COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form:Addendum for Vacuum/Pressure Interstitial Sensors LG 163-1,Enc.11 <br /> L Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of <br /> this form must be included with the Monitoring System Certification Form,which must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Manufacturer:Veeder-Root Model:330020-464 System Type:F Pressure r4o Vacuum <br /> Sensor ID <br /> S1 Component(s)Monitored by this Sensor: Diesel 1 product line <br /> Sensor Functionality Test Result:P Pass r Fail Interstitial Communication Test Result: 'Pass I Fail <br /> S2 Component(s)Monitored by this Sensor: Diesel 2 product&transition <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: OO:Pass r Fail <br /> S3 Component(s)Monitored by this Sensor: Vents <br /> Sensor Functionality Test Result:P Pass r Fail Interstitial Communication Test Result: :Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result:r Pass r Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: :. ,Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: .a Pass Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result:r Pass r Fail Interstitial Communication Test Result: ., Pass I Fail <br /> ow was interstitial communication verified? <br /> P,Leak Introduced at Far End of Interstitial Space' Gau e Visual Ins ection Other Describe in Sec.J,below <br /> Vacuum was restored to operating levels in all interstitial spaces: Yes r No(If no,describe in Sec.J, below) <br /> J.Comments 500 characters max.use additional sheets if needed): <br /> Page 3 of 3 <br /> 1 If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br /> WO: 2328941 <br />
The URL can be used to link to this page
Your browser does not support the video tag.