Laserfiche WebLink
MONIT . ING SYSTEM CERTI r..ATION <br />MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS-350 <br />JAN 21 2014 <br />CERTIFICATION /TEST DATE: Januiaryl4,2014 <br />A1. FACILITY <br />Name <br />A2. OWNER NTAt HL:fti- <br />Tower Mart # 104 <br />^ ' <br />Name Tower Energy Group, Inc. `RMI71SERVIC,a- <br />Address 192 Lathrop Road, Lathrop, CA 95330 <br />Phone # 209-8584998 <br />Address 1983 West 190th Street, Torrance, CA 90504 <br />Contact Desiz Bums <br />Phone # 916-285-7402 ext 100 <br />Contact Mark Vasey <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Address 1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Name Walton Engineering, Inc. <br />Notified January 7, 2014 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Lic # 617238 A, B, Haz <br />Inspector Jeff Wong <br />Contact Dulcinea Coven <br />Phone # 209468-8257 <br />Phone # 916-373-1166 <br />B. INVENTORY OF EQUIPMENTTESTED/CERTIFIED <br />(Check the <br />appropriate boxes to Indicate equipment inspected/serviced) <br />_ B1: TANKS <br />-- <br />rTank <br />Tank #2 (Product): Gasoline87-2 - <br />#1 (Product): Gasoline - 87-1 <br />❑ In-Tank Gauging Probe Model: <br />❑ In-Tank Gauging Probe Model: <br />or <br />■ Annular Space or Vault Sensor Model: 0794390420 <br />■ Annular Space or Vault Sensor Model: 0784390420 <br />■ Piping Sump / Sensor(s) Model: _0784380.208 <br />■ Piping Sump / Trench Sensor(s) Model: 0794380.208 <br />■ Fill Sump Sensoria) Model: 0794380.208 <br />■ Fill Sump Sensor(s) Model: 0784380.208 <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />■ Electronic Line Leak Detector Model: 0848480-001 <br />Line Leak Detector MotleModel;ElTank <br />Overfill / High-Level Sensor Model: <br />El Tank <br />Tank Over ill / High-Level Sensor Model: <br />El Other (specify equipment in Section E) Motlel: <br />L Other (specify equipment in Section E) Model: <br />_ _� <br />Tank #3 (Product): Gasoline .9i <br />_ Tank #4 (Product): Diesel <br />❑ In-Tank Gauging Probe Model: <br />❑ In-Tank Gauging Probe Motlel <br />■ Anular Space or Vault Sensor Model: 0794390420 _ <br />■ Piping Sump /Trench Sensorial Model: 0794380.208 <br />■ Annular Space or Vault Sensor Model' 0784390420 <br />■ Piping Sump / Trench Sensoria) Motlel: 0794380.208 <br />■ Fill Sump Sensor(s) Model: 0794380.208 <br />■ Fill Sump Sensor(s) Model: 0784980-208 <br />❑ Mechanical Line Leak Detector Model: <br />❑Mechanical Line Leak Detector Model: <br />■ Electronic Line Leak Detector Model: 0849480-M <br />■ Electronic Line Leak Detector Model: 0848480-001 <br />❑ Tank Overfill / High-Level Sensor Model- <br />❑ Tank Overfill / High-Level Sensor Model: <br />_ ❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />B2: DISPENSERS/UDC's <br />Dispenser# 1-2 - Dispenser#: -3-4- - <br />■ Dispenser Containment Sensor(s) Model: 0784380.208 ■ Dispenser Containment Sensor(s) Model: 0794380.208 <br />■ Shear Valves ■ Shear Valves <br />❑ Dispenser Containment Float(s) and Chains) ❑ Dispenser Containment Floats) and Chain(s) <br />Dispenser # : 5-6 <br />Dispenser # : 7-$ <br />■ Dispenser Containment Sensorial Model: 0784380.208 ■ Dispenser Containment Sensors) Model: 0794380.208 <br />■ Shear Valves ■ Shear Valves <br />I ❑ Dispenser Containment Float(s) � P _ and Chain(s) _._- .. _ ❑ Dispenser Containment Float(s) and Chains) <br />- <br />Dispenser#: 9-10 Dispenser#: 11-12 -- <br />■ Dispenser Containment Sensor(s) Model: 0784380.208. ■ Dispenser Containment Sensor(a) Model: 0794380.208 <br />■ Shear Valves ■ Shear Valves <br />❑_ Dispenser Containment Float(s)and Chain(s) <br />— _ ❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected1serviced In accordance with the manufacturers' <br />Attached <br />guidelines. <br />to this Certification Is information (e.g. manufactures' checklists) necessary to verify that this Information is correct Plot <br />and a Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ S stem set-up ■ Alarm History Report <br />11 ` pp/p <br />I �,.��eP_ WALTON <br />fl�l 9 _ <br />Signature: JJ 1 <br />Technician / Cert#: Jessie Wadkins / B35391 5307886-UT Date: January 14, 2014 <br />w avta Walton Engineering, Inc. <br />