My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2023 12:57:00 PM
Creation date
11/5/2018 4:45:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2016 - JUNE 2017.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL SPILL CONTAINER TEST REPORT <br /> TEST DATE: January4, 2017 <br /> A1. FACILITY A2. OWNER <br /> Name Colonial Energy#40135 Name Colonial Energy, LLC. <br /> Address 192 Lathrop Road,Lathrop,CA 95330 Address 2860 N.Santiago Blvd.2nd Floor,Orange,CA 92867 <br /> Phone# 209-858-4998 Phone# 714-761-5426 <br /> Contact Station Manager Contact Victor Hassan <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 1868 E. Hazelton Avenue,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified December 21,2016 Lic# 617238 A,B,Haz <br /> Inspector Garrett Backus Contact Veronica Freitas <br /> Phone# 209-468-3442 Phone# 916-373-1166 <br /> K. SPILL CONTAINER TEST RESULTS <br /> Measuring Equipment Used: Lake Test <br /> Tank Number WEntireEentire <br /> 3 _ _ 4 _ <br /> Product contained soline-87-2 Gasoline-91 Diesel <br /> Spill container capacity (US gallons) 5 5 <br /> Spill container manufacturer PW OPW OPW <br /> Spill container depth (Inches) .25 12.50 13.25 <br /> Is the spill container located In a sump? s Yes Yes <br /> Does sump have a liquid sensor Installed? s Yes Yes <br /> Condition of spill container prior to testing Dry Dry <br /> Portion of spill wntalner tested tire Entire Entire <br /> Depth of water level from bottom (Inches) 12.00 12.00 12.00 13.00 <br /> Wait time for water level to stabilize (hr:min) 0:05 0:05 0:05 0:05 <br /> Test start time 9:40 9:43 9:49 9:50 <br /> Test end time 10:40 10:43 10:49 10:50 <br /> Test duration (hrmin) 1:00 1:00 1:00 1:00 <br /> Change In water level (3 0.000 Inches) 0.000 0.000 0.000 0.000 _ <br /> PasslFail threshold (0.005 Inch"I'b Hr.) 0.005 0.005 - 0.005 0.005 <br /> TEST RESULT PASS PASS PASS PASS <br /> L. COMMENTS: <br /> )/1N fi 2018, <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br /> /np�� WALTON <br /> Signature: / I <br /> ENGINEERING,INC. <br /> Technician: Anthony Reyes 845115 8293772 Date: Jatluary 4 2017 <br /> ©2017 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.