Laserfiche WebLink
SYSTEM SET-UP REPORT (Page 2) <br /> T 3:91 T 4:DIESEL LEAK TEST METHOD LINE LEAK LOCKOUT SETUP <br /> PRODUCT CODE 3 PRODUCT CODE4 - - - <br /> THERMAL COEFF :.000700 THERMAL COEFF .000450 TEST ON DATE : ALL TANK LOCKOUT SCHEDULE <br /> TANK DIAMETER : 113.75 TANK DIAMETER 110.75 JAN 1. 1996 DAILY <br /> TANK PROFILE I PT TANK PROFILE I PT START TIME : DISABLED START TIME: DISABLED <br /> FULL VOL 20149 FULL VOL 12065 TEST RATE :0.20 GAL:HR STOP TIME DISABLED <br /> DURATION : 2 HOURS <br /> FLOAT SIZE: 4.0 IN. FLOAT SIZE: 4.0 IN. TST EARLY STOP:DISABLED <br /> WATER WARNING 1.0 WATER WARNING 1.0 LEAK TEST REPORT FORMAT <br /> HIGH WATER LIMIT: 2.0 HIGH WATER LIMIT: 2.0 ___ENHANCEO <br /> MAX OR LABEL VOL: 20149 MAX OR LABEL VOL: 12065 PRESSURE LINE LEAK SETU. <br /> OVERFILL LIMIT 90% OVERFILL LIMIT 90% <br /> 18134 10858 <br /> HIGH PRODUCT 95% HIGH PRODUCT 95% O 1 :87 <br /> 19141 11461 <br /> DELIVERY LIMIT : 0% DELIVERY LIMIT 1O TYP:2.0i3.DIN FIBERGLASS <br /> 0 1206 2.01N DIA LEN: 350 FEET <br /> LOW PRODUCT 2000 LOW PRODUCT 1200 <br /> LEAK ALARM LIMIT: 25 LEAK ALARM LIMIT: 25 3-DIN DIA LEN: 0 FEET <br /> SUDDEN LOSS LIMIT: 10 SUDDEN LOSS LIMIT: 10 <br /> TANK TILT 0.00 TANK TILT 0.00 LOW PRESSURESHUTDOWN RATE: 3.0 GVH <br /> PROBE OFFSET 0.00 PROBE OFFSET 0.00 LOW PRESSURE SHUT0 PSI <br /> SIPHON MANIFOLDED TANKS SIPHON MANIFOLDED TANKS T 1:87 MASTER <br /> TO: NONE TO: NONE DISPENSE MODE: <br /> LINE MANIFOLDED TANKS LINE MANIFOLDED TANKS MANIFOLDED: ALTERNATE <br /> TO: NONEIGH PRESSURE <br /> TO: NONE _PRESSUREHOFFSET; O.OPS1 <br /> LEAK MIN PERIODIC: 0: 8 2:91 <br /> LEAK MIN PERIODIC: Os: <br /> 0LEAH MIN ANNUAL O TYP:2.DIG.01N FIB b ^E I V <br /> LEAK MIN ANNUAL 0: EN: 35 `V_ <br /> 0 2.OIN DIA L0 3.01N DIA LEN: 0 FEET <br /> PERIODIC TEST TYPE SHUTDOWN RATE: 3.0 GPH JAN 2 2 2018 <br /> STANDARD PERIODIC TEST TYPE LOW PRESSURE SHUTOFF:NO <br /> STANDARD LOW PRESSURE 0 PSI <br /> ANNUAL TEST FAIL ANNUAL TEST FAIL T 3:91 ENVIRONMENTAL HEALTH <br /> ALARM DISABLED ALARM DISABLED DISPENSE MODE: DEPARTMENT <br /> PERIODIC TEST FAIL STANDARD <br /> ALARM DISABLED PERIODIC TEST FAIL SENSOR: HIGH PRESSURE <br /> ALARM DISABLED PRESSURE OFFSET: O.OPSI <br /> GROSS TEST FAIL GROSS TEST FAIL G 3:DIESEL <br /> ALARM DISABLED ALARM DISABLED <br /> ANN TEST AVERAGING: OFF TYP:2.0/3.01N FIBERGLASS <br /> PER TEST AVERAGING: OFF ANN TEST AVERAGING: OFF 2.01N DIA LEN: 400 FEET <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFFTANK TEST NOTIFY: OFF 3.01N DIA LEN: 0 FEET <br /> TNK TST SIPHON BREAK:OFF SHUTDOWN RATE: 3.0 GPH <br /> TNK TST SIPHON BREAKOFF LOW PRESSURE SHUTOFF:NO <br /> DELIVER`! DELAY 5 MIN DELIVERY DELAY : 5 MIN LOW PRESSURE 0 PBI <br /> PUMP THRESHOLD 10.00% PUMP THRESHOLD : 10.00, T 4:DIESEL <br /> DISPENSE MODE: <br /> STANDARD <br /> SENSOR: HIGH PRESSURE <br /> PRESSURE OFFSET: O.OPSI <br /> ©201]Walton Engineering,Inc. <br />