Laserfiche WebLink
CIRCUITS FROM PROVIDE (2)2"X4" BLOCKING, LAID L E G E N D El <br /> M€93 d <br /> PANEL SEE RELAY FIAT SPACELUU TO MATCH MOUNTING �__ FLUORESCENT LIGHT FIXTURE, RECESSED MOUNT CAP. LETTER=T WPITEC a <br /> SCHEDULE FOR HOLES IN LIGHT FIXTURE BODY. WOOD CEILING JOIST. <br /> 3-CONDUCTOR LOW ACTUAL clRculrs I FLUORESCENT LIGHT FIXTURE, SURFACE MOUNT SM. LETTER=SWITCHING A <br /> �W� <br /> VOLTAGE CABLE LOW VOLTAGE RELAYS. "' ,:� ® CEILING LIGHT FIXTURE NUMBER=CIRCUIT <br /> IN CONDUIT SEE RELAY SCHEDULE <br /> FOR ACTUAL NUMBER FASTEN WOOD BLOCKING , © RECESSED LIGHT FIXTURE <br /> HOF RELAYS 0 WOOD JOIST USING :---i ' a @I WALL BRACKET LIGHT FIXTURE �'m8 °16d NAILS TvLOW VOLTAGE RELAY EACH ENDS - h --- - - - — ® LIGHT FIXTURE ON EMERGENCY POWER CIRCUIT WITH INTEGRAL EMERGENCY BATTERY PACK �CONTROL CABINET t} FASTEN FIXTURE TO WOOD ® LIGHT FIXTURE ON EMERGENCY POWER CIRCUIT WITH INTEGRAL EMERGENCY BATTERY PACKTj�1SEE BELOW FOR FINISHED I�J LOCKING WITH 112X2" RHWS �W W wRELAY SCHEDULE CEILING I TOTAL OF 4 PER FIXTURE) ® RECESSED LIGHT FIXTURE POWER CIRCUIT WITH INTEGRAL EMERGENCY BATTERY PACKHAF14TYPICAL SURFACE MOUNT A EXIT LIGHT-HIGH LEVEL 11 � Fom°FLUOR. FIXTURE ALTERNATE DESIGNATION OF LIGHT FIXTURE SHOWING TYPE & LAMPS OLOW VOLTAGE - " —� INTERIOR LIGHTS LIGHT SWITCH - SPST UP 48" U.O.N. FLUSH SWITCHES — CONTROLLED IN INDIVIDUAL $' LIGHT SWITCH - 3-WAY <br /> ROOMS. FIXTURE INSTALLED AT 90° TO JOISTS DIMMER SWITCH Asa <br /> ALSO SERVES <br /> AS MANUAL c---" ® OCCUPANCY SENSOR LIGHT SWITCH <br /> OVERRIDE SWITCH FAM OCCUPANCY SENSOR LIGHT SWITCH W/MANNUAL SWITCH <br /> >:Ev 120 VOLT DUPLEX WALL OUTLET FOR VIEWBOX <br /> --er 120 VOLT DUPLEX WALL OUTLET UP 18" U.O.N. <br /> PROVIDE 4"X4 BLOCKING 120 VOLT FOURPLEX OUTLET b <br /> (TOTAL OF 2 PER FIXTURE) /—WOOD CEILING JOIST. ffi 120V DUPLEX OUTLET MOUNTED AT +42" A.F.F. OR +4" ABOVE <br /> COUNTERTOP AS APPLICABLE V) <br /> FASTEN WOOD BLOCKING I ' ;. ® SPECIAL PURPOSE OUTLET. TYPE & RATING TO SUIT LOAD SERVED <br /> TyqOWOOD J01 T USING II 120V DUPLEX OUTLET, HALF-SWITCHED, +18" A.F.F. U.O.N., FLUSH Ld <br /> 21 EACHAEND.ILS OTAL OF - ' <br /> 120V DUPLEX OUTLET ON EMERGENCY POWER CIRCUIT, +18" I � <br /> (— � A.F.F. U.O.N., FLUSH z? <br /> AUTOMATIC FASTEN FIXTURE TO WOOD Z °- <br /> SHuroFF1 FINISHED o o GFI INDICATES GROUND FAULT INTERRUPTER OUTLET o <br /> LOCKING WITH 12X2" RHWS (7 - m <br /> CONTROLS CEILING t' ° �^ <br /> [TIME S'MTTCH TOTAL OF 4 PE FIXTURE) ® TELEPHONE WALL OUTLET UP 18" U.O.N. FLUSH Z a � v, <br /> — —� TYPICAL SURFACE MOUNT o COMPUTER SYSTEM WALL OUTLET UP 18" U.O.N. FLUSH <br /> CO � FLUOR. FIXTURE Ow TELEPHONE WALL OUTLET UP 54" U.O.N. FLUSH o m W <br /> NTROL ' m INTERCOM SYSTEM STATION <br /> xFMR I O JUNCTION BOX ❑ <br /> FIXTURE INSTALLED PARALLEL TO JOIST © TIME CLOCK <br /> MOTOR OUTLET MIN. SIZE=1/2"C i <br /> LOW VOLTAGELINE VOLTAGE -h�-- CONDUIT CONCEALED IN WALL OR CEILING TICS=NO OF #12 WIRES W <br /> COMPARTMENT COMPARTMENT CONDUIT WITH INSULATED GROUND WIRE NO TICS=2#12 U.O.N. <br /> MOUNTING DETAIL: - - - CONDUIT CONCEALED IN FLOOR OR UNDERGROUND UNLUND NOT ESS SS ISOLAT DOWN 1 <br /> �i FLEXIBLE CONDUIT FOR LIGHTING ABOVE CEILING V <br /> TYPICAL SCHEMATIC DIAGRAM : SURFACE FLUORESCENT FIXTURE ® DIGHRIBUTIP NEANEL V <br /> TNG LOW VOLTAGE LIGHTING CONTROLS / MAX WEIGHT = 30 LBS. 9� SIGNAL CABINET <br /> WALL EMERGENCY LAGHTD FIXTURE W/BATTERY BACKUP U in } <br /> AUTOMATIC SHUT OFF CONTROL PANEL so CEILING MOUNT FIRE ALARM SYSTEM SMOKE DETECTOR Ino <br /> ma WALL MOUNT FIRE ALARM SYSTEM HORN\STROBE LIGHT L � 4 <br /> C 10 WALL MOUNT FIRE ALARM SYSTEM STROBE LIGHT — 3 <br /> ®a WALL MOUNT FIRE ALARM SYSTEM HORN <br /> O PUSH BUTTON. FUNCTION AS INDICATED ON FLOOR PLAN N <br /> ® DOOR OPERATOR, ELECTRIC. <br /> AUTOMATIC LIGHTING SHUT OFF CONTROLS: ® LINE VOLTAGE CIRCUIT BREAKER, FLUSH <br /> SCHEMATIC DIAGRAM ® FIRE ALARM SYSTEM PULL STATION <br /> SEE ARCH. DRAWINGS & SPECS ® SMOKE/FIRE DAMPER <br /> ON "HANGER WIRE DETAIL" F9 LOW VOLTAGE MOTION SENSITIVE OCCUPANCY SENSOR, WALL MOUNT <br /> 1. CONTROL PANEL TO RE AS MANUFACTURED BY WATT STOPPER TYPE "SWS". APPROVED FASTEN #12 SUSPENSION WIRE FOR ANCHORAGE DETAIL. u® MOTION SENSITIVE OCCUPANCY SENSOR, CEILING MOUNT <br /> EQUALS ARE ILC LIGHT MASTER, LITHONIA SWITCH KEEPER AND TRIATEK "LP" SERIES. ALL AT 2 DIAGONAL CORNERS OF PROVIDE 2 TAUGHT WIRES AT © POWER PACK FOR OCCUPANCY SENSOR. MOUNT IN CEILING SPACE <br /> OTHERS REQUIRE PER-APPROVAL BY THE ENGINEER. EACH 4' LAY-IN FIXTURE & DIAGONAL CORNNERS FOR FIXTURES <br /> TO STRUCTURAL MEMBER THAT WEIGHS 56LBS OR LESS <br /> LIGHTING CONTROLS TO BE PROVIDED• <br /> PROVIDE 4 TAUGHT SUPPORT gp <br /> 7. AN AUTOMATIC SHUT OFF CONTROL SYSTEM SHALL BE PROVIDED FOR THE WIRES, ONE AT EACH CORNER � G1 <br /> INTERIOR LIGHTING OF THE AREAS NOTED ON THE PANELS IN COMPLIANCE WITH INTEGRAL EARTHQUAKE FOR FIXTURES THAT WEIGH <br /> THE ENERGY EFFICIENCY STANDARDS, TITLE 24 PART 6 SECTION 131(d). a� <br /> CLIP. BEND OUT AS MORE THAN 56 LBS. E L E C T R I C A L A B B R E V I A T 1 0 N S t <br /> AN AUTOMATIC TIME SWITCH CONTROL DEVICE SHALL BE INSTALLED TO REQUIRED TO ENGAGE �-� <br /> COMPLY WITH SECTION 131(d)1. THIS DEVICE SHALL BE PART OFA MAIN "TEE" RUNNERS. FASTEN FIXTURE TO MAIN 9 <br /> COMPREHENSIVE INTELLIGENT LIGHTING CONTROLLER, COMPLETE WITH TIMERS, 1/4" HOLE IN CLIP FOR RUNNER W/#8x1/2 SELF- A.F.G. ABOVE