My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
2300 - Underground Storage Tank Program
>
PR0231585
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2021 5:00:29 PM
Creation date
11/5/2018 12:53:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231585
PE
2361
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
01
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HARLAN\15600\PR0231585\BILLING 2010 - 2015.PDF
QuestysFileName
BILLING 2010 - 2015
QuestysRecordDate
12/19/2017 11:13:22 PM
QuestysRecordID
3699814
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0 o. e, <br /> STATE OF CALIFORNIA `^^`� ,�* <br /> STATE WATER RESOURCES CONTROL BOARD D <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B ""� <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. �"�^�""�^ o <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ T PERMANENTLY CLO ED ON E <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED l`fJ <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.p B. MANUFACTURED BY: U� <br /> C. DATE INSTALLED(MO/DAY/YEAR) 4/ D. TANK CAPACITY IN GALLONS: <br /> IL TANK CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A, 80 MOTOR VEHICLE FUEL OIL B C to REGUAR UNLEADED ❑ 3 DIESEL 0 6 AVIATION GAS <br /> 2 PETROLEUM PRODUCT ❑ 1D PREMIUM UNLEADED ❑ 4 GASAHOL T METHANOL <br /> 3 CHEMICALPRODUCT ❑ 95 UNKNOWN E] 2 WASTE ❑ iD MIDGAAOE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE M REM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEMI® 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> E <br /> B. TANK J i BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ ? ALUMINUM O 8 100% METHANOL COMPATIBLE W/FRP <br /> (PHmary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING E:3-6- UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 10096 METHANOL? YES— NO_ <br /> D.EXTERIOR F-1 1 POLYETHYLENE WRAP F—] 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN 99 OTHER <br /> E.SPILL AND OVERFILL,etc. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO_ STRIKER PLATE YES— NO DISPENSER CONTAINMENT YES_ NO_ <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U,'1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U -1 SINGLE WALL A U 2- DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U T STTEEEELLW/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION AQ,16 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION D 1 MECHMG L LINE IFAI( UNE nGNTNEM O 3 CONNNUWE pRER5TI16LL ❑4 ELECTRONIC LINE O 5 AUTOMAnC NAP F] 99 OTHER <br /> DE =R TESTING MOMTORMG MK DEFECTOR SHUmO" <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK " RECONCILATIONANUAL INVENTORY ❑ 3 VAOZrMONIITORING ❑ 4 GAUGNGIC TANK AUTOMAT ❑ 5 MONTORINGGROUND WATER ❑6 TESTINGTANK <br /> ❑ T MONTORNG INTERSTITIAL ❑ 8 SIR ❑ 9 WEEKLY MANUAL ❑10 MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> TANK GAUGI NG TESTING <br /> VI.TANK CLOSURE``INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE LAST U404MO/DAYNR) 2.ESTIMATED QUANTITY OF (� 3.WAS TANK FILLED WITH ❑ ❑ <br /> /:J SUBSTANCE REMAINING GALLONS INERT MATERIAL? YES NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRINTED 6 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# i <br /> STATE LD:# m = <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLI ON-FORM A,UNLESS A CURRENT FORMA HAS BEEN FILED. FO�1 C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THFWRGROUND STORAGE TANK REGULATIONS <br /> FORME (6-95) t./ to /yj 77,s <br />