My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1995
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
INSTALL_1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 2:34:40 PM
Creation date
11/5/2018 4:35:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1995
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\INSTALL 1995.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Pre tion and Installation Instruction* <br /> GiflbarcoEAIC Basonitoring Console <br /> 4. Attach the probe cable connector to the mating plug on CAUTION: IF MORE THAN TWO WIRE NUT <br /> the top;of the probe. Be sure the connector is attached CONNECTIONS SHARE AN EPDXY SEALANT <br /> securely by hand tightening the locking ring. BAG, THE CONNECTIONS WILL RESULT IN <br /> INACCURATE PROBE READINGS AND POSSI-.,,_) <br /> 6. Place floats at bottom of probe before standing the BLY FALSE ALARM CONDITIONS. <br /> probe on end. <br /> i.. � NOTE: Using epoxy sealant furnished with each <br /> jj- CAUTION: HANDLE PROBES CAR.EFULLY1 probe,seal wire nut connections using the epoxy kit <br /> STRIKING OR DROPPING PROBE WILL RESULT provided with each probe. <br /> IN LOSS OF CALIBRATION AND COULD CAUSE WARNING: EPDXY SEALANT MAY BE IRRI- <br /> PERMANENT DAMAGE. -W TATING TO EYES AND SKIN. MAY CAUSE <br /> 6. Carefully lower probe into the riser pipe until the boot SKIN SENSITIZATION IN SUSCEPTIBLE IN- <br /> rests on the bottom of the tank. DIVIDUALS.MAYBE ABSORBED THROUGH <br /> THE SKIN. EPDXY SEALANT CONTAINS EP- <br /> CAUTION:DO NOTALLOW PROBE TO FREEFALL I OXY RESIN AND VINYL CYCLOHEXENE DI- <br /> AND/OR SHARPLY IMPACTTHE BOTI'OM OF THE OXIDE.VINYL CYCLOHEKENE DIOXIDE HAS <br /> TANK SHOCK TO THE PROBE FOOT WILL RE- +` CAUSED SKIN CANCER 1N ANM AL TESTS. <br /> SULT IN SEVERE PROBE DAMAGE. fi <br /> PRECAUTIONS:AVOID EYE AND SKIN CON- <br /> T. Cut a length of flexible conduit leaving enough Mack TACT. WEAR IMPERVIOUS GLOVES AND <br /> to remove the riser cap. SAFETY GLASSES.USE ONLY IN WELL VEN- <br /> 8. Remove cable bushing nut. Feed the two-wire probe I TILATED AREAS. <br /> cable up through the riser pipe cap bushing and 13. Tighten the cable bushing nuts on the probe riser cap <br /> adaptor.(See Figure 26,"Riser Pipe Cap Bushing and and junction box to ensure a water-tight seal at the <br /> Adaptor.") probe cable entry. (See Figure 28, "Junction Box <br /> 9. Connect the adaptor to the cable bushing but do not Liquidtight Connector."J <br /> tighten. <br /> 10. Continue to feed the cable through the conduit and <br /> conduit connectors. Leave enough slack in the cable <br /> between the cap and junction box to allow the cap to - -- <br /> easily reach the riser pipe. In addition, leave enou'rh <br /> slack under the riser cap to allow the probe to rest on I box <br /> the bottom of the tank. `. <br /> 11. Using wiring nuts,connect wires from the probe cable <br /> to the probe field wires in the junction box i see Figure <br /> 27). Be sure to observe proper polarity between theCC 'Ca <br /> probe and monitor wiring during installation. The '° E' <br /> conduit must be properly sealed in accordance with <br /> the National Electrical Code (NFPA 70) and the <br /> Automotive and Marine Service Station Code iNFPA <br /> 30A) sincethey pass from a Class 1, Division I or <br /> Division II area into a non-hazardous area. <br /> Figure 29. Junction Box Liquidtight Connector <br /> JUNG tERN BOX 14. Secure the riser lockingca to the to of the riser pipe. <br /> JUNCTION 0011 cap P P P <br /> PER PROBE) a padlock mai• be installed for added security. <br /> 2 RIGtO <br /> CONOU11 ere <br /> • <br /> TOTo <br /> MomTOR PAOBE <br /> Wnt <br /> Figure 27. Tyvo-Wire Probe Field Wiring Installation Diagram <br /> 12. Seal wire nuts with epoxy sealant using one bag for <br /> two wire nut connections.(Refer to Figure 24.-Epoxy <br /> Sealant for Two-Wire Connections.") <br /> 18 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.