My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2014 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
140
>
2300 - Underground Storage Tank Program
>
PR0505687
>
COMPLIANCE INFO 2014 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 1:43:39 PM
Creation date
11/5/2018 4:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2015
RECORD_ID
PR0505687
PE
2361
FACILITY_ID
FA0006943
FACILITY_NAME
LATHROP GAS & FOOD INC
STREET_NUMBER
140
Direction
E
STREET_NAME
LATHROP
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19611007
CURRENT_STATUS
01
SITE_LOCATION
140 E LATHROP RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\140\PR0505687\COMPLIANCE INFO 2014 - 2015.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AL <br />AL <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.orglehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />LATHROP GAS & FOOD INC <br />Facility Address: <br />1 140 E LATHROP RD, LATHROP <br />Date: <br />December 16, 2014 <br />UST System Observations <br />322 <br />CCR 2636(f)(2) Line leak detector not installed <br />❑ V ❑ R ❑ COS <br />323 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V ❑ R ❑ COS <br />324 <br />CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty <br />❑ V u R u COS <br />325 <br />CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons <br />u V u R u COS <br />326 <br />CCR 2635(b)(2) Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />n V o R o COS <br />327 <br />HSC 25283.5 Unburied below grade UST failed to meet exemption status <br />❑ V o R o COS <br />328 <br />CCR 2717.1(g) Tampered with red tag <br />u V u R u COS <br />329 <br />CCR 2717.1(f) Deposited petroleum into a red tagged UST <br />❑ V ❑ R ❑ COS <br />330 <br />HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms <br />, V ❑ R u COS <br />331 <br />CCR 2631.1 UST system not compatible with the substance stored <br />❑ V u R u COS <br />332 <br />HSC 25298(b) Failed to comply with temporary closure requirements <br />n V n R ❑ COS <br />333 <br />HSC 25298(c) Failed to comply with permanent closure requirements <br />n V ❑ R n COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />u V ❑ 'R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />u V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 See below <br />Unlisted Administration/Documentation violation <br />u V ❑ R L COS <br />2030 See below <br />Unlisted Operations/Maintenance violation <br />u V u R - COS <br />2060 See below <br />Unlisted Design/Construction violation <br />❑ V u R n COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # Remarks <br />309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />The Bravo box float and chain for the 87 and 91 products in the 11!12 UDC sump failed to stop the flow of product at <br />the dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or <br />stop the flow of product at the dispenser when it detects a leak. The service technician cleaned the float mechanism. <br />The float appears to be rubbing * around the edges on rough/bubbling paint. Notified Jessie of concerns from <br />technician for future failures. <br />Corrected on site. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by January 16, 2015. Note violation was corrected on site. <br />Consent to perform the inspection, take photos and collect samles was given by Jessie Singh, owner. This <br />ecety d y initisInspector: <br />MICHELLE HENRY, Senior REHS N* <br />one: <br />(209) 468-3454 <br />Date: <br />12!1612014 <br />pane A A <br />
The URL can be used to link to this page
Your browser does not support the video tag.