My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BLACK DIAMOND
>
927
>
2300 - Underground Storage Tank Program
>
PR0231311
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2024 2:28:28 PM
Creation date
11/5/2018 12:11:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231311
PE
2381
FACILITY_ID
FA0003775
FACILITY_NAME
TIGER LINES INC
STREET_NUMBER
927
Direction
E
STREET_NAME
BLACK DIAMOND
STREET_TYPE
WAY
City
LODI
Zip
95240
APN
04903033
CURRENT_STATUS
02
SITE_LOCATION
927 E BLACK DIAMOND WAY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BLACK DIAMOND\927\PR0231311\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
12/30/2011 8:00:00 AM
QuestysRecordID
109789
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA - WATER RESOURCES CONTROL )ARD ;. <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM ` <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. "z. <br /> 0 10 <br /> MARK ONLY ❑ 1 EW PERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLO TANK <br /> ONE ITEM 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 2 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: E L FARM TANK-YES NO (A) <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY N <br /> 9� <br /> A. OWNERS TANK IDN 0 7 B. MANUFACTURED BY: <br /> C.YEAR INSTALLED 3 D. TANK CAPACITY IN GALLONS: /01 b0c) <br /> II. TANK PONTENTS IF(A.%IS MARKED,COMPLETE ITEM C.IF(A1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑2 PETROLEUMC. ❑ 1 UNLEADED ❑2 LEADED DIESEL <br /> B. <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL 6<PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY [:] 95 UNKNOWN ❑2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF / <br /> HAZARDOUS SUBSTANCE STORED A C.A.S.# `N/ C.A.S.#:AJIA <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,AD <br /> 1 BLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> A TYPE OF ❑ <br /> SYSTEM Ln 2 SI GLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL F-13 FIBERGLASS ❑4 STEEL CUD W/RBERGLASS REINFORCED PLASTIC <br /> S.TANK <br /> MATERIAL F-15 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑8 1D)%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR <br /> ❑ 1 RUBBER LINED ❑2 LINING F13 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS UNING 6 UNLINED ❑95 OWN'-�(� <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO 990TBER ��✓✓✓� <br /> D. CORROSION ❑ 1 POLYETHLENE WRAPf 1 2 TAR DR ASPHALT ❑ 3 VINYLWRAP ❑ 4 RBEGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORM ON CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE 4 4 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A Wl SINGLE WALLED A U 2 DOUBLE WALLED A U 3 UNEDTRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5ALUMINUM A�6 CONCRETE A U 7STEEL CLAD W/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURETESTING P 8 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE USED(MO/YR) 2. ESTIMATED QUANTITY OF 1 3.WAS Tf I INKFILLED WITH <br /> // <br /> / NC SUBST INING IN GALLONS I E TERIAL? YES ❑NO <br /> THIS FORM FIAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWL DGE IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> 3 o I I 3 l 1010 lo 13 <br /> CURRENT LOCAL AGENCY FACILITY ID# APP D BY ME PHONE#WITH AREA CODE <br /> Pl ' v <br /> PER IT NUMBER PENIMT ArPROVAL <br /> /ADlA I PERMIT EXPIRATION DATE <br /> N Y— <br /> CHECK# PERMIT AMOUNT I SURCHAIIQEA . FEE CODE RECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLE'SASORRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.