COMPLIANCE INFO 2006 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
COMPLIANCE INFO 2006 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 4:57:32 PM
Creation date
11/5/2018 3:55:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006 - 2007
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\K\KETTLEMAN\800\PR0231349\COMPLIANCE INFO 2006 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2006 - 2007
QuestysRecordDate
2/16/2018 6:39:17 PM
QuestysRecordID
3798594
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FROM ' • • <br /> Magnetostrictive Probes for <br /> TLS Tank Monitoring <br /> c ertified performance for inventory control and in-tank leak <br /> detection in gasolines, diesel and a wide variety of other <br /> napproved fluids. <br /> ► Highly accurate Magne- series 8473 MAG 2 Probe <br /> tostrictive measurement The MAG 2 probe provides the same reliable inventory <br /> technology control features and fluid compatibility as the MAG 1 <br /> I ► Fast, accurate leak tests probe, but offers 0.2 GPH leak detection at a lower cost. <br /> It offers MAG probe performance with 0.2 GPH monthly <br /> ► MAG 1(0.1 GPH)and monitoring capability. <br /> MAG 2(0.2 GPH)probes <br /> available <br /> ► MAG 1 probe third-party The MAG 2 probe has also been third-parry tested <br /> certified to exceed U.S. and certified to exceed U.S. E.P.A. standards for 0.2 <br /> E.P.A. performance <br /> G.P.H automatic tank gauging. See the summary of leak <br /> standards for 0.1 GPH test performance on back or call us for a copy of the <br /> Volumetric Tank Tight- complete test results. <br /> ness Testing <br /> ► Mag 1 probe compatible MAG 1 Probe and the TLS-350 with CSLD— <br /> with TLS-350 and TLS- Leak detection without shutting down ymir P,waks! <br /> 35OR with CSLD for CSLD, Continuous Statistical Leak Detection, is a new, <br /> continuous statistical advanced tank testing technology that makes full use of <br /> leak detection the TLS-350 and TLS-350R's in-tank monitoring capa- <br /> ► MAG 2 probe third-party bilities. CSLD eliminates the need for tank shutdown to <br /> certified to exceed U.S. perform a leak test—no lost business, no lost <br /> E.P.A.performance operating time! <br /> standards for 0.2 <br /> GPH Automatic Tank The TLS-350 and TLS-350R equipped with CSLD use <br /> Gauging the MAG 1 probe to continuously monitor fuel height and <br /> ► Compatible with temperature information to detect idle times in the tank. <br /> gasolines, diesel and During each idle time, data are collected and combined <br /> other approved fluids with information from other idle periods to form a highly <br /> MAG 1 MAG 2 to. Water measurement accurate leak detection database. Sophisticated statisti- <br /> capability cal analysis techniques in CSLD constantly evaluate the <br /> database to discard invalid data and perform leak tests <br /> ► 2"and 4"Float Kits available based on only high-quality information in the current <br /> database. In fact, a new leak test is performed every time <br /> Series 8473 MAG 1 Probe new data from an idle period is added. <br /> The MAG 1 probe provides highly accurate,trouble-free <br /> performance in gasolines, diesel and a wide variety of It's the next generation in leak detection technology <br /> approved fluids. Its magnetostrictive technology and five- made possible, in part, by the accuracy of the <br /> point temperature sensing make it capable of extremely MAG 1 probe! <br /> accurate inventory control and in-tank leak testing. <br /> The MAG 1 probe has been third-party tested and Approved for Aboveground Tank Applications <br /> certified to perform far better than the U.S. E.P.A. Veeder-Root Magnetostrictive Probes are approved for <br /> standards for both 0.1 GPH volumetric tank tightness use in aboveground storage tanks to monitor fuel inven- <br /> testing and 0.2 GPH automatic tank gauging. See the tory. An AST Installation Kit(Form Number 312020-984) <br /> summary of leak test performance on back or call us for is required for these applications and is available from <br /> a copy of the complete test results. Veeder-Root or your authorized Veeder-Root distributor. <br />