My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:43:39 PM
Creation date
11/5/2018 4:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2015
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO 2014 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />Wait time between applying water <br />and starting test: <br />6. PIPING <br />Test Method Developed BY: <br />❑ Sump Manufacturer <br />Initial Reading (Ri): <br />❑ Other (Specify) <br />Test Method Used: <br />j Pressure <br />Final Reading (RF): <br />❑ Other (Specie) <br />Test Equipment Used: Caldwell Level Change Indicator <br />30 Minutes <br />Sump # 1-87 <br />Sump Diameter: <br />1 ,, <br />Sump Depth: <br />40" <br />Sump Material: <br />Fiberglass <br />Height from Tank Top to Tap of <br />15" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest <br />17„ <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Dry <br />Portion of Sump Tested' <br />Wat�19 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />Yes <br />product and water)?' <br />Turbine shutdown response time <br />Not Alarmed <br />Is system programmed for fail-safe <br />Yes <br />shutdown?* <br />Was fail-safe verified to be <br />No <br />Wait time between applying water <br />and starting test: <br />5 Minutes <br />Test Start Time: <br />10:15 <br />Initial Reading (Ri): <br />•001 <br />Test End Time: <br />10:45 <br />Final Reading (RF): <br />.001 <br />Test Duration: <br />30 Minutes <br />Change in Reading (RF-Ri): <br />0 <br />Pass/Fail Threshold or Criteria: <br />005/30 Minutes <br />Pass <br />Yes <br />Test Results <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes <br />• <br />REC41VEE <br />Page <br />TESTING FEB <br />❑ Industry Standard X Professiol�a�I q + <br />IL��.. 11CVVDARrg1`1R <br />❑ Vacuum X Hydrostatic <br />Equipment Resolution:.002 <br />Sump # 2-91 Sump 0 3 -Diesel Sump # <br />42" 42" <br />40" 40" <br />Fiberglass Fiberglass <br />15" 15" <br />16" 16" <br />Dry Dry <br />Water Line 18" Water Line 18" <br />Yes I Yes <br />Not Alarmed Not Alarmed <br />Yes Yes <br />No 6 No <br />5 Minutes <br />5 Minutes <br />10:30 <br />11:10 <br />.001 <br />.001 <br />11:00 <br />11:40 <br />.001 <br />.001 <br />30 Minutes <br />30 Minutes <br />0 <br />0 <br />.005/30 Minutes <br />,005/30 Minutes <br />Pass <br />Pass <br />Yes <br />Yes <br />Yes <br />Yes <br />Comments — (include information on repairs made prior to testing, and recommended follow-Iip fpr failed tests) <br />If the entire depth of the sump is not tested, specify how much was tested. If the answer to a� of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.