Laserfiche WebLink
THE RED JACKET 3-STEP <br /> I EA TEST <br /> The lied Jacket leak detector is a pres- ing system. If a leak is present wh#ch GPM. This is the indication to the oper- <br /> suresensing,diaphragm operated valve equals or exceeds this amount, as ator that a leak is present. <br /> designed to indicate a leak in the piping much product escapes from the system If there are no leaks, pressure rapid- <br /> between the leak detector and dis- as is metered in through the leak detec- ly builds in the system forcing the leak <br /> penser, tor. Under this condition pressure can- detector to open to the full-flow posi- <br /> When the submerged pump is turned not build up in the piping system. When tion, In a system with no leaks it takes <br /> on, a controlled amount of product a nozzle is opened a poppet in the leak only two seconds for a complete test. <br /> (three gallons per hour) is metered detector moves to a position which No further line testing takes place until <br /> through the leak detector into the pip- restricts the flow to approximately 3 the line pressure drops below 1 PSI. <br /> 3 TO 4 PSI ABOVE <br /> NEAR SLIGHTLY ABOVE ATMOSPHERIC PRESSURE <br /> ATMOSPHERIC PRESSURE ATMOSPHERIC PRESSURE <br /> LESS THAN 1 PSI 8 TO 10 PSI <br /> 25 PSI ABOVE <br /> POPPET <br /> PUMP ?, PSI 1 PSI <br /> �— �— <br /> METERING. <br /> \ \PIN <br /> \\\ \\\ t <br /> LESS THAN.+, � 8 TO 10 PSI AL EQUALt,PRESSURE <br /> 1 PSI <br /> 1. THE "TRIP" OR RELAXED POSI- to 10 PSI (Instantly), the diaphragm pensers. Leaks smaller than 3 GPH <br /> TION. Under normal operating con- has moved the "poppet" to such a will be indicated by the Leak Detec- <br /> ditions, it is assumed that the lines position as to almost stop the flow for taking longer than two seconds <br /> are filled with gasoline which is es- into the piping through the leak to open completely. If there is no <br /> sentially non-compressible. When detector valve poppet. In this posi- leakage in the system, the small <br /> the system pressure is less than 1 tion, all the flow must then travel flow around the metering pin in- <br /> PSI, the diaphragm and poppet are around the metering pin which lim- creases the line pressure to 10 PSI <br /> in their "down" or "tripped'' posi- its it to approximately 3 GPH rate. in approximately two seconds at <br /> tion.The position of the valve "pop- If a simultaneous loss from the sys- which point the diaphragm will snap <br /> pet" is such as to allow approxi- tem equals or exceeds this amount, the poppet to position 3. This ail <br /> mately 3 GPM flow into the delivery the line pressure will not build be- takes place in less time than it takes <br /> line, through a bypass opening in yond this point and the valve will the dealer to reset the dispenser, <br /> the leak detector valve poppet, remain in the leak sensing position walk to the car, remove the gas tank <br /> when the submersible pump starts. with the main flow blocked. If there cap, insert and open the nozzle. <br /> Since the system is full, pressure is an attempt to dispense while the 3. NON-LEAK POSITION.This position <br /> builds instantly and the poppet valve is in this position, the line allows full flow. The poppet will re- <br /> moves to the leak sensing position, pressure will drop, the diaphragm main in this position as long as the <br /> assuming there is no leak present. will respond, and the poppet will system pressure remains above 1 <br /> 2. LEAK SENSING POSITION. As the return to position 1 where approxi- PSI. At less than 1 PSI the '`poppet'' <br /> pressure builds to approximately 8 mately 3 GPM will flow to the dis- will return to position 1. <br /> d <br /> RE0JACKET R' <br /> PUMP" <br /> A Division of Wylain, Inc. <br /> Form No. 5170 <br /> P.O. Box 3888, Davenport, Iowa 52808 <br />