@CONSTRUCTION. KEY NOTES:
<br /> ------ - - 1 REMDVE AND DISPOSE OF EXISTING CONCRETE SLAB, UNDERGROUND }
<br /> -------�� — O PRODUCT TORAGE TANKS (1-10,000 & 1-12,000) RODUCT PIPING, m
<br /> VAP
<br /> AND ELECTRICAL CONDUITS " Q RE EXISTING
<br /> �
<br /> 4TAN __ UIRED FDR-NEW TANK INSTA MR SEE SHE._EJS
<br /> —_
<br /> PT=5,AND PT-6 -.. _ a '..
<br /> 2 REMOVE AND DISPOSE OF EXISTING CONCRETE DRIVE SLAB, PRODUCT
<br /> AND VAPOR RECOVERY PIPING,
<br /> OREMOVE (2) EXISTING PRODUCT DISPENSERS AND TECH 21 CARD
<br /> READER AND STORE ON SITE FOR RELOCATION AND INSTALLATION. N
<br /> OREMOVE AND DISPOSE OF EXISTING CONCRETE DISPENSER ISLANDS 0
<br /> AND STEEL GUARD POSTS, TYPICAL OF 2 ISLANDS AND 4 GUARD
<br /> POSTS, EXTEND EXISTING CARD READER CONDUIT AND CONDUCTORS w
<br /> TO NEW CARD READER LOCATION. REINSTALL TECH 21 CARD READER,
<br /> OINSTALL TWO (2) NEW 15,000 GALLON, DOUBLE WALL, UNDERGROUND, w
<br /> PRODUCT STORAGE TANKS, SEE SHEETS PT-3 AND PT-4.
<br /> OEXTEND EXISTING CONDUITS AND CONDUCTORS TO NEW TURBINE
<br /> LOCATION AND CONNECT TO EXISTING CIRCUITS.
<br /> OINSTALL NEW DOUBLE WALL, FIBERGLASS, PRODUCT AND SINGLE
<br /> WALL, FIBERGLASS, VAPOR RECOVERY PIPING FROM NEW STORAGE
<br /> TANKS TO NEW DISPENSERS. SEE SHEETS PT-5.
<br /> OINSTALL NEW. VEEDER-ROOT TLS-350ANK MONITOR'FOR'TURBINE{,)
<br /> SENSORS AND CONNECT TO EXISTING ECTRICAL PANEL AS Z
<br /> .REQUIRED TANK SYSTEM SHALL BE .WIjD FOR POSITIVE SHUTDOWN,.(
<br /> VERIFY LOCA1)'OITH COUNTY REPRESENTATIVE, " a
<br /> ORELOCATE AND REINSTALL TWO (2) EXISTING PRODUCT DISPENSERS a
<br /> AND ONE (1) SATELLITE DISPENSER ON NEW ENVIRON DISPENSER v
<br /> CONTAINMENT BOX (TYPICAL OF 3). EXTEND EXISTING CONDUITS AND x 0.
