I MONITORING SYSTEM CERTIFICATION IL " I " `'"I <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 JAN 0 4 2016 <br />CERTIFICATION /TEST DATE: December 17, 2015 <br />At. FACILITY <br />NER HEALTH DEPARTMENT <br />Name <br />Colonial Energy #40135 <br />Colonial Energy, LLC. <br />Address <br />192 Lathrop Road, Lathrop, CA 95330 <br />EAd,"I.7s <br />2860 N. Santiago Blvd. 2nd Floor, Orange, CA 92867 <br />Phone# <br />209-858-4998 <br />❑ <br />714-761-5426 <br />Contact <br />Station Manager <br />Victor Hassan <br />Annular Space or Vault Sensor <br />Model: <br />0794390-420 <br />Dispenser Containment Sensor(s) Model: 0794380.208 <br />A3. C U P A <br />Model: <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />0 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Victoria McCarthney <br />Contact <br />Veronica Freitas <br />Phone # <br />209.468.8257 <br />Phone # <br />916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspecteNserviced) <br />61: TANKS <br />Tank #1 (Product): Gasoline - 87-1 <br />Dispenser # : 3-4 <br />Tank #2 (Product): Gasoline - 87.2 <br />Dispenser Containment Sensoria) Model: 0794380-208 <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />Shear Valves <br />❑ <br />In -Tank Gauging Probe <br />Model; <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />Annular Space or Vault Sensor <br />Model: <br />0794.190-420 <br />M <br />Annular Space or Vault Sensor <br />Model: <br />0794390-420 <br />Dispenser Containment Sensor(s) Model: 0794380.208 <br />Piping Sump/ Trench Sensor(s) <br />Model: <br />0799980.209 <br />M <br />Piping Sump/ Trench Sensor(s) <br />Model: <br />0799994209 <br />Shear Valves <br />FIII Sump Sensor(s) <br />Model: <br />6794986208 <br />❑ <br />FIII Sump Sensoria) <br />Model: <br />0799980.208 <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />Shear Valves <br />Electronic Line Leak Detector <br />Model: <br />0848484W7 <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment In Section E) <br />Model: <br />Tank #3 (Product): Gasoline - 91 <br />Tank #4 (Product): Diesel <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />Annular Space or Vault Sensor <br />Model: <br />0794990.420 <br />Annular Space or Vault Sensor <br />Model: <br />0794390420 <br />Piping Sump/ Trench Sensors) <br />Model: <br />0791980.208 <br />Piping Sump/ Trench Sensor(s) <br />Model: <br />0794384208 <br />FIII Sump Sensor(s) <br />Model: <br />0794380.208 <br />FIII Sump Sensor(s) <br />Model: <br />0799984208 <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />Electronic Line Leak Detector <br />Model: <br />08484804M <br />Electronic Line Leak Detector <br />Model: <br />0848/84001 <br />❑ <br />Tank Overfill/High-Level Sensor <br />Model: <br />❑ <br />Tank Overfill/High-Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment In Section E) <br />Model: <br />02; <br />Dispenser # : 1-2 <br />Dispenser # : 3-4 <br />E <br />Dispenser Containment Sensoria) Model: 0794380-208 <br />Dispenser Containment Sensor(s) Model: 0794380.208 <br />Shear Valves <br />Shear Valves <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />❑ <br />Dispenser Containment Float(s) and Chaln(s) <br />Dispenser # : 5-6 <br />Dispenser # : 7-8 <br />E <br />Dispenser Containment Sensor(s) Model: 0794380.208 <br />Dispenser Containment Sensor(s) Model: 0794984208 <br />Shear Valves <br />Shear Valves <br />❑ <br />Dispenser Containment Float(s) and Chaln(s) <br />❑ <br />Dispenser Contalnment Float(s) and Chaln(s) <br />Dispenser # : 9-10 <br />Dispenser # : 11-12 <br />Dispenser Containment Sensor(s) Model: 0794380408 <br />Dispenser Contalnment Sensoria) Model: 079/884208 <br />Shear Valves <br />Shear Valves <br />❑ <br />Dispenser Containment Floats) and Chaln(s) <br />❑ <br />Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment Identified In this document was Inspected/serviced In accordance with the manufacturers' guidelines. <br />Attached to this Certification is Information (e.g. manufacturers' checklists) necessary to verify that this Information Is correct and a Plot Plan showing th <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply <br />■ System set-up ■ Alarm History Report <br />WALTON <br />Signature: .�� <br />Technician /Cert#: Jessie Wadkins I B353915307886 -UT Date: DecomhCf 172015 <br />