My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
244
>
2300 - Underground Storage Tank Program
>
PR0231137
>
COMPLIANCE INFO 2013 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/13/2019 2:50:46 PM
Creation date
11/5/2018 12:44:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2015
RECORD_ID
PR0231137
PE
2361
FACILITY_ID
FA0001554
FACILITY_NAME
MIRACLE MILE MARKET
STREET_NUMBER
244
Direction
W
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13708014
CURRENT_STATUS
01
SITE_LOCATION
244 W HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARDING\244\PR0231137\COMPLIANCE INFO 2013 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2015
QuestysRecordDate
7/21/2016 11:31:35 PM
QuestysRecordID
3150426
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 4 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www sioov ora/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: Date: <br />244 W HARDING WAY STOCKTO I -lust 21. 2015 <br />Miracle Mile Marke. <br />UST System Observations <br />319 HSC <br />25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) <br />■ V u R m COS <br />Seconds containment not constructed to prevent water intrusion <br />❑ V ❑ R ❑ COS <br />320 HSC <br />25290.1(c3), <br />�' <br />25290.2(c3) <br />2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />o V ❑ R ❑ COS <br />321 CCR <br />322 CCR <br />2 <br />2636(1)( ) <br />Line leak detector not installed <br />o V o R ❑ COS <br />2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V ❑ R ❑COS <br />323 CCR <br />2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />o V ❑ R ❑ COS <br />CCR <br />324 <br />2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V ❑ R ❑COS <br />325 CCR <br />2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V ❑ R ❑ COS <br />326 CCR <br />327 CCR <br />2635(b)(2) <br />Overfill prevention was overridden <br />❑ V ❑ R ❑COS <br />328 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V ❑ R ❑COS <br />❑ V ❑ R ❑COS <br />329 <br />CCR 2717.1(9) <br />Tampered with red tag <br />330 <br />OR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑COS <br />331 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />o V o R ❑COS <br />332 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />o V ❑ R :COS <br />333 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements _ <br />❑ V ❑ R o COS <br />334 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V o R o COS <br />Non-Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre-Jan 1984) not performed <br />o V o R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre-January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />o V o R c COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />mV ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />o V o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />The current <br />financial responsibility documents have not been submitted to the EHD. Current financial responsibility <br />documents are required to be submitted annually. Immediately log into the California Environmental <br />Reporting System <br />(CERS) at http://cers.calepa.ca.gov/, <br />and upload the required documents. <br />This is a minor violation. <br />Received by <br />(Initial): <br />Inspector: <br />CINDY VO, EH Specialist <br />Phone: <br />(209) 468-8257 <br />Date: <br />08/21/2015 <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.