My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL_1989
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2300 - Underground Storage Tank Program
>
PR0231636
>
REMOVAL_1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2021 1:29:50 PM
Creation date
11/5/2018 2:59:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1989
RECORD_ID
PR0231636
PE
2381
FACILITY_ID
FA0003869
FACILITY_NAME
DEUEL VOCATIONAL INSTITUTION*
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23912001
CURRENT_STATUS
02
SITE_LOCATION
23500 KASSON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KASSON\23500\PR0231636\REMOVAL 1989.PDF
QuestysFileName
REMOVAL 1989
QuestysRecordDate
6/18/2013 8:00:00 AM
QuestysRecordID
175715
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'> * Tanks shall be purged of flammable vapor in <br />accordance with NFPA guidelines. It shall <br />be the North Cal Construction's responsibility <br />to demonstrate to the fire inspector, upon <br />arrival, that the vapor concentration inside the <br />tank is not more than 108 of the lower explosive <br />limit (L.E.L.) of the product previously in the <br />tank. Atmosphere inside the tank shall be checked <br />at the top and the bottom. An oxygen measuring <br />device may also be used to ensure that the tank <br />has been inerted. An oxygen reading of below <br />138 will be required prior to removal <br />* It is necessary that the vapors be purged prior <br />to arrival of the firensipector_ Each tank <br />will be allotted a maximum of 1 hour for <br />removal and loadings for transport. <br />* Openings are to be closed using a pressure - <br />vacuum relief device or other NFPA approved <br />device. <br />* Tanks are to be lifted using proper equipment. <br />It will be the fire inspector's responsibility <br />to stop any operation the inspector believes <br />to be unsafe. Tanks shall not be dragged at <br />any time. Only nonsparking tools may be used <br />to clean exterior of tank. <br />* Immediately transport tanks from site to an <br />
The URL can be used to link to this page
Your browser does not support the video tag.