My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:44:41 PM
Creation date
11/5/2018 1:13:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\H\HOOD\5655\PR0540345\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sicov.orD/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FedEx Ground-Tracy 5655 Hood Way, Tracy September 08, 2017 <br /> UST System Observations <br /> 322 HSC 25281 6(a) Unburied below grade emergency generator system failed to meet exemption status 'c V R s:COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status n V o R u COS <br /> 324 CCR 2717.1(9) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(1) Deposited petroleum into a red tagged UST o V in R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V n R o COS <br /> 327 CCR 2631 A UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements o V o R o COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V o R o COS <br /> 330 CCR 26360(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V u R c COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0,1 gph line test for conventional suction piping not performed(pre-January 1984) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) n V o R n COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R -COS <br /> 2030 See below Unlisted Operations/Maintenance violation u V c R o COS <br /> 2060 See below Unlisted Design/Construction violation o V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C)Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted.The legend was not clear for identifying the locations <br /> where monitoring will be performed. Immediately log into the California Environmental Reporting System(CERS)at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a repeat violation,Class II. <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br /> Annual monitoring system certification and leak detector testing were last performed on 8/17/2016 and was due by <br /> August 2017. Testing has not been completed and is past due. These tests are required once every 12 months. <br /> Immediately schedule these tests and provide 48 hours notification to the EHD. Please be aware that a follow up <br /> inspection will be charged at our current hourly rate. <br /> This is a Class II violation. <br /> FA0023065 PR05 15 SC001 09/0812017 <br /> EHD 23-01 Re,09/22/16 Page 3 of 8 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.