEUM INSTITUTE N.C. NORMALLY CLOSED <br />APPROX. APPROXIMATE NP NIPPLE <br />AUX. AUXILIARY NET NATIONAL PIPE THREAD <br />BLU. BLUE N0. NUMBER0 <br />BILK . BLACK N. 0. NORMALLY OPEN <br />C. CONDUIT N/A NOT APPLICABLE <br />COMB, COMBINATION N.T.S. NOT TO SCALE <br />CDIVN. CONNECTOR/CONNECTION 0. D. OUTSIDE DIAMETERFUU <br />CORP. CORPORATION P PRODUCT LINE <br />EL CENTER LINE PVC POLYVINYL CHLORICE <br />DBL. DOUBLE QTY. QUANTITY <br />D DEEP REF. REFERENCE <br />DIM. DIMENSION REQ'D. REQUIRED <br />D.C. DIRECT CURRENT SSE RIGID STEEL GALVANIZED <br />DWG. DRAWING PCS. SPECIFICATIONS <br />EMT ELECTRICAL METALLIC TUBING SCH. SCHEDULE <br />ELL ELBOW SCR'D. SCREWED <br />FT. FOOT SEC SECTION <br />FLEX. FLEXIBLE TfP. TYPICAL <br />FRP FIBERGLASS REINFORCED PLASTIC U.L. UNDERWRITERS LABORATORY <br />FNPi FEMALE NATIONAL PIPE THREAD U/G UNDERGROUND <br />F.G. FIBERGLASS V VAPOR LINE <br />GAL GALLON VAC VOLT AMP CURRENT <br />GALV. GALVANIZED V. R. VAPOR RECOVERY <br />HEX HEXAGON /V1O. VIOLET <br />WER <br />HOP. INSIDE PCOIAMETER P�,.�� ( /T ? 'THE <br />j <br />J -BOX JUNCTION BOX <br />L LONG fry° 1 <br />00AL'41N <br />MAX. MAXIMUM `� "' <br />of - y2 ,5. dA <br />MANE MANUFACTURER ff <br />�� ,l°�� <br />MIN. MINIMUM x Stn 4atr.LYOUti. <br />G' <br />'C; - .:.''I, <br />1 /5/99 REVISED FOR NEW TANK PER ARCO 2/5/99 <br />- <br />0 <br />_ (n <br />EL <br />0�..(( 0 <br />4V <br />ILL ••- <br />> <br />E © � � <br />"-= ([j _Q •0 <br />_r L Q <br />Li•.�. O -r _ <br />C � <br />� E%% ((S <br />C Edi <br />y�+� C IO / ` —j <br />, C V (� C <br />c 0 � cd 4% <br />_ <br />� : <br />0 <br />W CV ('j):2cdf <br />1 �/ <br />P HA S <br />MM�®� .y <br />W <br />2 <br />SL U <br />xNr+ ENGIN <br />-182 5 7"2Nc AND GF SOUM rs <br />18EN' WASHINGTCW 98032 <br />(425) 251-6222 <br />gCL:# (�0�9 <br />10 <br />2" x 24" L FLEX CONNECTOR <br />SWIVEL MALE x FEMALE 2" <br />"TITEFLEX" MODEL # 111430-32-0240 (0. L. LISTED) <br />37 <br />UNDER DISPENSER SUMP <br />VAPOR PIPING PENETRATION <br />FITTING <br />"ENVIRON" MODEL # SEB -1015 <br />it <br />3"X2" TEST REDUCER <br />'ENVIRON" MODEL # EP-RTR-3020 W/ TEST VALVE <br />38 <br />UNDER DISPENSER SUMP <br />CONDUIT PENETRATION <br />FITTING 3/4" <br />"ENVIRON" MODEL # FEB -3075 <br />12 <br />O <br />18" DIA INSPECTION" <br />WELL MANHOLE (WATERTIGHT) <br />POMECO" MODEL # P-110-18WT <br />LL RADIUS ISLAND