<br /> CONDUCTORS FROM EXISTING DISPENSER LOCATION TO NEW R v ;
<br /> LOCATION. INSTALL NEW 3/4' CONDUIT FOR DISPENSER CONTAINMENT
<br /> MONITORING. EXTEND FROM PRODUCT DISPENSERS TO THE TANK co o
<br /> MONITOR LOCATION, v ao N N
<br /> O w II a
<br /> INSTALL NEWSINGLE WALE,- F(BE,RGCASS VENT. LINES -}ROM NEW
<br /> U`�t'Oj
<br /> 10 TANKS 70 EXISTING VENT RISERS, N o w to
<br /> LM L
<br /> INSTALL NEW TANK GAUGE AND CONNECT TO NEW MONITOR SYSTEM, coo c°p� a
<br /> 11 TYPICAL OF 2, 0000 00 0)
<br /> 12 INSTALL NEW HYDROSTATIC ANNULAR SPACE PROBE AND CONNECT TO U
<br /> NEW MONITOR SYSTEM, TYPICAL OF 2. Z
<br /> 13 INSTALL NEW 4'-0' x 20'-0', STEEL FORMED, CONCRETE DISPENSER
<br /> ISLAND (TYPICAL OF 2). SEE SHEET PT-8, W
<br /> 14 INSTALL NEW BUMPER GUARDS (TYPICAL OF 4). SEE SHEET PT-8. Q
<br /> OINSTALL NEW 8' THICK CONCRETE TANK SLAB WITH g4 18' O.C., ■ U �,
<br /> 15 EACH WAY, PATCH AND REPAIR A.C. PAVING AS REQUIRED TO MATCH
<br /> EXISTING. V)
<br /> 1fi INSTALL NEW 6' THICK CONCRETE DRIVE SLAB WITH q4 REBAR AT Q N
<br /> 18' D,C. EACH WAY, PATCH AND REPAIR A.C. PAVING AS REQUIRED y
<br /> 17 INSTALL NEW 25'-0' x 45'-0' CANOPY. SEE CANOPY DRAWINGS,
<br /> �J U
<br /> SHEETS CS-1 AND CS-2, CONNECT NEW CANOPY LIGHTING TO H„ 4T
<br /> _ EXISTING CIRCUITS AS REQUIRED. a
<br /> 18 INSTALL NEW A.C. PAVING AT NEW CONCRETE EDGES AND IN AREAS IQ-
<br /> DAMAGED BY NEW CONSTRUCTION AS REQUIRED TO MATCH EXISTING,
<br /> FEATHER INTO EXISTING A.C. PAVING.
<br /> i" DIESEL SATELLITE
<br /> 10 DISPENSER
<br /> 3
<br /> 12 Z
<br /> - e 3 f1
<br /> ` t5 _1LGENERAL NOTES: g oN w
<br /> - - — — - r U
<br /> CL
<br /> 'DIESEL TANK 7 a 2 16 ALL CONSTRUCTION IS EXISTING AND TO REMAIN UNLESS NOTED OTHER- ) W 1
<br /> 78 14 17. } Z .z n' Z
<br /> 9 ALL WORK SHALL COMPLY HATH ALL APPLICABLE CODES AND REGULA- W x LLL
<br /> ELECTRICAL INSTALLATION SHALL COMPLY WITH 1993 N.E.C. ARTICLE V L) U' ,0
<br /> --- - --
<br /> 514 FOR GASOLINE DISPENSING STATIONS. 0 < Z Z N Z
<br /> O o o CONTRACTOR IS TO PATCH AND REPAIR ANY EXISTING IMPROVEMENTS w Y �" _F?
<br /> 13 DAMAGED BY NEW WORK AS REQUIRED TO MATCH EXISTING CONDITIONS. W Z (� d :rjo
<br /> GASOLINE TANK10 16 INSTALL EXPANSION JOINTS (EJ) AND CONTROL JOINTS (CJ) IN ALL NEW w V) �()
<br /> CONCRETE AS INDICATED ON PLAN. a a Z •-
<br /> ENVIRONMENTAL HEALTH DIVISION UNDERGROUND 'WRING SHALL BE INSTALLED IN THREADED RIGID METAL Z
<br /> EXISTING EMERGENCY 304 E,Weber Ave.Third Floor CONDUIT PER NEC 514-8. FOR UNDERGROUND CONDUIT, BURIED A MIN- a
<br /> SHUT-OFF SWITCH H O. Box 388,Stockton CA 95201-0388 IMUM OF 24 INCHES BELOW GRADE, SCHEDULE 40 PVC MAY BE USED
<br /> Approved 9 HATH RIGID METAL CONDUIT RISERS AND EQUIPMENT GROUNDING CON-
<br /> Denied DUCTORS IN ACCORDANCE WITH NEC 514.8. EXCEPTON NO, 2
<br /> Conditio s l n ✓ (/rtitF>/ N
<br /> EXISTING ELECTRICAL v� Ct�ri w4K-ir INSTALL EXPLOSION PROOF SEALS AT ALL ENDS OF ALL CONTROL, SIO-
<br /> PANEL LOCATION 8 C � NAL AND POWER WIRING CONDU17S BETWEEN DISPENSER ISLANDS AND
