COMPLIANCE INFO_2002 UST PIPING
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2002 UST PIPING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 1:35:05 PM
Creation date
11/5/2018 3:21:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 UST PIPING
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\J\JOE POMBO\2430\PR0506796\UST PIPING 2002.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(OPENINGS IN SLAB TO HAVE 1 -1/2" CROWN) <br /> 26.-8" t <br /> 18" 5'-2" 13'-4" 5'-2" 18 <br /> —1� 4 k1k <br /> AALL MANHOLE ACCESS COVERS 14 15 16 <br /> 3'- SPA�tAR TO BELOW GRADE SHALL BE <br /> TK3-5 <br /> P. <br /> ) MONITORLIQUID TIGHT AND LOCKABLE <br /> (TOP.) 4 <br /> P 00 !r A.C. PAVING <br /> tO \ 6" CONCRETE TANK SLAB <br /> �FyvA1_1 2 W/ 6X6/#4/4 WWM <br /> TYP ALL) 12 18" (ryp/ALL 18" 18" <br /> TYP. ) (TYP. TYP. C PAVING d. o O <br /> A. . <br /> m I � •C <br /> to <br /> , . .9 •. s _ <br /> ,O 4 P. �A. �;• L � ..P .4 Y . P P4 .9 . 4• U •`�` <br /> • 4 .• • .P • • ' P .Y • .� e • w / <br /> m 48" DIA. TURBINE AND 3" MIN. '� <br /> ^ "p VENT/ STAGE II VAPOR �'?I'= N o yam- O <br /> RECOVERY SUMP (TYP.) � <br /> i� -- AROUND ALLBOTTOM <br /> PENETRATIONS (TYP.) m •Qr1 <br /> 0 m + L <br /> +I <br /> o _y <br /> 42";r 2p 42" DIA. FILL & VAPOR 3 <br /> n VAPOR RECOVERY SUMP NOTE: o L <br /> TK3-5 (ryp,) ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A,1-1/2" CROWN OF CONCRETE -�� o Q V <br /> o TO PREVENT WATER INTRUSION INTO THE MANHOLE. THE OWNER'S ENGINEER WILL BE REQUIRED cc <br /> TO SIGN OFF ON THIS ITEM ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL BE N p G O <br /> id B PAID. CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF tD <br /> a THIS DESIGN REQUIREMENT IS NOT MET. O O <br /> QQNTRDL Typical Slab at Tanks N <br /> M EXPANSION <br /> JOINTS TO BE A <br /> "TOOLED" WITHO <br /> 3/8" RADIUS NOT TO SCALE: lT <br /> 93— <br /> 48" DIA. TURBINE AND Tank Slab Concrete Specifications mVENU <br /> j STAGE 11 <br /> REC VERY SUMPVAPO(TYP.) <br /> r 1. UNLESS OTHERWISE NOTED ON THESE DRAWINGS: 4. REINFORCING STEEL FOR TANK SLABS SHALL BE 6 x 6 - 4/4 WWM WELDED WIRE FABRIC I <br /> 6" x 6"-4/4 WWM a. CONCRETE - REGULAR WEIGHT HARD ROCK CONCRETE (150 LBS/CU FT) OR #3 BARS ® 16 O.C. EACH WAY. SUMP CAGES SHALL BE #3 REBAR TOP AND BOTTOM. CC <br /> (OR #3 ® 16 O.C.) b. CEMENT - TYPE II, SULFATE RESISTANT 5. MAINTAIN CONCRETE IN A MOIST CONDITION FOR AT LEAST 7 DAYS AFTER PLACEMENT. <br /> c. AGGREGATES - ASTM C33, (MAXIMUM SIZE 3/4 INCHES) <br /> 1'-0" CHAMFER d. 28 DAY CONCRETE STRENGTH (Pc): 6. PLACE CONCRETE DIRECTLY FROM TRUCK INTO FORMS. DO NOT PUMP CONCRETE UNLESS AA�� <br /> (TYP.) 2,500 PSI - SLAB (DESIGN BASED ON 2,000 PSI NO SPECIAL INSPECTION REQUIRED) SPECIAL INSPECTION, IN ACCORDANCE WITH CHAPTER 3 OF THE UBC, IS PROVIDED. V/ Q_ <br /> A I3 REBAR CAGE TOP & e. SLUMP - 3"± 1" - 4" MAXIMUM AT POINT OF PLACEMENT 7. SUBMIT MIX DESIGNS, WITH STRENGTH AND SHRINKAGE TEST RESULTS, TO OWNER'S ENGINEER <br /> OTTOM 2" COVER TYP. f. SHRINKAGE - 0.05% MAXIMUM AT LEAST 7 DAYS BEFORE PLACING CONCRETE. L D <br /> CONCRETE SLAB DESIGN - 2,500 P.S.I. ® 28 DAYS TK3-5 ALL AROUND PENETRATIONS f. ENTRAINED AIR RANGE - 2% TO 4% A� <br /> • 2. CONCRETE SLAB THICKNESS SHALL BE A MINIMUM OF 6.0 INCHES 8. CONSOLIDATE CONCRETE IN PLACE USING A MECHANICAL VIBRATOR. W <br /> Ty p i c a I Tank Slab Reinforcing (UNLESS OTHERWISE NOTED ON THESE DRAWINGS) 9. BEFORE PLACING CONCRETE, SECURE REINFORCING STEEL, ANCHOR BOLTS, DOWELS, AND V <br /> 1 8 A 3. CONCRETE SHALL BE NORMAL WEIGHT WITH A MIX OF 1 2 1/2 3 1/2, WITH A MAXIMUM OTHER INSERTS IN POSITION TO PREVENT MOVEMENT. <br /> 7 1/2 GALLONS OF WATER PER SACK. 10. MATERIALS AND WORKMANSHIP SHALL CONFORM TO A.C.I. - 318 (SPECIFICATIONS OF THE <br /> NOT TO SCALE: DESIGN AND PLACEMENT OF CONCRETE). /AA1 <br /> W � <br /> L <br /> v� M <br /> � C <br /> IL V <br /> _J F- <br /> _ C <br /> t` m <br /> 0 .� <br /> 0 O C;6 <br /> N- <br /> m j to <br /> N � N <br /> 40 <br /> U <br /> 0') C <br /> Tait&Associates.bm <br /> er..ti ' Aldfi sw . a.P+•e <br /> asfaba m <br /> T 11Lraw••.ae• <br /> 80rA�oax9r92Ae <br /> 0"Ge"M <br /> TrM4ee082UNK <br /> e•WAA� <br /> s.r . ey99.4arP. <br /> 0X&^a <br /> i fc: eNKQ-T • <br /> �;hr c�.r u9.wP�9PPx•RrwMl <br /> `.. .�Na. 014785`I Is•"00•1"10 <br /> ;< EXP. 3-31-2c0 F, consultant job# <br /> AR1596 <br /> master release date <br /> NO, BP WEST COAST PRODUCTS MASTER REVISIONS project master <br /> exe date drawn by <br /> NO. DATE REVISIONS BY PROJECT RELEASE <br /> Fllename <br /> PERMIT fac06347 tk -5 12-02 <br /> Facility Project <br /> BID 6347 <br /> CONST. sheet name <br /> AS-BUILT T K3 -5 <br />