FINISHED GRADE <br /> KEYPAD, RELAYS, POWER SUPPLY, ETC. SUSPENSION RUNNERS TAPPING TEK SCREWS, ONE <br /> AT EACH CORNER A.F.F. ABOVE FINISHED FLOOR <br /> AN OVERRIDE SWITCHING DEVICE SHALL BE PROVIDED TO COMPLY WITH UG UNDERGROUND ��yy <br /> SECTION 131(d)2. THE LIGHTING SWITCH FOR INDIVIDUAL ROOMS AND CEILING TILE 4D <br /> AREAS SHALL ALSO SERVE AS THESE OVERRIDE DEVICES. THE ENTIRE WP WEATHERPROOF <br /> LIGHTING CONTROL SYSTEM SHALL BE WIRED AND PROGRAMMED TO MEETCO CONDUIT ONLY cz Q <br /> THE ABOVE MENTIONED REQUIREMENTS. T—BAR LAY—IN FLUORESCENT C CONDUIT <br /> 2. ALL LIGHTS SHALL BE SWITCHED ON AND OFF USING MOMENTARY ���III LIGHT FIXTURE p <br /> U.O.N. UNLESS OTHERWISE NOTED <br /> CONTACT, ON/OFF SWITCHES UNLESS OTHERWISE SHOWN. APPROVED <br /> ALTERNATES ARE DIGITAL SWITCHES. THEY SHALL ADDITIONALLY BE SWITCHED NO. NUMBER <br /> OFF AUTOMATICALLY THROUGH THE AUTOMATIC SHUT OFF CONTROL PANEL. MOUNTING DETAIL: LAY- IN FIXTURE MIN. MINIMUM <br /> 3. ALL EXIT SIGNS SHALL BE UNSWITCHED AND NOT PASS THROUGH THE MAX. MAXIMUM <br /> AUTOMATIC SHUT OFF CONTROL PANEL. A, AMP AMPERE <br /> A D W/ WITH <br /> GFI GROUND FAULT INTERRUPTER q a <br /> & AND ami <br /> (e),(E) EXISTING <br /> OCCUPANCY SENSOR, <br /> OT (R) REMOVE CZ � <br /> FY <br /> CEILING MOUNT �� (RR) REMOVE, RELOCATE AND RECONNECT AT LOCATION SHOWN � w <br /> A.I.C. AMPERE INTERRUPTING CAPACITY C > <br /> 2-GANG (- GRD. GROUND <br /> US PLATE I I_ (AUTOMATIC SENSOR V VOLT <br /> POWER PACK I SWITCH CKT. CIRCUIT <br /> "PP". MOUNT LIGHTING LOADS-FIXTURES MOTION L J KW KILOWATT <br /> WITHIN CL'G INDIVIDUALLY SWITCHED OR SENSOR <br /> SPACE U.O.N. HALF SWITCHED PER PLAN KVA KILOVOLT AMPERE <br /> PP r� HT r--� SP SPACE <br /> I MANUAL CU COPPER <br /> ON/OFF AL ALUMINUM <br /> I SWITCH LC <br /> N ��-- SWITTCH SWITCHOFF L__ J NL NIGHTNLLIIGHTCONTACTOR <br /> 2ov <br /> E:1 <br /> LIGHTS - INSIDE LIGHTS - OUTSIDE PB PULLBOX <br /> WALL LIGHT LAMPS EACH FIXTURE LAMPS EACH FIXTURE E.C. ELECTRICAL CONTRACTOR <br /> SWITCHES G.C. GENERAL CONTRACTOR <br /> P.C. PLUMBING CONTRACTOR <br /> M.C. MECHANICAL CONTRACTOR DATE 9-22-09 <br /> DRAWN BY <br /> ELEVATION SCHEMATIC DIAGRAM BA <br /> CEILING: OCCUPANCY SENSOR LIGHTING CONTROL ° NCS ENGINEERING, INC. JOBCKED BY RCS <br /> DUAL LEVEL LIGHTING, SINGLE CIRCUIT DETAIL: LIGHTING SWITCH STATION No. EId 3 CONSULTING ELECTRICAL ENGINEERS 09.012 <br /> Eap. E-30-11 * 4512 FEATHER RIVER DRIVE, SUITE F <br /> ON, CA <br /> 'FOF CALtP�rP ETT <br /> MAILAADDRE S - Be 78 <br /> na d®hcsng.com—8270 �V((�� <br /> B E F PROD.---209..LB9--DES.— WDW—ENG.--JML— <br /> OF X SHEETS <br /> FILE: K:\2009\100-199\Schock SuperLube E6.dwg Jan 21, 2010 — 12:54pm bernord <br />