My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BUCKLEY COVE
>
4950
>
2300 - Underground Storage Tank Program
>
PR0231028
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 9:02:51 AM
Creation date
11/5/2018 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231028
PE
2361
FACILITY_ID
FA0003811
FACILITY_NAME
RIVER POINT LANDING MARINA-RESORT*
STREET_NUMBER
4950
STREET_NAME
BUCKLEY COVE
STREET_TYPE
WAY
City
STOCKTON
Zip
95219
APN
11820001
CURRENT_STATUS
01
SITE_LOCATION
4950 BUCKLEY COVE WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\B\BUCKLEY COVE\4950\PR0231028\BILLING 1987 - 2005.PDF
QuestysFileName
BILLING 1987 - 2005
QuestysRecordDate
12/11/2017 11:11:29 PM
QuestysRecordID
3745759
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1r <br /> FIED PROGRAM CONSOLIDATED FORM �j TANK: TA0102806 <br /> �t IL�V 1 PR#: PRO231028 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 r FAC#: FAank) <br /> (two pages per tarok) <br /> Page 4 of 5 <br /> TYPE OF ACTION <br /> (Clack�n=�,) ❑ I NEW SITE PERMIT ❑4 AMENDED PERMIT XCHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT ..•u - ❑8 TANK REMOVED 330 <br /> BUSINESS NAME(Same as FACILITY NAME or DDA-Doing 9usiness As) FACILITY ID: PR#: <br /> RIVER POINT LANDING MARINA-RESORT* FA000381] 7 PR0231028 <br /> LOCATION WITHIN SITE(optia i) 4950 BUCKLEY COVE WAY,STOCKTON 4=1 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plat plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 6432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK [jYes E]No 474 <br /> TA0102806 "►>< If'Ycs",mmplere one Pa8e for eaeh c Panaurn. <br /> DATE INSTALLED(YEAR/MO) 411 TANK CAPACITY IN GALLONS 476 NUMBER OF COMPARTMENTS 437 <br /> 3/1/1989 12:00:OOAM 5,000 <br /> ADDITIONAL DESCRIPTION(For Ioca1 use onh) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> I.MOTOR VEHICLE FUEL ❑ 1. REGULAR UNLEADED ❑ 2.LEADED '❑ 5.JET FUEL <br /> pfmarked c pine Petrotcam T.pe) ❑ Ib.PREMIUM UNLEADED 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM © tc.MIDGRADE UNLEADED ❑ 4.GASOHOL 99.OTHER <br /> ❑3.CHEMICAL PRODUCT COMMON NAME(f Hazardous Materials Imentory page) 441 CAS#(from Hazordous Materials 1ntay page) 44, <br /> ❑4,HAZARDOUS WASTE <br /> (lneladcs Used Oil) <br /> ❑95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ ].SINGLE WALL ❑3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chxk one aem unh) EXTERIOR MEMBRANE LINER ❑ 95 UNKNOWN <br /> ® 2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-pnmary tank 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Chwk one hem anh) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/I00°/u METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99,OTHER. <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS I PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check-item onW) ❑ 2.STAINLESS STEEL 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/lW/a METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1,RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ®95.UNKNOWN 446 DATE INSTALLED 4a7 <br /> OR COATING <br /> (Chink ran:dera only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑ 6 UNLINED E]99.OTHER <br /> (For local use ante) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Chale otre item only) ❑ 4 IMPRESSED CURRENT E]99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use onh) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ® I SPILL CONTAINMENT 1,996.00 5 GAL l ❑ I ALARM ff] 3 FILL TUBE SHUT OFF VAL' <br /> ❑x 2 DROP TUBE 1,996.00 2 BALI, 1,996.00 ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A desaiptimr of the monitoring program shall be suhm ttcd w the Imal agKn ) <br /> IF SINGLE WALL TANK(Chat:all that apply) 343 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (.Chale one item unh) <br /> E] 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE [-] I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE _ <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑No <br /> UPCF(12/99 revised) <br />