My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1997 PLAN
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
INSTALL_1997 PLAN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2021 3:48:04 PM
Creation date
11/5/2018 3:38:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1997 PLAN
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (MOBIL) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\401\PR0231346\INSTALL PLAN 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> LIGHTING FIXTURE NOTES LIGHTING FIXTURE SCHEDULE LIGHTING PLAN KEY NOTES <br /> 1. ALL FIXTURES SHALL BE APPROVED BY U.L. FIXTURE LAMPS MOUNTING El EXISTING 2'x4' RECESS FLUORESCENT TROFFER TO REMAIN. CONTRACTOR TO CLEAN <br /> DESCRIPTIONS AND LENS AND REPLACE ANY BURNED—OUT LAMPS. <br /> 2. ALL H.I.D. AND FLUORESCENT FIXTURES SHOULD USE HIGH POWER FACTOR BALLASTS. Om w o w o v WATTS Y w VARIATIONS <br /> 3. CONTRACTOR TO PROVIDE ALL HARDWARES, BRACKETS, LAMPS, TUBES, ...ETC. FOR A >_ z a o U s o m AND " z U J <br /> COMPLETE INSTALLATION. z _ .� z NPE 9 cw. W 3 <br /> 4. ALL LIGHTING FIXTURES SHALL BE PERMANENTLY ATTACHED TO THE CEILING PER N.E.C. <br /> 410-16(C). F1X 120 3 32W, F32T8 X 2'x4' TROFFER WITH PRISMATIC LENS. <br /> 2900 LUMEN LITHONIA #2SPG340—Al2-120GEB WITH <br /> 5. CONTRACTOR TO INSTALL ALL LIGHT FIXTURES INCLUDING OWNER—PROVIDED FIXTURES. 3500K ELECTRONIC BALLAST OR APPROVED EQUAL. <br /> 6. SHATTER SHIELDS FOR ALL LIGHTS ABOVE FOOD PREPARATION, WORK, AND STORAGE LIGHTING MANDATORY MEASURES LIGHTING TITLE-24 COMPLIANCE <br /> AREAS WILL BE PROVIDED. <br /> CERTIFICATE OF COMPLIANCE - LIGHTING LTO-1 <br /> LIGHTING FIXTURE SUPPORT DETAIL PROJECT NAME DATE <br /> ULTRAMAR — LODI 7-30-97 <br /> REFERENCE IN PR JECT ADDRESS <br /> CONSTRUCTION 401W. KETTLEMAN LN. & SOUTH LEE AVE. <br /> DOCUMENTS INIAL DESIONER—LIGHTING <br /> ROY M. LEE, P.E. (714) 851-3185 <br /> 9 GAGE WIRE DOCUMENTATION AUTHOR ^ M m. <br /> CEILING SUPPORT SOUTHWEST GROUP <br /> SUSPENSION INSTALLED (714) 851-3185 a�...N. a. <br /> [ ] BUILDING LIGHTING SHUT—OFF BY AUTOMATIC SWITCH . . . . N/A GENERAL kMM#pN <br /> AT EACH CORNER OF DATE OF PLANS 7-30-97 BUILDING CONDITIONED FLOOR AREA 339 SOFT. <br /> EACH FIXTURE. (4 [✓] MANUAL SWITCHING READILY ACCESSIBILE . . . . . . . . . . . E3 BUILDING TYPE NONRESIDENTIAL ❑HIGH RISE RESIDENTIAL ❑HOTEL/MOTEL GUEST ROOM <br /> PER FIXTURE) PHASE OF CONSTRUCTION NEW CONSTRUCTION ❑ADDITION QALTERATION <br /> [✓] ALL AUTOMATIC CONTROL DEVICES SPECIFIED ARE CERTIFIED E3 METHOD OF LIGHTING <br /> COMP ANCE ❑ COMPLETE BUILDING ❑AREA CATEGORY ❑TAILORED PERFORMANCE <br /> [✓] CERTIFIED LUMINARIES/FLUORESCENT BALLASTS . . . . . . . . E3 STAtE111DlT of cOMI"LA x <br /> This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, <br /> Part 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. <br /> TYPICAL RECESSED [✓] INDEPENDENT CONTROL WITH ENCLOSED AREA . . . . . . . . . E3 <br /> 0 O FIXTURE The Principal Lighting Designer hereby certifies that the proposed worksheets, <br /> design represented in this set of any,other <br /> documents is consistent with the other compliance forms and worksheets, with the specifications, and with on other <br /> [✓] UNIFORM REDUCTION OF LIGHTING LOAD TO AT LEAST HALF. E3 calculations submitted with this permit application. The proposed building has been designed to meet the lighting <br /> requirements contained in sections 110, 119, 130 through 132, and 146 or 149. <br /> FIXTURE LOCK <br /> OCCUPANCY SENSORS OR PROGRAMMABLE MEETING CEC Please check one: <br /> CLIP PER NEC CRITERIA MAY SUBSTITUTE . . . . . . . . . . . . . . . . . . . ZI hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this <br /> ARTICLE 410-16 document as the person responsible for its preparotion;and that I am a civil engineer, electrical engineer, or architect. <br /> TYPICAL T BAR (INSTALL 4 PER [ ] SEPARATE SWITCHING OF DAYLIT AREA N/A ❑ I afrimr that I am eligible under the exemption to Division 3 of the Business and Professions Code by Secdon 5534.2 <br /> CEILING FIXTURE) of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I <br /> [ ] SEPARATE SWITCHING OF DISPLAY AND VALANCE LIGHTING IN am a licensed contractor preparing documents for work that I have contracted to perform. <br /> RECESSED FIXTURE (NON—FIRE RATED CEILING) RETAIL AND WHOLESALE STORES . . . . . . . . . . . . . . . . N/A F-1I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by section_ <br /> of the Code to sign this document as the person responsible for its <br /> preparation; and for the following reason:__ <br /> [ ] AUTOMATIC CONTROL OF DISPLAY LIGHTING IN RETAIL AND pRINCPQ ELEC PoCA DESIGNER—NAMENA u N N?, UAIL <br /> WHOLESALE STORES . . . . . . . . . . . . . . . . . . . . . . . N/A ROY M. LEE, P.E. E-074840 7-30-97 <br /> UGIRW tWIMTORI WAWFZ <br /> NEW 400A MAIN ELECTRICAL [ ] TANDEM WIRING OF ONE AND THREE LAMP FLUORESCENT Indicate location on plans of Note Bkuk for Mandatory Measures E-3 <br /> SERVICE SWITCHBOARD "MSB FIXTURES OR/ AND ALL THREE LAMP FLUORESCENT FIXTURES <br /> SERVICE S C 3W, NEMA 3R) WITH ELECTRONIC HIGH—FREQUENCY BALLASTS . . . . . . . . , N/A LIGHTING COMPLIANCE SUMMARY LTG-2 <br /> PROJECT NAME ULTRAMAR — LODI DATE 7-30-97 <br /> Ft PANEL "C' [✓] AUTOMATIC EXTERIOR LIGHTING CIRCUIT CONTROL . . . . . . . . . E2 <br /> 64 PANEL "g' ACAK UGKW POW <br /> (TYP. OF 4) LUMINAIRE NUMBER OF WATTS PER LUMINAIRE CEC DEFAULT TOTAL <br /> NAME DESCRIPTION LUMINAIRES (Including Ballast) Y N+ WATTS <br /> ° Fi 2'x4' RECESS FLUORE. 4 64 0 256 <br /> W/ 2—LAMP (F32T8) ❑❑ <br /> — PANEL El <br /> COOLER J 5C n 5a <br /> i El El <br /> STORAGE J UTILI /OFFICE ❑❑ <br /> I - I ❑ ❑ <br /> 5d ,/� I SUBTOTAL FROM THIS PAGE 256 <br /> 51) V\•/A• PLUS SUBTOTAL FROM CONTINUATION PAGE �0 <br /> (E) (E) (E) LESS CONTROLCREDIT WATTS 0 <br /> J ° (FROM LTG 3) <br /> 5 I ADJUSTED ACTUAL WATTS 256 <br /> IRE TR00 * If not using the CEC Default value, please provide supporting documentation. <br /> ALLOWED LIGHTING POWER (See Performance Compliance Report) <br /> SALES i ARG GTEGM MEW <br /> WATTS <br /> I CASHIER AREA CATEGORY (From Table 2-53N) PER SIF Aw0 0 <br /> (E) (E) (E) 1 (TYP. OF <br /> 6 ) I STORAGE, UTILITY, RESTROOM 0.8 339 271 <br /> ® SALES AREA <br /> 339 271 <br /> TOTALS AREA WATTS <br /> L - -- ° J <br /> REVISIONS <br /> SOUTHWEST GROUP NO. DATE BY COMMENTS Ultramar <br /> SEngineering Consulting Services DB 97 S.T. ISSUED FOR BID <br /> 525 WEST THIRD STREET, HANFORD. CALIFORNIA 93230 <br /> 1720 E. Garry Ave. a Suite 232 a Santa Ana a CA 92705 <br /> Tel (714) 851-3185 e Fax (714) 851-3016 <br /> ELECTRICAL LIGHTING PLANQgOFESSpR.M.L. <br /> DESIGNED: ELECTRICAL LIGHTING PLAN <br /> yq <br /> SCALE: 1/4n=1'-0' NORTH ���� 1 M• (FF- DRAWN BY: G B PLANS PREPARED BY: 401 W. KETTLEMAN LN. & SOUTH LEE AVE. <br /> E 014840 A CHECKED BY: A & S ENGINEERING LODI, CALIFORNIA <br /> EXP. 6-30-99 1 , R.M.L. PLANNING ENGINEERING CONSTRUCTION MANAGEMENT <br /> SCALE: S.S. # <br /> 0 2 4 6 8 10 12 * * PROJECT NO. 207 W. ALAMEDA AVENUE, SUIfrE 203 1 4 =1'-0„ 513 x <br /> 1/4°=1 '-0” �F�FCTR�GQ ,c 97141WE, PHONE: 91502 DATE: <br /> 818-842-3760 DATE: DRAWING N0. <br /> SCALE FEET qrf o� 7-30-97 E-3 a <br /> OF CALIF FILE N0. OF <br /> 97141113 SHEET Iq 2q <br />
The URL can be used to link to this page
Your browser does not support the video tag.