My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
420
>
2300 - Underground Storage Tank Program
>
PR0231906
>
COMPLIANCE INFO 2001-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/8/2021 1:08:13 PM
Creation date
11/5/2018 3:42:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2010
RECORD_ID
PR0231906
PE
2361
FACILITY_ID
FA0003776
FACILITY_NAME
KWIK SERV*
STREET_NUMBER
420
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06202042
CURRENT_STATUS
01
SITE_LOCATION
420 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\420\PR0231906\COMPLIANCE INFO 2001-2010.PDF
QuestysFileName
COMPLIANCE INFO 2001-2010
QuestysRecordDate
5/19/2017 11:33:18 PM
QuestysRecordID
3391364
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P. Ian -Tank Gauging / SIR Equipment: <br />id Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Cmmnlete the following eherkliste - <br />❑ Yes <br />❑ <br />No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />❑ Yes <br />❑ <br />No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />❑ Yes <br />❑ <br />No* <br />Was accuracy of system product level readings tested? <br />❑ Yes <br />❑ <br />No* <br />Was accuracy of system water level readings tested? <br />❑ Yes <br />❑ <br />No* <br />Were all probes reinstalled properly? <br />❑ Yes ❑ No* Were all items on the equipment manufacturer's maintenance checklist completed? <br />* T.. sl... CenHn..II 6d..... A-..... _:L.. L _� .� .�___ �..• .._ _ _ <br />--- ------------ --o ---- ••, .--�-• •••.• ..........v n..cu .u..uc um�ucum . W cf e us W UI Ue correcteU. <br />G. Line Leak Detectors (LLD): <br />. <br />Cmmnlete the following checklist <br />❑ Check this box if LLDs are not installed. <br />Yes <br />❑ No* <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br />❑ N/A <br />(Check all that apply) Simulated leak rate: Of 3 g.p.h.; ❑ 0.1 g.p.h ; ❑ 0.2 g.p.h. <br />® Yes <br />❑ No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />® Yes <br />❑ No* <br />Was the testing apparatus properly calibrated? <br />Yes <br />❑ No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />❑ N/A <br />❑ Yes <br />❑ No* <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />® N/A <br />❑ Yes <br />❑ No* <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled <br />IN N/A <br />or disconnected? <br />LiNo* <br />For electronic LLDs, does the turbine automatically shut off. if any portion of the monitoring system malfunctions <br />® N/A <br />or fails a test? <br />E <br />❑ No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />93 N/A <br />❑ No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />-.• •1, nc-.0 W, .,—" 1 V nuW anu Woen mese deficiencies were or will be corrected. <br />H. Comments: <br />Page 3 of 3 03ro1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.