<br /> Oeste �h-4-Y by WIRING GUTTER IN BUILDING PER NEC 514-6 (a) AND (b). ALL CON-
<br /> :OUITS WITHIN A 20 FOOT RADIUS OF FUEL DISPENSERS SHALL BE
<br /> �tn �iLX�s4.ieS D _ SEALED PER NEC 511-5 AND 501-5. U
<br /> ^.CIRCUIT DISCONNECTS TO OR THROUGH THE DISPENSING PUMP SHALL Z
<br /> DISCONNECT ALL CONDUCTORS, INCLUDING ANY GROUNDED CONDUCTORS :1
<br /> PER NEC 514-5. F U 4 �
<br /> m V) m 1 I �- N
<br /> 1';.J `IIW')U,"I jj"f/ v yYj/7�CPiUNAUTHORIZED CHANGES AND USES: The engineer preparing these Y N °c3 M
<br /> tn L / plans will not be responsible for, or liable for unauthorized u) (L
<br /> for, unauthorized changes to or uses of these plans. All changes to GI
<br /> plans must be in writing and must bne approved by the preporer
<br /> Y, (s"(.eP�n�'� Z� LLL 0y of these plans.
<br /> CL �(p 3 (y C ) i t{ q_µV{ Sc ° t $ /t)� v Construction contractor agrees that to accordance with generally
<br /> 1 aacepted construction practices, construction contractor will be
<br /> �Cri41iN.L(LC.C��/ 'r 7Z.E2�Q/ G? d required to assume sole and complete responsibilty for job site
<br /> —}; Conditions during the course of construction of this project, w O
<br /> . .�,r o�[¢ 'j �y including safety of all persons and property, that this requirement Y Z Z Z
<br /> 1"�" __ f_ i,t,i oo_. . .;yv ° /� U shall be made to apply continLously and not limited to normal U
<br /> AI [-Gfv�✓`� ��jj working hours, and constructlon contractor further agrees to CC ¢ _ ¢ W
<br /> ��,{9y) CT/1- EOvUXrlLyLiZ(L. defend, Idemnify and hold design professional harmless from any O 0 U 0 tK 0 G 5
<br /> ` Q �n-s-i ,LLL and all liability, real or alleged. In connection with the performance
<br /> S fQarr, G�1 "�(Ai� C�'w>��" of work on thio project, excepting liability arising from sols SEAL:
<br /> f_ 1.�,T,.rrN • negligence of design professional.
<br /> (may Engineers Note fo Contractor:
<br /> YF2(9ja—1 l) at�n �- � Y1tJ The existence and location of any underground utilities, pipes,
<br /> q and/or structures shown on these plans were obtained by a
<br /> (�li �� &,lt_a_ems search of avallable records. To the best of our knowledge, there
<br /> `' �(ri[7N✓ A �.®� are no existing utilities except as shown on these plans. The
<br /> contractor shall ascertain the true vertical and horizontal location
<br /> and site of those to be used of any underground utilities and
<br /> shall be responsible for any damage to any public or private
<br /> t 2� Lp�. j y�1/,_P9'(-(�Ql `T11L0�✓LI�I �'L -a-(�'�'-""
<br /> utilities, shown or not shown hereon.
<br /> O-C'FI Va, 4.6, IMPORTANT NOTICE
<br /> D �v C.��' G�> �(QCK + Section 4210/4217 of the Gowamment Code requires SHEET N0:
<br /> cryry L(�'i(- a Dfaa Alert Identig<otyn Number a Issued before a
<br /> / Permit to FColl wll be wild FQor your Dig Alert
<br /> , Lw ID Number Cull
<br /> W H-p CA UNDERGROUND SERVICE ALERT PT - 2 ,
<br /> �� )1,1�J-ttiWf
<br /> avlq - yt a `�, C_c' t1-800-424-5555 SHEET 2 OF -
<br /> For Underground. Locatsg. 2 workMg daysbefore you dig. NIPPON
<br /> SCALE: 1' 20`-0„