FORMS <br />7 O" LONG X 4'--0" WIDE <br />"AMERICAN CONTAINMENT" MODEL # AC-IFIZFR <br />O39 <br />13 <br />INSPECTION WELL PIPE - 4" <br />SCHEDULE 40 14' LONG <br />.020" SLOTTED FACTORY CUT <br />"UNIVERSAL" MODEL # U-650-4013 EXISTING TO REMAIN' <br />_ <br />40 <br />4 "x84"x4" SCH, 40 DISPENSER <br />ISLAND TRAFFIC B0LLARD W/SIGN <br />MOUNTS (U -SHAPED) <br />( ) <br />"AMERICAN CONTAINMENT" MODEL # AC-PG48X72WB <br />14 <br />x <br />'-O <br />14 CIA. MANHOLE WITH <br />5 GALLON CONTAINMENT SUMPS <br />42 DIA. MANHOLE WITH <br />5 GALLON CONTAINMENT SUMPS <br />AND GAUGE VIEW PORT <br />V <br /># I <br />EMCO WHEATON' MODEL 1004 FOR SINGLE FILL AND VAPOR RETURN (TANKS #1 & #2) � <br />,' <br />"POMECO" MODEL # P -511C-163 FOR SINGLE FILL AND VAPOR RETURN (TANK #3) <br />,- - � - _ <br />cO <br />w <br />Q <br />O <br />Q <br />z <br />Q <br />F. 3 <br />O m <br />� a} <br />41 <br />24"x57"x3--1/2" SOH. 40 PIC <br />ISLAND CARD READER TRAFFIC <br />BOLLARD (U -SHAPED) <br />"AMERICAN CONTAINMENT' MODEL # BM-PG24X57 <br />�+ 1'. SEE NOTE BELOW <br />Material List at Building - <br />IS <br />FILL ADAPTER (TOP SEAL) <br />FILL CAP (TOP SEAL) <br />'LPW" MODEL # OPW 633-T-8075 <br />EXISTING TO REMAIN <br />'DPW" MODEL # OPW-634TT-7085 <br />ITEM <br />DESCRIPTION <br />MANUFACTURER <br />42 <br />LEAK DETECTION MONITOR CONSOLE <br />VEEDER ROOT' MODEL #TLS -350 w/o PRINTER MODEL #VR -847090-002 <br />76 <br />VAPOR CHECK ADAPTER <br />VAPOR CAP <br />"OPW" MODEL # OPW--1611-AV-1620 <br />"DPW" MODEL # OPW-1711T-7085 EXISTING TO REMAIN <br />43 <br />DISPENSER DISTRIBUTION <br />INTERFACE BOX <br />"GILBARCO° UNIVERSAL DISPENSER DISTRIBUTION BOX MODEL # PA02610000020 (DISPENSERS) <br />(SUPPLIED DIRECTLY FROM GILBARCO) - (SEE DWG TI(4-7) <br />17 <br />OVERFILL PREVENTION VALVE <br />WITH DROP TUBE <br />"EMCO WHEATON" MODEL j/ A1100-057 EXISTING TO REMAIN <br />44 <br />SCHLUMBERGE_R ACCESS MODULE <br />FOR PIC UNITS <br />"SCHLUMBERGER" SAM PIC INTERFACE UNIT <br />(SUPPLIED DIRECTLY FROM SCHLUMBERGER) - (SEE DWG. TK4-1) <br />18 <br />O <br />AT T'URB NE SIEMPOR <br />VEEDER ROOT" MODEL VR -794380-208 <br /># <br />45 <br />SITE CONTROLLER MODULE <br />_ <br />WITH (SUPPLIED CABLE FROM ALLIED) DSITE CONTROLLER D WITH UNIT) DWG TK4 1)TI0N <br />19 <br />LIQUID LEAK SENSOR <br />FOR TANK ANNULAR SPACE <br />"VEEDER ROOT' MODEL #794390-420 (FOR MODERN