My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2023 12:57:00 PM
Creation date
11/5/2018 4:45:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2016 - JUNE 2017.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL SPILL CONTAINER TEST REPORT <br /> TEST DATE: January 6, 2016 <br /> Al. FACILITY A2. OWNER <br /> Name Colonial Energy#40135 Name Colonial Energy, LLC. <br /> Address 192 Lathrop Road,Lathrop,CA 95330 Address 2860 N.Santiago Blvd.2nd Floor,Orange,CA 92867 <br /> Phone# 209-858-4998 Phone# 714-761-5426 <br /> Contact Station Manager Contact Victor Hassan <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering,Inc. <br /> Address 1868 E.Hazelton Avenue,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified December 23,2015 Lic# 617238 A,B,Haz <br /> Inspector Victoria McCartney Contact Veronica Freitas <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> K. SPILL CONTAINER TEST RESULTS <br /> _ Measuring Equipment Used: Lake Test <br /> Tank Number 1 1 2 3 4 <br /> Product contained Gsaollne-87.1 Gasoline-87.2 Gasoline-91 Diesel <br /> Spill container capacity (US gallons) 6 5 5 5 <br /> Spill container manufacturer OPW OPIN OPW OPW <br /> Spill container depth (inches) 12.50 12.25 12.50 13.25 <br /> Is the spill container located In a sump? Yes Yes Yes Yes <br /> Does sump have a liquid sensor installed? Yes Yes Yes Yes <br /> Condition of spill container prior to testing Dry Dry Dry Dry <br /> Portion of spill container tested Entire Entire Entire Entire <br /> Depth of water level from bottom (inches) _ 12.00 12.00 12.00 h13 <br /> Waft time for water level to stabilize (hr:min) 0:05 0:05 D:05 Test start time 10:18 10:20 10:22 Test end time 11:18 11:20 11:22 Test duration (hr:min) 1:00 1:00 1:00 Change In water level (t 0.000 Inches) 0.000 0.000 0.000 Pass/Fall threshold (0.005 inches I'%Hr.) 0.005 0.005 0.005 <br /> TEST RESULT PASS PASS PASS PASS <br /> L. COMMENTS: <br /> JAN 222918 <br /> ENVIRONMENTAI HEALTH <br /> DEPARTMENT <br /> Signature: <br /> ������ WALTON <br /> //It'JNT.ff ➢ <br /> ENGINEERING.INC. <br /> Technician: Thomas Steiger A3106018166310 Date: January 5, 2016 <br /> ©2016 Walton Engineering,Inc. <br />