My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BRUELLA
>
24124
>
2300 - Underground Storage Tank Program
>
PR0231528
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2024 4:06:31 PM
Creation date
11/5/2018 12:21:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231528
PE
2361
FACILITY_ID
FA0003795
FACILITY_NAME
LIBERTY RURAL FIRE DISTRICT
STREET_NUMBER
24124
Direction
N
STREET_NAME
BRUELLA
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
00731024
CURRENT_STATUS
02
SITE_LOCATION
24124 N BRUELLA RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BRUELLA\24124\PR0231528\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
1/24/2012 8:00:00 AM
QuestysRecordID
111308
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> )� FORM `B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK PERMIT APPLICATION INFORMATION -° <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> TANK Zo <br /> MARK ONLY 1 NEW PERMIT r_�3 RENEWALPERMIT ❑ 5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT F-14 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 0 ' N <br /> 3 <br /> , FARMTANK-YES❑ NO <br /> .L . I . <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: '/ N <br /> I. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: AUSCO <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: sZJ <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A7),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL F-1 2 PETROLEUM B. C. 1 UNLEADED ❑2 LEADED - 3 DIESEL' ISI <br /> ❑3 CHEMICAL PRODUCT F-1 4 OIL 1 PRODUCT ❑4 GASAHOL 5 JET FUEL 6 AVIATION GAS <br /> 5 HAZARDOUS ❑80 EMPTY E]95 UNKNOWN 2 WASTE <br /> 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> I <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.R: A <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.9 <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A TYPE OF 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED F-1 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEUIRON F-1 2 STAINLESS STEEL ❑3 FIBERGLASS 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE 6 POLYVINYLCHLORIDE 7 ALUMINUM 8100%METHANOL COMPATIBLE FRP <br /> MATERIAL MATER <br /> 9 BRONZE 10 GALVANIZEDSTEEL ❑95 UNKNOWN 99 OTHER , <br /> 1 RUBBER LINED 2 ALKYD LINING F-13 EPDXY LINING 4 PHENOUC LINING <br /> C. INTERIOR <br /> LINING 5 GLASS LINING P/6 UNLINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? Ej YES 0 NO 0 99 OTHER <br /> D. CORROSION ❑1 POLYETHLENEWRAP 2TAR OR ASPHALT 3VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION 0 5 CATHODIC PROTECTION 91 NONE 95 UNKNOWN E-]99 OTHER <br /> IV. PIPING INFORMATION CIRCLE IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A(U 1 SUCTION A PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A 94 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> ,_Y, LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> AAP S I VISUALCHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 7 PRESSURE TESTING P 8 91 NONE 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LASTSED(MONA) 2. ESTIMATED DUAN ITY OF 3,WAS TAN FILLED WITH <br /> SUBSTANCE NK G IN INERT L? [:]YES ❑ NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJ RY,AND TO THE BEST OF MY KNOWLEDG ,IS TRUE AND CORRECT, <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION k AGENCY k FACILITY ID R TANK ID N <br /> I 7-1k I p lo 04- <br /> [CH!ECK <br /> RRENT LOCAL AGENCY AGILITY IDN APPROVE BYN E PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APP OV L ATE PERMIT EXPIRATION DATE <br /> o <br /> N PERMR AMOUNT SURCHARGE ANT, FEE CODE SECEIPTN BY: <br /> FORM B(6-29-8$) THIS FORM MUST BE ACCO BY A FACILITY/SITE APPLICATION, FORM W UNLESS�I^URRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />