My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
11800
>
2300 - Underground Storage Tank Program
>
PR0231589
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2021 3:00:28 PM
Creation date
11/5/2018 12:51:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231589
PE
2381
FACILITY_ID
FA0010414
FACILITY_NAME
UPS Lathrop Hub
STREET_NUMBER
11800
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
02
SITE_LOCATION
11800 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\11800\PR0231589\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/9/2013 8:00:00 AM
QuestysRecordID
159076
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CAUFORTMA c� <br /> i STATE'NATER RESOURCES CONTROL BOARD t 7 1,„ �'; <br /> v/ UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B �s <br /> COMPLETE A SEPARATE FORM FOR CH TANK SYSTEM. .. .y. o <br /> MARK ONLY ❑ I NEW PERMIT S RENEWAL PERMIT ❑ 7 PER,"E '- <br /> ❑ S CHANGE OF INFORMATION CLO _ SIT.- <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ a AMENDED PERMIT ❑ 5 TEMPORARY TANK CLOSURE CDB TANK RE VE •� <br /> OSA OR FACILITY NAME WHERE TANK IS INSTALLED: I IU <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY A UNKNOWN <br /> A. OWNEWS TANK L 0.s 1-- <br /> ! a. MANUFACTURED BY: s 61Z <br /> 4 DATE INSTALLED(M AYNEA)1) I I 0. TANK CAPACITY N GALLONS: <br /> If.TANK CO NTS IFA IISMARKED.CCMPLET9ITEMC. <br /> A. MOTOR VEHICLE FUEL ❑ a O0. g, I C ❑ Ia REGULAR S DIESEL 'f/ <br /> UNLE40ED ❑ e AVUTCN GAS <br /> 2 PETROLEUM ❑ 90 ENPTV 1 PRCOIJCT ❑ 1D PREMRUM a GT_UEL ❑ ] .METHANOL <br /> ❑ 7 CHEMICALPROCUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 UNLEADED Q 5 JET FUEL <br /> ❑ 94 OTHER (DESCRIBE W ITEM 0. BELOYq <br /> 0. 6(A.11 IS NOT MARKED. ENTER NAME OF SUBSTANCE STOPED <br /> C.A.S.s: <br /> III. TANK CONSTRUCTION MARK ONE REM ONLY N BOXES A.3.ANOCW AND ALLTHATAPPUES IN BOX <br /> A. TYPE OF ❑ I DOUBLE WALL ❑ 2 SINGLE WALL WITH EXTERK)R LINER <br /> ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ A SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ I BARE STEEL ❑ 2 STAINLESS STEEL ❑ 2 FIBERGLASS ❑ A STEELCLAO 'Ni FIBERGLASS REINFORCED PLASTIC <br /> MAT ERIAL ❑ 5 CONCRETE ❑ S POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ S 100Y• METHANOL COMPATBLE WIFRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ <br /> C INTERIOR <br /> 2 EPDXY LINING A PHENOLC LINING <br /> ❑ 5 MAW LINING C:] e UNLINED ❑ 95 UNKNOWN ❑ <br /> ❑ 9D OTHER <br /> IS LNNG MATERIAL COMPATIBLE WITH 100% METHANOL? YES—D. <br /> ED.CORROSION ❑ 1 POLYETHYLEENE WRAP [:] 2 COATING ❑ 0 'AMYL WRAP ❑ a FIBERGLASS REINFORCED PIASTC <br /> PROTECTION ❑ S CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ N OTHER <br /> I .PIPING INFORMATION CIRCLE A FABOVEGROUNOOR U FUNCERGROUND.30THIFAPPLICAeLE <br /> A. SYSTEM TYPE A u I SUCTION A U 2 PRESSURE A U 2 GRAVITY A U 99 OTHER <br /> I\ B. CONSTRUCTION A U I SINGLE WALL A U 2 DOUBLE WALL A U S LINED TRENCH A U 95 UNK40WN A U N OTHER <br /> n\\ C. MATERIAL AND A U I BARE STEEL A U 2 STAINLESS STEEL A U 2 POLYVINYL CHLORIDE(PVC(A U a FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U S CONCRETE A U 7 STEELWW COATWG A U 3 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 2 GALVANIMO STEEL A U 10 CATHCOICPROTECTICN A U 95 UNKNOWN A U 99 OTHER <br /> 0. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ O AYCROWRWO ML [790 OTHER <br /> N <br /> V.TANK LEAK DETECTION <br /> 1, ❑ 1 VISUAL CHECK ❑ 2 INVENTORY REOONC2.uTKON ❑ 2 VAPOR MONITORING❑ a AUTOMATIC TANK GAUGWG ❑ S GROUND WATER MCNITCRNG <br /> ❑ 5 TANK TESTING ❑ 7 NTERSTRIALMONRORNG ❑ 91 NONE ❑ 95 UNMIOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MOIDAYNR) 2ESTIMATEO CUANTITY OF 2.WAS TANKFILLEO WITH <br /> SUBSTANCc'REMAINING GALLONS WERT MATERIAL] YES ❑ NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO ME BEST OF MY KNOWLEDGE, IS TRUE ANO CORRECT <br /> APPLICANTS NAME <br /> DATE <br /> LOCAL AGENCY USE ONLY THE STATE LD.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW-�75 <br /> STATE I.D. <br /> COUNTY 9 JURISDICTION t FACILITY 9 TANK 2 <br /> PERMIT NUMBER LIZA-II PERMIT APPROVED BYIOATE PERMIT EXPPII—RAATION�CATE1�� <br /> FORM B *M THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> Fanamlapa <br /> v <br />
The URL can be used to link to this page
Your browser does not support the video tag.