My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County AWNBED <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468 3420 Fax:(209)468-3433 Web.vvww.siQov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> FedEx Ground-Tracy (209)839-2000 September 18, 2017 <br /> Facility Address: CERS ID: <br /> 5655 Hood Way,Tracy, CA 95377 ERS ID: <br /> Inspection Contacti Title: <br /> Phone: <br /> Kevin McTee Facility Maintenance Mg (209)830-5256 <br /> Inspection Type: Program: <br /> INSPECTION/REINSPECTION 1 hr minimum 2351 -UST FACILITY-2481 COMPLIANT <br /> Consent For. Consent Glven By: <br /> El Inspection El Photos O Samples Kevin=, Facility Maintenance Mgr <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Elmer Mortera 01/04/2018 <br /> Service Technician Manufacturers Training: <br /> Veeder Root, 01/03/18;VMI, 03/09/19 <br /> CCR=California Code of Regulations HSC=Health and Safely Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate 'v OR o COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system OV o R o COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted o V OR o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current OV o R o COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan .V OR o COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan o V o R o COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed mV .R o COS <br /> 108 CCR 26370,2638(e) Failed to notify the EHD 48 hours priorto conducting testing o V o R o COS <br /> 109 CCR 2637 Failed to test secondary containment o V OR o COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V OR o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually o V o R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V OR o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days OV o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down o V o R a COS <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days u V OR o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification mV o R o COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V Or R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests 'v OR in COS <br /> 119 HSC 25299 Documents were falsified or misrepresented o V OR o COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V OR o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V OR c COS <br /> 122 1 CCR 2631 G) Failure to submit UST system component statement of compatibility for substance stored 'v o R o COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions o V o R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records an site for at least 6 1/2 years o V o R o COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site o V o R o COS <br /> FA0023065 PRO540345 SC333 09/115/2017 <br /> EHD 23-01 Rev.09/72/16 Pagel of 6 Underground Storage Tank Program OIR <br /> 9171 9690 0935 0152 1406 51 <br />
The URL can be used to link to this page
Your browser does not support the video tag.