L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO 2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:19 PM
Creation date
11/5/2018 4:46:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LATHROP\192\PR0505867\COMPLIANCE INFO 2013-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITWING SYSTEM CERTIF&ATION <br />MAKE/ MODEL OF MONITORING SYSTEM: Veeder-Root TLS -350 <br />CERTIFICATION /TEST DATE: March 5, 2014 <br />Al. FACILITY <br />A2. OWNER <br />Name Tower Mart # 104 <br />Name Tower Energy Group, Inc. <br />Address 192 Lathrop Road, Lathrop, CA 95330 <br />Address 1983 West 190th Street, Torrance, CA 90504 <br />Phone# 209-858-4998 <br />Phone# 916-285-7402 ext 100 <br />Contact Desiz Burns <br />Contact Mark Vasey <br />A3. C UP A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified February 25, 2014 <br />Lic # 617238 A, B, Haz <br />Inspector Elena Manzo <br />Contact Dulcinea Covan <br />Phone# 209-468-8257 <br />Phone# 916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (check the appropriate boxes to Indicate equipment inspected/serviced) <br />B1: TANKS <br />Tank #1 (Product): Gasoline - 87 M <br />Tank #2 (Product): Gasoline -87S <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump I Trench Sensors) Model: <br />❑ Piping Sump / Trench Sensoria) Model: <br />❑ Fill Sump Sensoria) Model: <br />❑ Fill Sump Sensor(s) Madel: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />''� ❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />Tank #3 (Product): Gasoline - 91 Tank #4 (Product): Diesel <br />❑ In -Tank Gauging Probe Model: ❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: 1 ❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump I Trench Sensor(s) Model: ■ Piping Sump / Trench Sensoria) Model: 0794380-208 <br />❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill I High -Level Sensor Model: ❑ Tank Overfill I High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br />B2: DISPENSERS/UDC's <br />Dispenser # : Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensoria) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Floats) and Chain(s) <br />Dispenser # : <br />Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensoria) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : <br />Dispenser # <br />❑ Dispenser Containment Sensors) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves <br />❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chafn(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm Histo Report <br />,, ^^ <br />(0 %% I �/I �J/1 WALTON <br />Signature: './' C(y�y,((/ NGINc EFING, MC. <br />Technician I Cert #: Chris Kuykendall / B42243 8161927 Date: March 5, 2014 <br />