WELDING GLASSSTEEL) <br />46 <br />- <br />SECURITY MODULE <br />"GILBARCO" GSM SECURITY MODULE MODEL # PA0258000sxxx <br />WITH RS -232 CABLE (SUPPLIED WITH UNIT) <br />SUPPLIED DIRECTLY FROM GILBARCO SEE DWG. T(4-1 <br />( ) - ( ) <br />m <br />`- <br />JQ <br />N, <br />rr <br />,1 <br />a <br />Q <br />� <br />'2 <br />20 <br />SECONDARY CONTAINMENT PIPING, <br />FITTINGS AND GLUE KITS <br />"AMERON" DUALOY 3000 L OR "A.C. SMITH" RED THREAD II <br />/ <br />(CONTRACTOR TO PROVIDE MANUFACTURER DATA TO DESIGN ENGINEER) <br />47 <br />POS MODULE (POINT OF SALE) <br />"MSI" POS SYSTEM — ARCO CONFIGURATION (SOFTWARE SUPPLIED DIRECTLY FROM MSI) <br />(HARDWARE BY ARCO) (SEE DWG. TK4-1) <br />27 <br />PRIMARY CONTAINMENT PIPING, <br />FITTINGS AND GLUE KITS <br />"AMERON" DUALOY 3000/L OR A.O. SMITH" RED THREAD 11 <br />(CONTRACTOR TO PROVIDE MANUFACTURER DATA TO DESIGN ENGINEER) <br />48 <br />INTERCOM TO DISPENSERS <br />(CONSOLE MOUNTED AT SALES--- <br />COUNTER) <br />"3M" INTERCOM MASTER MODEL 3M -D-20 <br /># <br />(SEE DWG. TK4-1) <br />.. <br />1/15/98 <br />7.2 <br />BULKHEAD FITTING <br />"ENVIRON" 3" MODEL # FD -6300 2" MODEL # FEB -6200 <br />49 <br />EMERGENCY PUMP SHUT OFF <br />SWITCH (INDOOR AND OUTDOOR) <br />EXISTING TO REMAIN <br />SQUARE D CLASS 39001 K25 FLUSH PLATE PUSH-BUTTON W/ K60 COVER, INDOOR <br />SQUARE D CLASS 9001 KR3RH6 PUSH-BUTTON N.C. WITH I<F,G COVER IN WEATHERPROOF <br />ENCLOSURE (OR EQUAL) (SEE DWG. 7K4-1) <br />23 <br />COMPRESSION FITTING, <br />AIRTIGHT (AT SUMPS) <br />"ENVIRON" 3/4" MODEL # FEB -3075 1" MODEL # FEB -3100 <br />- <br />1/30/98 SILK <br />2q <br />2" BALL VALVE 150 WSP/600 <br />FORGED BRASS FULL PORT <br />"JOMAR" SYSTEM -4 MODEL # T-10-708 <br />-. <br />O <br />- <br />CD <br />z m <br />w ¢ <br />w <br />Z 3 <br />! <br />- 2/5/99 <br />--- <br />2133 <br />25 <br />JUNIOR BURIAL SUMP <br />(FOR 87 OCTANE LINE) <br />---� <br />'ENVIRON" MODEL #JBS-2422 \ <br />I <br />INDICATES MATERIAL SUPPLIED BY CONTRACTOR. ALL OTHER NUMBERED ITEMS ON THIS LIST SUPPLIED BY ARCO PRODUCTS COMPANY24" <br />DSITE INYUNDFAMAGED CONDITION. <br />VERIFYGEQUPMENTTCOUNTS. UCONTRACTORRSSRESPONSIBLEAFOR(VERIFYING THATALLL EQ PMENT ARRIVES ATD <br />'i. / liief <br />TK4--3 <br />26. <br />IA. MANHL <br />D87 OCTANOEELNO)ER "POMECO" <br />(FORD <br />MODEL # P-170-24WT / <br />
The URL can be used to link to this page