My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2300 - Underground Storage Tank Program
>
PR0231636
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2021 12:44:32 PM
Creation date
11/5/2018 2:59:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231636
PE
2381
FACILITY_ID
FA0003869
FACILITY_NAME
DEUEL VOCATIONAL INSTITUTION*
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23912001
CURRENT_STATUS
02
SITE_LOCATION
23500 KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KASSON\23500\PR0231636\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
6/18/2013 8:00:00 AM
QuestysRecordID
175842
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI/ WATER RESOURCES CONTRO `OARD <br /> FORM `B': UNDEIrGROUND STORAGE TANK PROMAM ' <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. __ z <br /> 10 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 05 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 2 <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: YEb-oa rAesto FARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY 4 <br /> A. OWNERS TANK ID# I B. MANUFACTURED BY: IJ < W <br /> O YEAR INSTALLED I T D. TANK CAPACITY IN GALLONS: 2 <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ETROLEUM B. C. E] 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑3 CHEMICAL PRODU4 O CT PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL [-] 6 AVIATION GAS <br /> ❑5 HAZARDOUS 80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE ❑7 METHANOL K99 OTHER(DESCRIBE IN REM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.kolL C.A.S.a: 0 -Z- <br /> Ill. <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 02 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> S.TANK <br /> MATERIAL F-15 CONCRETE ❑6 POLYVINYLCHLORIDE [--17 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑10 GALVANIZED STEEL 2<95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED [:]2 ALKYD LINING F-13 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ,®95 UNKNOWN <br /> ❑ISUNING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ i POLYETHLENE WRAP ❑2TAR OR ASPHALT ❑3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PUAnC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE 95UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELARON A U 2 STAINLESSSTEEL A U 3 POLYVINYLCHLORIOE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD yyppyy/�FRP r A U B[�p% pETHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A O99 OTHER 9i rl' � ^yo`f <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 5 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID R TANK ID B <br /> b (0 111 =(0 d0 ID 7- <br /> CU ENT LOCAL AGENCY FACILITY ID p APPROVED BY IEPL PHONE#WITH AREA CODE <br /> 1-94 <br /> PERMIT NUMBER PERMIT APPROVAL DATE P R IT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: - <br /> FORM B(6-29-66) THIS FORM MUST BE ACCOMPAN4u BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESMftiJARENT FORMA' HAS BEEN FILED <br />