My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BUCKLEY COVE
>
4950
>
2300 - Underground Storage Tank Program
>
PR0231028
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 9:02:51 AM
Creation date
11/5/2018 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231028
PE
2361
FACILITY_ID
FA0003811
FACILITY_NAME
RIVER POINT LANDING MARINA-RESORT*
STREET_NUMBER
4950
STREET_NAME
BUCKLEY COVE
STREET_TYPE
WAY
City
STOCKTON
Zip
95219
APN
11820001
CURRENT_STATUS
01
SITE_LOCATION
4950 BUCKLEY COVE WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BUCKLEY COVE\4950\PR0231028\BILLING 1987 - 2005.PDF
QuestysFileName
BILLING 1987 - 2005
QuestysRecordDate
12/11/2017 11:11:29 PM
QuestysRecordID
3745759
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN — Page 2 of 2) <br /> VI. UNDER DISPENSER CONTAINMENT(UDC) MONITORING (Check all <br /> that appityl <br /> UDC MONITORING IS PERFORMED USING THE FOLLOW}NG METHODS) <br /> ❑ I.CONTINUOUS ELECTRONIC MONITORING pr 2.FLOAT AND CHAIN ASSEMBLY ❑ 3,ELECTRONIC STAND-ALONE 1'"4ea' <br /> ❑ 4.NO DISPENSERS ❑ 99 OTHER(Specify) <br /> -- --- iV145( <br /> LEAK MONITOR MANUFACTURER 4`"135 MODEL#: <br /> LEAK SENSOR MANUFACTURER: 4'ML51 MODEL#(St 49.r4sn <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. ❑ a,YES .NO a'N45D <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES (r--.r ,NO a'"""' <br /> FAILUREIDISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a L=1 YES b.NO 4`11 <br /> UDC MONITORING STOPS THE FLOWOVRODUCT AT 111E DISPENSER Er-a YES ❑ b NO a'"2UDC CONSTRUCTION IS L SINGLE WALL _.DOUBLE WALL <br /> IF DOUBLE WALL: +'"'�'• <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: ❑ a,LIQUID ❑ b.PRESSURE ❑ c.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENTOF THE UDC TRIGGERS AUDIBLEAND VISUAL ALARMS. ❑ a.YES ❑ b.NO <br /> VII. PERIODIC SYSTEM TESTING <br /> I.ELD TESTING. 'PHIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED <br /> LEAK DETECTION(ELDMUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS RE UI RED.h;CCR 41ru.q <br /> ® 2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. <br /> ® 3 SPILL BUCKETS ARE TESTED ANNUALLY. a'""'r <br /> VIII. RECORD KEEPING <br /> The following mordtoring/maintenance records are kept for this facility: 49""`" <br /> ® a.ALARM LOGS ❑ b,VISUAL INSPECTION RECORDS ❑ c.TANK INTEGRITY TESTING RESULTS <br /> ❑ d.SIR TESTING RESULTS(and supporting documentation records) ❑ e.TANK GANGING RESULTS(and supporting documentation records) <br /> ❑ f ATG TESTING RESULTS(and supporting documentation records) ❑ g.CORROSION PROTECTION 60-DAY LOGS <br /> h.EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br /> IX. TRAINING <br /> Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties: +>tw9>s <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that amv) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) {'a <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required) c <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND a'A'09 <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> ❑ SWRCB PUBLICATION:-UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 491''9). <br /> 4Y1 'A <br /> ❑ OTHER(Specify). 49""Fm <br /> This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the Intemational Code Council Jy14"' <br /> (ICC. The "Designated UST Operator'will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 <br /> days of hire.This training will include,but is not limited to,the following: <br /> 1 <br /> Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> Y The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan, <br /> > The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br /> > Name(s)of contact person(s)for emergencies and monitoring alarms. <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here=w icate how many pages with additional information on specific monitoring procedures are attached to this plan. <br /> Arco.•�:r�t� XI. PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: I.)the datly/routine UST monnonng activities and maintenance of UST leak detection equipment covered <br /> by bilis plan occurs.2)all conditions that indicate a possible release are investigated;,-:13)all monitoring records are maintained properly.._ <br /> THE FOLLOWING PERSON(St ARE RESPONSIBLE FOR PERFORMING THE MONITORING AND EQUIPMENT MAIN"r P.NANCE <br /> NAME: Rwz>R ,Kr 1tBNaBEz4 4%.72. TITLE: : •t'!�/CiZ'7iC( r"4'Is <br /> NAME: 2/Q•D IwJ620-r '9"0.74. TITLE. y 4111-75W__ <br /> The Designated UST Operator shall perform a monthly visual inspection of the facility,provide a n:port to the owner/operator,and in 10M the owner/operator of any <br /> conditions that need follow-uaction. <br /> *111 NE OPERATOR SIGNATURE <br /> CERTIFICATION:1 c tify tit the io r a ro ided herein is true and accurate to the best of my knowledge. <br /> APPLICANT SIGNATU / DATE:1 9� <br /> REPRESEMIVG. Tal Ouna/O to 1 Fa91ir.Onner/O nmr _ >NM1oriiMR ramnlice of Owner J9W 76 / — �y /Z <br /> APPLICIF AME(prim) nn-- ,,� 'M4r"- APPLICANTTITLE: aNb1° <br /> Dar,-w /wtl f3 li cy S i <br /> UPCF UST-0(12/2007)-3/4 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.