Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the state of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br />monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br />The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: Lathrop Chevron <br />Bldg. No.: <br />Site Address: 140 Lathrop Rd. <br />City: Lathrop Zip: 95330 <br />Facility Contact Person: Owner -Jesse <br />Contact Phone No.: (209) 982-5005 <br />Make/Model of Monitoring System: Gilbarco EMC <br />Date of Testing/Servicing: 12/16/2013 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment ins ected/serviccd: <br />Tank ID: #1 -Regular <br />Tank ID: #2 -Supreme <br />Z In -Tank Gauging Probe. Model: PA02650960100-87 <br />Z In -Tank Gauging Probe. Model: PA02650960100-87 <br />Z Annular Space or Vault Sensor. Model: PA02591144000 <br />Z Annular Space or Vault Sensor. Model: PA02591144000 <br />Z Piping Sump I Trench Sensor(s). Model: 794380-208 <br />Z Piping Sump I Trench Sensor(s). Model: 794380-208 <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />Z Mechanical Line Leak Detector. Model: VMI LD2000 <br />® Mechanical Line Leak Detector. Model: VMI LD2000 <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model- <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2}. <br />Tank ID: #3 -Diesel <br />Tank ID: # <br />Z In -Tank Gauging Probe. Model: PA02650960100-87 <br />❑ In -Tank Gauging Probe. Model: <br />Z Annular Space or Vault Sensor. Model: PA02591144000 <br />❑ Annular Space or Vault Sensor. Model: <br />® Piping Sump / Trench Sensor(s). Model: 794380-208 <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensar(s). Model: <br />Z Mechanical Line Leak Detector. Model: VMI LD2000 <br />❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill I High -Level Sensor. Model: <br />❑ Other (spccify equipment type and model in Section F, (11, Page 2). <br />❑ Other (specify equipment type and model in Seelion E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />(� Shear Valve(s). <br />Z Shear Valve(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />Z Shear Valve(s). <br />® Shear Valve(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />nser ID: 9-10 <br />Dispenser ID: 11-12 <br />penserContainmentSensor(s). Model:❑Dispenser <br />rD <br />Containment Sensor(s). Model: <br />earValve(s). <br />Z Shear Valve(s). <br />spenser Containment Float(s) and Chain(s). <br />Z Dispenser Containment Float(s} and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (cheek all that apply): ❑ System set-up Z Alarm history report <br />Technician Name (print): _Jeff Conger Signature: �~ <br />Certification No.: A22219 License. No.: ICC# 1801782 UT CSLB# 894932 <br />Testing Company Name: Pinnacle Fuel Compliance Services, Inc. Phone No.: (408) 206-9840 <br />Testing Company Address: P.O. Box 32849 San Jose, CA 95152-2849 Date of Testing/Servicing: 12/16/2013 <br />Page 1 of 3 <br />