My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3011
>
2300 - Underground Storage Tank Program
>
PR0231883
>
REMOVAL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 9:18:52 AM
Creation date
11/5/2018 11:59:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
2004
RECORD_ID
PR0231883
PE
2351
FACILITY_ID
FA0002111
FACILITY_NAME
BEN HOLT SHELL
STREET_NUMBER
3011
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
10018010
CURRENT_STATUS
02
SITE_LOCATION
3011 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BENJAMIN HOLT\3011\PR0231883\REMOVAL 2004.pdf
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LN IED PROGRAM CONSOLIDATED FOR:si <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE Y <br /> (Two pages per tank) <br /> Page 4 of 7 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item Gray) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ® 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DIIA-Doing Business As) 3, 1 FACILITY ID: 1. <br /> Ben-Holt/I-5 Shell <br /> LOCATION WITHIN SITE(optionai) 431. <br /> 3011 W Ben`amin Holt Dr, Stockton <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK Lj Yes N No 434. <br /> 136148-Premium Xerxes If"Yes,"complete one page for each compartment <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> 1996 15,000 one <br /> ADDITIONAL DESCRIPTION(For local use only) 439. <br /> II.TANK CONTENTS <br /> TANK USE 434. PETROLEUM TYPE 440. <br /> ® L MOTOR V EHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ®Ib. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM []Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Ha=%low Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑ 4. HAZARDOUS WASTE n/a nla <br /> (Include Used oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> 2. DOUBLE WALL [34. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 1. BARE STEEL 03, FIBERGLASS 1 PLASTIC ❑5. CONCRETE E3 95,UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS!PLASTIC ❑8. FRP COMPTIBL£W/100%MET14ANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> S. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED ❑3.EPDXY LINING 0 5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER,CORROSION ❑1.MANUFACTURED CATHODIC ®3.FIBERGLASS REINFORCED PLASTIC 0 95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If A licable 2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ❑1.SPILL CONTAINMENT ❑1.ALARM ❑3.FILL TUBE SHUT OFF VALVE 2004 <br /> ❑2.DROP TU13E ❑2.BALL FLOAT ❑4.EXEMPT <br /> ❑3.STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 433. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> [12. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ❑2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456' TANK FILLED WITH INERT MATERIAL? 457. <br /> CURRENTLY IN USE _NIA gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1199)-114 http://www.unidoes.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.