Laserfiche WebLink
„ECEIVED <br />SWRCB, January 2006 <br />Spill Bucket Testing Report FormSEP 16 2015 <br />This form is intended for use by contractors performing annual testing of UST spill coo' t�{y��.�rnmpleted form and <br />printouts from tests (if applicable), should be provided to the facility owner/operator I � Hg wrgulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: MIRACLE MILE MART I Date of Testing: 8-21-2015 <br />Facility Address: 244 W HARDING WAY STOCKTON CA <br />Facility Contact: RAY Phone: <br />Date Local Agency Was Notified of Testing :7-23-15 <br />Name of Local Agency Inspector (i(present during testing): CINDY <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: AFFORDA TEST 416 2nd Street Galt, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician Conducting Test: ❑ Lyle D. Nimmo ❑ Zane A. Nimmo ® David A. Winkler ❑ Felix G. Ramirez <br />5249115 -UT 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials': ® ICC Service Tech. ® SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: h20 and tape measure <br />Equipment Resolution: 1/16 <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc. <br />1 87 <br />2 91 <br />3 1, <br />4 <br />Bucket Installation Type: <br />® Direct Bury <br />E]Contained in Sump <br />®Direct Bury <br />E]Contained in Sump <br />E] Direct Bury <br />❑ Contained in <br />Sum <br />Direct Bury <br />❑Contained in <br />Sum <br />Bucket Diameter: <br />11 <br />I 1 <br />Bucket Depth: <br />13 <br />13 <br />Wait time between applying <br />vacuum/water and start of test: <br />Test Start Time (T,): <br />9 <br />9 <br />Initial Reading (Rl): <br />12.59 <br />12 <br />Test End Time (TF): <br />335 <br />335 <br />Final Reading (RF): <br />10 <br />10 <br />Test Duration (TF — T,): <br />1 HR <br />1 HR <br />Change in Reading (RF - R,): <br />0 <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />1/16 <br />1/16 <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />QPW FLAPPERS <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: V <br />Date 8-21-2015 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />