My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/5/2018 4:46:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />CONTINUATION FORM <br />Page: 4 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 01/16/13 <br />Facility Address: Tower Mart #104 192 Lathrop Road, Lathrop <br />Program!: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Com <br />204. DO failed to document correct test dates. In DO Jan 2013, October - November 2012 reports, the <br />DO noted the secondary containment (2CT) testing as 09115/09. Thus 2CT is past due since the tri- <br />ennial testing should have been due by 09/2012 and DO failed to notify operator of past due testing. A <br />copy of the recent 2CT test result were found and test was performed on 10/23112. DO should have <br />documented the recent test dates on the DO monthly reports starting in October 2012 to present. During <br />the monthly inspection, the designated operator shall check that all required testing and maintenance for <br />the UST system have been completed and document the dates they were done. Ensure that designated <br />operators performing monthly inspections at this facility are including all of the required information on <br />the reports. Submit a statement how DO would ensure correct dates are documented and how past DO <br />monthly reports would be corrected. <br />108. Secondary containment testing was last performed on 09/15/09 and was completed on 10/23/12, <br />one month past due. Secondary containment testing is required once every 36 months. Take all <br />necessary precautions to ensure testing is performed in a timely manner. Submit a statement how to <br />ensure next 2CT is done in a timely manner. Next due by 10/2015. <br />313. All spill containers, 87 Master, 87 Siphon, 91 and diesel, all had approximately 1/4 to 1/2 full of <br />liquid in the buckets. All spill containers shall have a minimum capacity of five gallons and be capable of <br />containing a spill or overfill until it is detected or cleaned up. Immediately remove any liquid in the spill <br />bucket into the appropriate hazardous waste container. The DO is responsible for inspecting spill <br />buckets, documenting and notifying operator if there is any liquid that needs to be removed. Store <br />employees should check the spill bucket prior to any fuel delivery. No fuel deposition should be allowed <br />if there is liquid in the spill bucket as the spill bucket is not prepared to contain a minimum of 5 gallons of <br />spill fuel during an accident. Submit a statement how to ensure spill buckets will be maintained empty at <br />times. <br />Submit to SJC EHD within 30 days (02116/13): <br />1. one copy of the completed "Return to Compliance Certification" form <br />2. a written corrective action statement for each of the above violations <br />Note: - Provided: HW labeling instruction, CERS flyer, CERS Lead User Autho form, RTC Cert form <br />- DO documented a December 18, 2012 monthly report with an alarm history printout attachment of the <br />same date. In the same report, he had documented a future alarm of 12/22/12 L2: 87 slave STP sump <br />fuel alarm although the 12118/12 alarm history printout could not have recorded this alarm. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Inspector <br />Thuy Tran (209) 468-8257 <br />Received -.5y: <br />r <br />Title: <br />EHD 23-02-003 Rev 04119/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.